INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard fram...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339900/ https://www.ncbi.nlm.nih.gov/pubmed/35923834 http://dx.doi.org/10.3389/fneur.2022.928070 |
_version_ | 1784760275245727744 |
---|---|
author | Hu, Yue Cai, Pu Zhang, Huawei Adilijiang, Aihemaitiniyazi Peng, Jun Li, Yun Che, Shanli Lan, Fei Liu, Changqing |
author_facet | Hu, Yue Cai, Pu Zhang, Huawei Adilijiang, Aihemaitiniyazi Peng, Jun Li, Yun Che, Shanli Lan, Fei Liu, Changqing |
author_sort | Hu, Yue |
collection | PubMed |
description | INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. METHODS: A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. RESULTS: There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. CONCLUSION: Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery. |
format | Online Article Text |
id | pubmed-9339900 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93399002022-08-02 A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy Hu, Yue Cai, Pu Zhang, Huawei Adilijiang, Aihemaitiniyazi Peng, Jun Li, Yun Che, Shanli Lan, Fei Liu, Changqing Front Neurol Neurology INTRODUCTION: Frame-based stereotactic biopsy is well-established to play an essential role in neurosurgery. In recent years, different robotic devices have been introduced in neurosurgery centers. This study aimed to compare the SINO surgical robot-assisted frameless brain biopsy with standard frame-based stereotactic biopsy in terms of efficacy, accuracy and complications. METHODS: A retrospective analysis was performed on 151 consecutive patients who underwent stereotactic biopsy at Chongqing Sanbo Jiangling Hospital between August 2017 and December 2021. All patients were divided into the frame-based group (n = 47) and the SINO surgical robot-assisted group (n = 104). The data collected included clinical characteristics, diagnostic yield, operation times, accuracy, and postoperative complications. RESULTS: There was no significant difference in diagnostic yield between the frame-based group and the SINO surgical robot-assisted group (95.74 vs. 98.08%, p > 0.05). The mean operation time in the SINO surgical robot-assisted group was significantly shorter than in the frame-based group (29.36 ± 13.64 vs. 50.57 ± 41.08 min). The entry point error in the frame-based group was significantly higher than in the robot-assisted group [1.33 ± 0.40 mm (0.47–2.30) vs. 0.92 ± 0.27 mm (0.35–1.65), P < 0.001]. The target point error in the frame-based group was also significantly higher than in the robot-assisted group [1.63 ± 0.41 mm (0.74–2.65) vs. 1.10 ± 0.30 mm (0.69–2.03), P < 0.001]. Finally, there was no significant difference in postoperative complications between the two groups. CONCLUSION: Robot-assisted brain biopsy becomes an increasingly mainstream tool in the neurosurgical procedure. The SINO surgical robot-assisted platform is as efficient, accurate and safe as standard frame-based stereotactic biopsy and provides a reasonable alternative to stereotactic biopsy in neurosurgery. Frontiers Media S.A. 2022-07-18 /pmc/articles/PMC9339900/ /pubmed/35923834 http://dx.doi.org/10.3389/fneur.2022.928070 Text en Copyright © 2022 Hu, Cai, Zhang, Adilijiang, Peng, Li, Che, Lan and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Hu, Yue Cai, Pu Zhang, Huawei Adilijiang, Aihemaitiniyazi Peng, Jun Li, Yun Che, Shanli Lan, Fei Liu, Changqing A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title | A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title_full | A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title_fullStr | A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title_full_unstemmed | A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title_short | A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy |
title_sort | comparation between frame-based and robot-assisted in stereotactic biopsy |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9339900/ https://www.ncbi.nlm.nih.gov/pubmed/35923834 http://dx.doi.org/10.3389/fneur.2022.928070 |
work_keys_str_mv | AT huyue acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT caipu acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT zhanghuawei acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT adilijiangaihemaitiniyazi acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT pengjun acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT liyun acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT cheshanli acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT lanfei acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT liuchangqing acomparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT huyue comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT caipu comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT zhanghuawei comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT adilijiangaihemaitiniyazi comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT pengjun comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT liyun comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT cheshanli comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT lanfei comparationbetweenframebasedandrobotassistedinstereotacticbiopsy AT liuchangqing comparationbetweenframebasedandrobotassistedinstereotacticbiopsy |