Cargando…

A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device

In recent years, glaucoma tube surgery has been recommended for refractory cases that have failed to respond to angle surgery. In this study, we described the case of the fibrous proliferative membrane caused in the anterior chamber after Ahmed glaucoma valve implantation in a pediatric glaucoma pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyako, Fumiya, Kiuchi, Yoshiaki, Onoe, Hiromitsu, Okada, Naoki, Okumichi, Hideaki, Hirooka, Kazuyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9338429/
https://www.ncbi.nlm.nih.gov/pubmed/35915674
http://dx.doi.org/10.7759/cureus.26445
_version_ 1784759965683023872
author Miyako, Fumiya
Kiuchi, Yoshiaki
Onoe, Hiromitsu
Okada, Naoki
Okumichi, Hideaki
Hirooka, Kazuyuki
author_facet Miyako, Fumiya
Kiuchi, Yoshiaki
Onoe, Hiromitsu
Okada, Naoki
Okumichi, Hideaki
Hirooka, Kazuyuki
author_sort Miyako, Fumiya
collection PubMed
description In recent years, glaucoma tube surgery has been recommended for refractory cases that have failed to respond to angle surgery. In this study, we described the case of the fibrous proliferative membrane caused in the anterior chamber after Ahmed glaucoma valve implantation in a pediatric glaucoma patient. He was born full term, weighing 3228 g. Corneal opacity in both eyes was seen at birth and he was referred to the Department of Ophthalmology, Hiroshima University Hospital on the 13th day of his life. At the initial examination, the intraocular pressure was 37mmHg right 25mmHg left. Corneal diameter expansion and diffuse corneal opacity were seen in both eyes. Nine days after the initial examination, trabeculotomy was performed in both eyes but they were ineffective, and Ahmed glaucoma tubes were inserted in both eyes two months later. Four months later the intraocular pressure remained 30mmHg range in both eyes and micropulse cyclophotocoagulation was performed. One year after the Ahmed glaucoma valve implantation, the tube of right eye was exposed, and we planned to perform a repair procedure. At this time, ultrasound biomicroscopy (UBM) showed proliferative tissue around both tubes. They were removed next month. Although silicone is a highly biocompatible material, it can cause foreign body reactions such as encapsulation around the silicone plate and proliferative membranes around silicone oil. We speculated that a similar reaction occurred to the silicone tube in this case. We reported a case of fibrous proliferative membrane in the anterior chamber. This might be caused by the silicon tube of the Ahmed glaucoma valve.
format Online
Article
Text
id pubmed-9338429
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-93384292022-07-31 A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device Miyako, Fumiya Kiuchi, Yoshiaki Onoe, Hiromitsu Okada, Naoki Okumichi, Hideaki Hirooka, Kazuyuki Cureus Ophthalmology In recent years, glaucoma tube surgery has been recommended for refractory cases that have failed to respond to angle surgery. In this study, we described the case of the fibrous proliferative membrane caused in the anterior chamber after Ahmed glaucoma valve implantation in a pediatric glaucoma patient. He was born full term, weighing 3228 g. Corneal opacity in both eyes was seen at birth and he was referred to the Department of Ophthalmology, Hiroshima University Hospital on the 13th day of his life. At the initial examination, the intraocular pressure was 37mmHg right 25mmHg left. Corneal diameter expansion and diffuse corneal opacity were seen in both eyes. Nine days after the initial examination, trabeculotomy was performed in both eyes but they were ineffective, and Ahmed glaucoma tubes were inserted in both eyes two months later. Four months later the intraocular pressure remained 30mmHg range in both eyes and micropulse cyclophotocoagulation was performed. One year after the Ahmed glaucoma valve implantation, the tube of right eye was exposed, and we planned to perform a repair procedure. At this time, ultrasound biomicroscopy (UBM) showed proliferative tissue around both tubes. They were removed next month. Although silicone is a highly biocompatible material, it can cause foreign body reactions such as encapsulation around the silicone plate and proliferative membranes around silicone oil. We speculated that a similar reaction occurred to the silicone tube in this case. We reported a case of fibrous proliferative membrane in the anterior chamber. This might be caused by the silicon tube of the Ahmed glaucoma valve. Cureus 2022-06-30 /pmc/articles/PMC9338429/ /pubmed/35915674 http://dx.doi.org/10.7759/cureus.26445 Text en Copyright © 2022, Miyako et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Ophthalmology
Miyako, Fumiya
Kiuchi, Yoshiaki
Onoe, Hiromitsu
Okada, Naoki
Okumichi, Hideaki
Hirooka, Kazuyuki
A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title_full A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title_fullStr A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title_full_unstemmed A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title_short A Case of Intraocular Proliferative Changes Caused by a Glaucoma Tube Device
title_sort case of intraocular proliferative changes caused by a glaucoma tube device
topic Ophthalmology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9338429/
https://www.ncbi.nlm.nih.gov/pubmed/35915674
http://dx.doi.org/10.7759/cureus.26445
work_keys_str_mv AT miyakofumiya acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT kiuchiyoshiaki acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT onoehiromitsu acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT okadanaoki acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT okumichihideaki acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT hirookakazuyuki acaseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT miyakofumiya caseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT kiuchiyoshiaki caseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT onoehiromitsu caseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT okadanaoki caseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT okumichihideaki caseofintraocularproliferativechangescausedbyaglaucomatubedevice
AT hirookakazuyuki caseofintraocularproliferativechangescausedbyaglaucomatubedevice