Cargando…
Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates
OBJECTIVE: To investigate the application value analysis of ultrasound-guided technology in peripheral deep venous catheterization of neonates. METHOD: A total of 94 neonates who underwent peripheral deep venous catheterization treatment from March 2020 to August 2021 in our hospital were selected a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9338843/ https://www.ncbi.nlm.nih.gov/pubmed/35915734 http://dx.doi.org/10.1155/2022/1726906 |
_version_ | 1784760052871069696 |
---|---|
author | Yin, Tingting Huo, Yuan Zhao, Yang Li, Weiyang Gao, Hongxia |
author_facet | Yin, Tingting Huo, Yuan Zhao, Yang Li, Weiyang Gao, Hongxia |
author_sort | Yin, Tingting |
collection | PubMed |
description | OBJECTIVE: To investigate the application value analysis of ultrasound-guided technology in peripheral deep venous catheterization of neonates. METHOD: A total of 94 neonates who underwent peripheral deep venous catheterization treatment from March 2020 to August 2021 in our hospital were selected and divided into the study group and the control group according to the simple randomized method, and each group had 47 cases. The control group was performed peripheral deep venous catheterization through X-ray examination, while the study group was performed peripheral deep venous catheterization through ultrasound-guided technology. The catheter placement, catheter retention time and adjustment times, the incidence of complications (limb swelling, pain, fluid leakage, and phlebitis), and the intervention satisfaction of family members were counted. RESULTS: The success rate of one-time catheterization in the study group was higher than that in the control group, the operation time was shorter than that in the control group, and the amount of bleeding was less than that in the control group. The indwelling time of catheter in the study group was longer than that in the control group, and the number of adjustments was less than that in the control group. The incidence of complications in the study group was lower than that in the control group. The intervention satisfaction of family members in the study group was higher than that in the control group. CONCLUSION: Peripheral deep venous catheterization in neonates through ultrasound-guided technology can reduce operation time and blood loss and ensure the success rate of one-time catheterization, resulting in a long indwelling time of catheter, low number of adjustments, and low incidence of complications, which has safety and high intervention satisfaction of family members. |
format | Online Article Text |
id | pubmed-9338843 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-93388432022-07-31 Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates Yin, Tingting Huo, Yuan Zhao, Yang Li, Weiyang Gao, Hongxia Dis Markers Research Article OBJECTIVE: To investigate the application value analysis of ultrasound-guided technology in peripheral deep venous catheterization of neonates. METHOD: A total of 94 neonates who underwent peripheral deep venous catheterization treatment from March 2020 to August 2021 in our hospital were selected and divided into the study group and the control group according to the simple randomized method, and each group had 47 cases. The control group was performed peripheral deep venous catheterization through X-ray examination, while the study group was performed peripheral deep venous catheterization through ultrasound-guided technology. The catheter placement, catheter retention time and adjustment times, the incidence of complications (limb swelling, pain, fluid leakage, and phlebitis), and the intervention satisfaction of family members were counted. RESULTS: The success rate of one-time catheterization in the study group was higher than that in the control group, the operation time was shorter than that in the control group, and the amount of bleeding was less than that in the control group. The indwelling time of catheter in the study group was longer than that in the control group, and the number of adjustments was less than that in the control group. The incidence of complications in the study group was lower than that in the control group. The intervention satisfaction of family members in the study group was higher than that in the control group. CONCLUSION: Peripheral deep venous catheterization in neonates through ultrasound-guided technology can reduce operation time and blood loss and ensure the success rate of one-time catheterization, resulting in a long indwelling time of catheter, low number of adjustments, and low incidence of complications, which has safety and high intervention satisfaction of family members. Hindawi 2022-07-23 /pmc/articles/PMC9338843/ /pubmed/35915734 http://dx.doi.org/10.1155/2022/1726906 Text en Copyright © 2022 Tingting Yin et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Yin, Tingting Huo, Yuan Zhao, Yang Li, Weiyang Gao, Hongxia Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title | Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title_full | Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title_fullStr | Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title_full_unstemmed | Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title_short | Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates |
title_sort | retrospective study of the application value analysis of ultrasound-guided technology in peripheral deep venous catheterization of neonates |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9338843/ https://www.ncbi.nlm.nih.gov/pubmed/35915734 http://dx.doi.org/10.1155/2022/1726906 |
work_keys_str_mv | AT yintingting retrospectivestudyoftheapplicationvalueanalysisofultrasoundguidedtechnologyinperipheraldeepvenouscatheterizationofneonates AT huoyuan retrospectivestudyoftheapplicationvalueanalysisofultrasoundguidedtechnologyinperipheraldeepvenouscatheterizationofneonates AT zhaoyang retrospectivestudyoftheapplicationvalueanalysisofultrasoundguidedtechnologyinperipheraldeepvenouscatheterizationofneonates AT liweiyang retrospectivestudyoftheapplicationvalueanalysisofultrasoundguidedtechnologyinperipheraldeepvenouscatheterizationofneonates AT gaohongxia retrospectivestudyoftheapplicationvalueanalysisofultrasoundguidedtechnologyinperipheraldeepvenouscatheterizationofneonates |