Cargando…

A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy

INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard fram...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Yue, Cai, Pu, Zhang, Huawei, Adilijiang, Aihemaitiniyazi, Peng, Jun, Li, Yun, Che, Shanli, Lan, Fei, Liu, Changqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339900/
https://www.ncbi.nlm.nih.gov/pubmed/35923834
http://dx.doi.org/10.3389/fneur.2022.928070
_version_ 1784760275245727744
author Hu, Yue
Cai, Pu
Zhang, Huawei
Adilijiang, Aihemaitiniyazi
Peng, Jun
Li, Yun
Che, Shanli
Lan, Fei
Liu, Changqing
author_facet Hu, Yue
Cai, Pu
Zhang, Huawei
Adilijiang, Aihemaitiniyazi
Peng, Jun
Li, Yun
Che, Shanli
Lan, Fei
Liu, Changqing
author_sort Hu, Yue
collection PubMed
description INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. METHODS: A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. RESULTS: There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. CONCLUSION: Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery.
format Online
Article
Text
id pubmed-9339900
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-93399002022-08-02 A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy Hu, Yue Cai, Pu Zhang, Huawei Adilijiang, Aihemaitiniyazi Peng, Jun Li, Yun Che, Shanli Lan, Fei Liu, Changqing Front Neurol Neurology INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. METHODS: A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. RESULTS: There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. CONCLUSION: Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery. Frontiers Media S.A. 2022-07-18 /pmc/articles/PMC9339900/ /pubmed/35923834 http://dx.doi.org/10.3389/fneur.2022.928070 Text en Copyright © 2022 Hu, Cai, Zhang, Adilijiang, Peng, Li, Che, Lan and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Hu, Yue
Cai, Pu
Zhang, Huawei
Adilijiang, Aihemaitiniyazi
Peng, Jun
Li, Yun
Che, Shanli
Lan, Fei
Liu, Changqing
A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title_full A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title_fullStr A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title_full_unstemmed A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title_short A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy
title_sort comparation between frame-based and robot-assisted in stereotactic biopsy
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339900/
https://www.ncbi.nlm.nih.gov/pubmed/35923834
http://dx.doi.org/10.3389/fneur.2022.928070
work_keys_str_mv AT huyue acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT caipu acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT zhanghuawei acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT adilijiangaihemaitiniyazi acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT pengjun acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT liyun acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT cheshanli acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT lanfei acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT liuchangqing acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT huyue comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT caipu comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT zhanghuawei comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT adilijiangaihemaitiniyazi comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT pengjun comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT liyun comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT cheshanli comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT lanfei comparationbetweenframebasedandrobotassistedinstereotacticbiopsy
AT liuchangqing comparationbetweenframebasedandrobotassistedinstereotacticbiopsy