Cargando…

Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI

PURPOSE: The gradient‐echo‐train‐based Sub‐millisecond Periodic Event Encoded Dynamic Imaging (get‐SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at deve...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Qingfei, Zhong, Zheng, Sun, Kaibao, Scotti, Alessandro, Zhou, Xiaohong Joe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339512/
https://www.ncbi.nlm.nih.gov/pubmed/35666824
http://dx.doi.org/10.1002/mrm.29313
_version_ 1784760190135959552
author Luo, Qingfei
Zhong, Zheng
Sun, Kaibao
Scotti, Alessandro
Zhou, Xiaohong Joe
author_facet Luo, Qingfei
Zhong, Zheng
Sun, Kaibao
Scotti, Alessandro
Zhou, Xiaohong Joe
author_sort Luo, Qingfei
collection PubMed
description PURPOSE: The gradient‐echo‐train‐based Sub‐millisecond Periodic Event Encoded Dynamic Imaging (get‐SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get‐SPEEDI for reducing the scan time without degrading temporal resolution or image quality. METHODS: The proposed pulse sequence, named k‐t get‐SPEEDI, accelerated get‐SPEEDI acquisition by undersampling the k‐space phase‐encoding lines semi‐randomly. At each time frame, k‐space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time‐series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k‐t get‐SPEEDI, images of human aortic valve opening and closing were acquired with 0.6‐ms temporal resolution and compared with those from conventional get‐SPEEDI. RESULTS: k‐t get‐SPEEDI achieved a 2‐fold scan time reduction over the conventional get‐SPEEDI (from ∼6 to ∼3 min), while achieving comparable SNRs and contrast‐to‐noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR [Formula: see text] 70/38 vs. 73/39 in the k‐t and conventional get‐SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. CONCLUSIONS: The k‐t get‐SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques.
format Online
Article
Text
id pubmed-9339512
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93395122022-10-14 Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI Luo, Qingfei Zhong, Zheng Sun, Kaibao Scotti, Alessandro Zhou, Xiaohong Joe Magn Reson Med Research Articles–Imaging Methodology PURPOSE: The gradient‐echo‐train‐based Sub‐millisecond Periodic Event Encoded Dynamic Imaging (get‐SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get‐SPEEDI for reducing the scan time without degrading temporal resolution or image quality. METHODS: The proposed pulse sequence, named k‐t get‐SPEEDI, accelerated get‐SPEEDI acquisition by undersampling the k‐space phase‐encoding lines semi‐randomly. At each time frame, k‐space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time‐series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k‐t get‐SPEEDI, images of human aortic valve opening and closing were acquired with 0.6‐ms temporal resolution and compared with those from conventional get‐SPEEDI. RESULTS: k‐t get‐SPEEDI achieved a 2‐fold scan time reduction over the conventional get‐SPEEDI (from ∼6 to ∼3 min), while achieving comparable SNRs and contrast‐to‐noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR [Formula: see text] 70/38 vs. 73/39 in the k‐t and conventional get‐SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. CONCLUSIONS: The k‐t get‐SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques. John Wiley and Sons Inc. 2022-06-06 2022-10 /pmc/articles/PMC9339512/ /pubmed/35666824 http://dx.doi.org/10.1002/mrm.29313 Text en © 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles–Imaging Methodology
Luo, Qingfei
Zhong, Zheng
Sun, Kaibao
Scotti, Alessandro
Zhou, Xiaohong Joe
Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title_full Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title_fullStr Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title_full_unstemmed Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title_short Gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐SPEEDI
title_sort gradient‐echo‐train‐based sub‐millisecond periodic event encoded dynamic imaging with random (k, t)‐space undersampling: k‐t get‐speedi
topic Research Articles–Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339512/
https://www.ncbi.nlm.nih.gov/pubmed/35666824
http://dx.doi.org/10.1002/mrm.29313
work_keys_str_mv AT luoqingfei gradientechotrainbasedsubmillisecondperiodiceventencodeddynamicimagingwithrandomktspaceundersamplingktgetspeedi
AT zhongzheng gradientechotrainbasedsubmillisecondperiodiceventencodeddynamicimagingwithrandomktspaceundersamplingktgetspeedi
AT sunkaibao gradientechotrainbasedsubmillisecondperiodiceventencodeddynamicimagingwithrandomktspaceundersamplingktgetspeedi
AT scottialessandro gradientechotrainbasedsubmillisecondperiodiceventencodeddynamicimagingwithrandomktspaceundersamplingktgetspeedi
AT zhouxiaohongjoe gradientechotrainbasedsubmillisecondperiodiceventencodeddynamicimagingwithrandomktspaceundersamplingktgetspeedi