Cargando…

Wind of change: Better air for microbial environmental control

BACKGROUND: The COVID19 epidemic highlighted the importance of air in the transmission of pathogens. Air disinfection is one of the key points to reduce the risk of transmission both in the health sector and in public, civil and industrial environments. All bacteria and viruses tested to date can be...

Descripción completa

Detalles Bibliográficos
Autores principales: Messina, G., Amodeo, D., Taddeini, F., De Palma, I., Puccio, A., Cevenini, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Authors. Published by Elsevier Ltd. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339158/
https://www.ncbi.nlm.nih.gov/pubmed/37520926
http://dx.doi.org/10.1016/j.cscee.2022.100240
_version_ 1784760131712450560
author Messina, G.
Amodeo, D.
Taddeini, F.
De Palma, I.
Puccio, A.
Cevenini, G.
author_facet Messina, G.
Amodeo, D.
Taddeini, F.
De Palma, I.
Puccio, A.
Cevenini, G.
author_sort Messina, G.
collection PubMed
description BACKGROUND: The COVID19 epidemic highlighted the importance of air in the transmission of pathogens. Air disinfection is one of the key points to reduce the risk of transmission both in the health sector and in public, civil and industrial environments. All bacteria and viruses tested to date can be inactivated by UV-C rays. Laboratory tested UV-C systems are increasingly popular and proposed as effective technologies for air purification; few studies have evaluated their performance in populated indoor environments. The aim of this investigation was to evaluate the effectiveness of a UV-C disinfection system for air in a real working context. METHODS: This experimental study was conducted between December 2020 and February 2021 in an office of the Department of Molecular and Developmental Medicine of the University of Siena, Italy. A pre-final version air purifier (Cleaning Air T12), capable of treating 210 m(3)/h of air, was first tested for its ability to filter particulates and reduce microbial air contamination in the absence of people. Subsequently, the experiments were conducted in the presence of 3–5 subjects who worked for several hours in an office. During the tests, microbiological samples of air were collected in real time, switching the system on and off periodically. Air samples were collected and incubated on Petri dishes at 36 °C and 22 °C. Statistical analysis was performed with Stata 16 software assuming a significance level of 95%. An interpolating model was identified to describe the dynamics of contamination reduction when the device operates. RESULTS: Preliminary tests showed a significant 62.5% reduction in Colony-Forming Units (CFUs) with 36 °C incubation. Reductions in the particulate component were also observed. In the main test, comparison of CFU data, between the device-on phase (90 min) and the subsequent device-off phase (60 min), showed statistically significant increase (p = 0.001) of environmental contamination passing from a mean of 86.6 (65.8–107.4) to 171.1 (143.9–198.3) CFU/m(3), that is a rise of about 100%. The interpolating model exhibited a good fit of CFU reduction trend with the device on. CONCLUSIONS: The system, which mainly uses UV-C lamps for disinfection, was able to significantly reduce environmental and human contamination in real time. Experimental tests have shown that as soon as the device is switched off, after at least half an hour of operation, the healthiness of the air decreases drastically within 10 minutes, bringing the airborne microbial contamination (induced by the presence of operators in the environment) to levels even higher than 150% of the last value with the device on. Re-engineering strategies for system improvement were also discussed.
format Online
Article
Text
id pubmed-9339158
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Authors. Published by Elsevier Ltd.
record_format MEDLINE/PubMed
spelling pubmed-93391582022-08-01 Wind of change: Better air for microbial environmental control Messina, G. Amodeo, D. Taddeini, F. De Palma, I. Puccio, A. Cevenini, G. Case Studies in Chemical and Environmental Engineering Case Report BACKGROUND: The COVID19 epidemic highlighted the importance of air in the transmission of pathogens. Air disinfection is one of the key points to reduce the risk of transmission both in the health sector and in public, civil and industrial environments. All bacteria and viruses tested to date can be inactivated by UV-C rays. Laboratory tested UV-C systems are increasingly popular and proposed as effective technologies for air purification; few studies have evaluated their performance in populated indoor environments. The aim of this investigation was to evaluate the effectiveness of a UV-C disinfection system for air in a real working context. METHODS: This experimental study was conducted between December 2020 and February 2021 in an office of the Department of Molecular and Developmental Medicine of the University of Siena, Italy. A pre-final version air purifier (Cleaning Air T12), capable of treating 210 m(3)/h of air, was first tested for its ability to filter particulates and reduce microbial air contamination in the absence of people. Subsequently, the experiments were conducted in the presence of 3–5 subjects who worked for several hours in an office. During the tests, microbiological samples of air were collected in real time, switching the system on and off periodically. Air samples were collected and incubated on Petri dishes at 36 °C and 22 °C. Statistical analysis was performed with Stata 16 software assuming a significance level of 95%. An interpolating model was identified to describe the dynamics of contamination reduction when the device operates. RESULTS: Preliminary tests showed a significant 62.5% reduction in Colony-Forming Units (CFUs) with 36 °C incubation. Reductions in the particulate component were also observed. In the main test, comparison of CFU data, between the device-on phase (90 min) and the subsequent device-off phase (60 min), showed statistically significant increase (p = 0.001) of environmental contamination passing from a mean of 86.6 (65.8–107.4) to 171.1 (143.9–198.3) CFU/m(3), that is a rise of about 100%. The interpolating model exhibited a good fit of CFU reduction trend with the device on. CONCLUSIONS: The system, which mainly uses UV-C lamps for disinfection, was able to significantly reduce environmental and human contamination in real time. Experimental tests have shown that as soon as the device is switched off, after at least half an hour of operation, the healthiness of the air decreases drastically within 10 minutes, bringing the airborne microbial contamination (induced by the presence of operators in the environment) to levels even higher than 150% of the last value with the device on. Re-engineering strategies for system improvement were also discussed. The Authors. Published by Elsevier Ltd. 2022-12 2022-07-31 /pmc/articles/PMC9339158/ /pubmed/37520926 http://dx.doi.org/10.1016/j.cscee.2022.100240 Text en © 2022 The Authors Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Case Report
Messina, G.
Amodeo, D.
Taddeini, F.
De Palma, I.
Puccio, A.
Cevenini, G.
Wind of change: Better air for microbial environmental control
title Wind of change: Better air for microbial environmental control
title_full Wind of change: Better air for microbial environmental control
title_fullStr Wind of change: Better air for microbial environmental control
title_full_unstemmed Wind of change: Better air for microbial environmental control
title_short Wind of change: Better air for microbial environmental control
title_sort wind of change: better air for microbial environmental control
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339158/
https://www.ncbi.nlm.nih.gov/pubmed/37520926
http://dx.doi.org/10.1016/j.cscee.2022.100240
work_keys_str_mv AT messinag windofchangebetterairformicrobialenvironmentalcontrol
AT amodeod windofchangebetterairformicrobialenvironmentalcontrol
AT taddeinif windofchangebetterairformicrobialenvironmentalcontrol
AT depalmai windofchangebetterairformicrobialenvironmentalcontrol
AT puccioa windofchangebetterairformicrobialenvironmentalcontrol
AT ceveninig windofchangebetterairformicrobialenvironmentalcontrol