Cargando…

Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?

Introduction There is still a lot of controversy and ambiguity, and no single therapy regimen or strategy for proximal humerus fractures has been proved to be uniformly helpful. According to estimates, only about 20% of proximal humeral fractures require surgery. This study aims at evaluating the fu...

Descripción completa

Detalles Bibliográficos
Autores principales: Ethiraj, Prabhu, Venkataraman, Sagar, S J, Karthik, Shanthappa, Arun H, Agarawal, Sandesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339088/
https://www.ncbi.nlm.nih.gov/pubmed/35919369
http://dx.doi.org/10.7759/cureus.26474
_version_ 1784760101840617472
author Ethiraj, Prabhu
Venkataraman, Sagar
S J, Karthik
Shanthappa, Arun H
Agarawal, Sandesh
author_facet Ethiraj, Prabhu
Venkataraman, Sagar
S J, Karthik
Shanthappa, Arun H
Agarawal, Sandesh
author_sort Ethiraj, Prabhu
collection PubMed
description Introduction There is still a lot of controversy and ambiguity, and no single therapy regimen or strategy for proximal humerus fractures has been proved to be uniformly helpful. According to estimates, only about 20% of proximal humeral fractures require surgery. This study aims at evaluating the functional outcome of treatment of Proximal humerus fractures with PHILOS (Proximal Humerus Inter Locking System) plating using Constant score and assessing the duration for fracture union by follow-up x-rays. Methodology This is a retrospective study on patients admitted to the Department of Orthopaedics attached to a tertiary hospital in Kolar from January 2017 to January 2020. After meeting inclusion and exclusion criteria, 40 patients were included in this study. All the patients underwent PHILOS plating after the pre-anesthetic check-up. The patients were regularly followed up, the functional outcome was assessed using the Constant Murley score, and the fracture union was assessed radiologically by follow-up x-rays. Results The mean age of our forty patients was 46.8 (20-70), with a male: female ratio of 2.3:1. Fractures united at an average of 13.75 weeks. The functional outcome was found to be excellent in 2 patients (5%), good in 22 patients (55%), fair in 7 patients (17.5%), and poor in 9 patients (22.5%). The Constant mean score achieved was 68.75±14.03. The mean time of fracture union was 13.75 weeks. The constant score was compared between variables like age groups, sex, fracture pattern, and mode of injury, but the values were statistically insignificant. Conclusion Even in individuals with osteopenic bones, we achieved excellent to good fracture repair in most cases. The locking plate provides adequate fracture stability and facilitates early shoulder mobilization without hindering fracture union.
format Online
Article
Text
id pubmed-9339088
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-93390882022-08-01 Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures? Ethiraj, Prabhu Venkataraman, Sagar S J, Karthik Shanthappa, Arun H Agarawal, Sandesh Cureus Orthopedics Introduction There is still a lot of controversy and ambiguity, and no single therapy regimen or strategy for proximal humerus fractures has been proved to be uniformly helpful. According to estimates, only about 20% of proximal humeral fractures require surgery. This study aims at evaluating the functional outcome of treatment of Proximal humerus fractures with PHILOS (Proximal Humerus Inter Locking System) plating using Constant score and assessing the duration for fracture union by follow-up x-rays. Methodology This is a retrospective study on patients admitted to the Department of Orthopaedics attached to a tertiary hospital in Kolar from January 2017 to January 2020. After meeting inclusion and exclusion criteria, 40 patients were included in this study. All the patients underwent PHILOS plating after the pre-anesthetic check-up. The patients were regularly followed up, the functional outcome was assessed using the Constant Murley score, and the fracture union was assessed radiologically by follow-up x-rays. Results The mean age of our forty patients was 46.8 (20-70), with a male: female ratio of 2.3:1. Fractures united at an average of 13.75 weeks. The functional outcome was found to be excellent in 2 patients (5%), good in 22 patients (55%), fair in 7 patients (17.5%), and poor in 9 patients (22.5%). The Constant mean score achieved was 68.75±14.03. The mean time of fracture union was 13.75 weeks. The constant score was compared between variables like age groups, sex, fracture pattern, and mode of injury, but the values were statistically insignificant. Conclusion Even in individuals with osteopenic bones, we achieved excellent to good fracture repair in most cases. The locking plate provides adequate fracture stability and facilitates early shoulder mobilization without hindering fracture union. Cureus 2022-06-30 /pmc/articles/PMC9339088/ /pubmed/35919369 http://dx.doi.org/10.7759/cureus.26474 Text en Copyright © 2022, Ethiraj et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Ethiraj, Prabhu
Venkataraman, Sagar
S J, Karthik
Shanthappa, Arun H
Agarawal, Sandesh
Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title_full Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title_fullStr Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title_full_unstemmed Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title_short Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
title_sort does proximal humerus inter locking system (philos) plating provide a good functional outcome in proximal humerus fractures?
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339088/
https://www.ncbi.nlm.nih.gov/pubmed/35919369
http://dx.doi.org/10.7759/cureus.26474
work_keys_str_mv AT ethirajprabhu doesproximalhumerusinterlockingsystemphilosplatingprovideagoodfunctionaloutcomeinproximalhumerusfractures
AT venkataramansagar doesproximalhumerusinterlockingsystemphilosplatingprovideagoodfunctionaloutcomeinproximalhumerusfractures
AT sjkarthik doesproximalhumerusinterlockingsystemphilosplatingprovideagoodfunctionaloutcomeinproximalhumerusfractures
AT shanthappaarunh doesproximalhumerusinterlockingsystemphilosplatingprovideagoodfunctionaloutcomeinproximalhumerusfractures
AT agarawalsandesh doesproximalhumerusinterlockingsystemphilosplatingprovideagoodfunctionaloutcomeinproximalhumerusfractures