Cargando…
Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique()
The development of three-dimensional printers has facilitated the creation of patient-specific hollow vessel models. Preoperative simulations using these types of models have improved our ability to select appropriate devices and embolic materials before performing complex endovascular procedures. T...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9340117/ https://www.ncbi.nlm.nih.gov/pubmed/35923334 http://dx.doi.org/10.1016/j.radcr.2022.07.028 |
_version_ | 1784760328715763712 |
---|---|
author | Morita, Ryo Abo, Daisuke Soyama, Takeshi Imai, Tetsuaki Takahashi, Bunya Yoshino, Yuki Kinota, Naoya Hamaguchi, Hiroyuki Kameda, Takuto Kudo, Kohsuke |
author_facet | Morita, Ryo Abo, Daisuke Soyama, Takeshi Imai, Tetsuaki Takahashi, Bunya Yoshino, Yuki Kinota, Naoya Hamaguchi, Hiroyuki Kameda, Takuto Kudo, Kohsuke |
author_sort | Morita, Ryo |
collection | PubMed |
description | The development of three-dimensional printers has facilitated the creation of patient-specific hollow vessel models. Preoperative simulations using these types of models have improved our ability to select appropriate devices and embolic materials before performing complex endovascular procedures. This report describes 2 cases of high-flow renal arteriovenous fistulas (r-AVFs) that were successfully treated via short-segment embolization using the preloading coil-in-plug (p-CIP) technique. To our knowledge, this is the first report of r-AVF being treated using the p-CIP technique. Our findings demonstrate that preoperative simulation has the potential to improve the safety and reliability of complex vascular embolization procedures. |
format | Online Article Text |
id | pubmed-9340117 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-93401172022-08-02 Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() Morita, Ryo Abo, Daisuke Soyama, Takeshi Imai, Tetsuaki Takahashi, Bunya Yoshino, Yuki Kinota, Naoya Hamaguchi, Hiroyuki Kameda, Takuto Kudo, Kohsuke Radiol Case Rep Case Report The development of three-dimensional printers has facilitated the creation of patient-specific hollow vessel models. Preoperative simulations using these types of models have improved our ability to select appropriate devices and embolic materials before performing complex endovascular procedures. This report describes 2 cases of high-flow renal arteriovenous fistulas (r-AVFs) that were successfully treated via short-segment embolization using the preloading coil-in-plug (p-CIP) technique. To our knowledge, this is the first report of r-AVF being treated using the p-CIP technique. Our findings demonstrate that preoperative simulation has the potential to improve the safety and reliability of complex vascular embolization procedures. Elsevier 2022-07-29 /pmc/articles/PMC9340117/ /pubmed/35923334 http://dx.doi.org/10.1016/j.radcr.2022.07.028 Text en © 2022 The Authors. Published by Elsevier Inc. on behalf of University of Washington. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Morita, Ryo Abo, Daisuke Soyama, Takeshi Imai, Tetsuaki Takahashi, Bunya Yoshino, Yuki Kinota, Naoya Hamaguchi, Hiroyuki Kameda, Takuto Kudo, Kohsuke Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title | Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title_full | Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title_fullStr | Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title_full_unstemmed | Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title_short | Usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
title_sort | usefulness of preoperative simulation with patient-specific hollow vascular models for high-flow renal arteriovenous fistula embolization using a preloading coil-in-plug technique() |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9340117/ https://www.ncbi.nlm.nih.gov/pubmed/35923334 http://dx.doi.org/10.1016/j.radcr.2022.07.028 |
work_keys_str_mv | AT moritaryo usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT abodaisuke usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT soyamatakeshi usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT imaitetsuaki usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT takahashibunya usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT yoshinoyuki usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT kinotanaoya usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT hamaguchihiroyuki usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT kamedatakuto usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique AT kudokohsuke usefulnessofpreoperativesimulationwithpatientspecifichollowvascularmodelsforhighflowrenalarteriovenousfistulaembolizationusingapreloadingcoilinplugtechnique |