Cargando…

Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)

PURPOSE: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time‐interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND METHODS: A nonlocalized efficiency shimming cost function is...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Xiaoxuan, Schmidt, Simon, Zbýň, Štefan, Haluptzok, Tobey, Moeller, Steen, Metzger, Gregory J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339473/
https://www.ncbi.nlm.nih.gov/pubmed/35692053
http://dx.doi.org/10.1002/mrm.29318
_version_ 1784760187854258176
author He, Xiaoxuan
Schmidt, Simon
Zbýň, Štefan
Haluptzok, Tobey
Moeller, Steen
Metzger, Gregory J.
author_facet He, Xiaoxuan
Schmidt, Simon
Zbýň, Štefan
Haluptzok, Tobey
Moeller, Steen
Metzger, Gregory J.
author_sort He, Xiaoxuan
collection PubMed
description PURPOSE: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time‐interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND METHODS: A nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions. RESULTS: The proposed nonlocalized efficiency RF shimming produced a circularly polarized‐like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV. CONCLUSION: AMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions.
format Online
Article
Text
id pubmed-9339473
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93394732022-10-14 Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE) He, Xiaoxuan Schmidt, Simon Zbýň, Štefan Haluptzok, Tobey Moeller, Steen Metzger, Gregory J. Magn Reson Med Research Articles–Imaging Methodology PURPOSE: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time‐interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND METHODS: A nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions. RESULTS: The proposed nonlocalized efficiency RF shimming produced a circularly polarized‐like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV. CONCLUSION: AMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions. John Wiley and Sons Inc. 2022-06-12 2022-10 /pmc/articles/PMC9339473/ /pubmed/35692053 http://dx.doi.org/10.1002/mrm.29318 Text en © 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles–Imaging Methodology
He, Xiaoxuan
Schmidt, Simon
Zbýň, Štefan
Haluptzok, Tobey
Moeller, Steen
Metzger, Gregory J.
Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title_full Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title_fullStr Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title_full_unstemmed Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title_short Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)
title_sort improved tse imaging at ultrahigh field using nonlocalized efficiency rf shimming and acquisition modes optimized for refocused echoes (amore)
topic Research Articles–Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339473/
https://www.ncbi.nlm.nih.gov/pubmed/35692053
http://dx.doi.org/10.1002/mrm.29318
work_keys_str_mv AT hexiaoxuan improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore
AT schmidtsimon improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore
AT zbynstefan improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore
AT haluptzoktobey improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore
AT moellersteen improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore
AT metzgergregoryj improvedtseimagingatultrahighfieldusingnonlocalizedefficiencyrfshimmingandacquisitionmodesoptimizedforrefocusedechoesamore