Cargando…
Two decades of implantable cardioverter defibrillator implantation and follow-up at a South African referral centre: trends, indications and long-term outcomes in a resource-limited setting
BACKGROUND: More than two-thirds of cardiovascular deaths occur in low- and middle-income countries. Sudden cardiac deaths (SCD) from ventricular arrhythmias are an important cause of cardiovascular deaths. Implantable cardioverter defibrillators (ICD) are an important therapeutic strategy for detec...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9340675/ https://www.ncbi.nlm.nih.gov/pubmed/35937563 http://dx.doi.org/10.1186/s42444-022-00070-2 |
Sumario: | BACKGROUND: More than two-thirds of cardiovascular deaths occur in low- and middle-income countries. Sudden cardiac deaths (SCD) from ventricular arrhythmias are an important cause of cardiovascular deaths. Implantable cardioverter defibrillators (ICD) are an important therapeutic strategy for detecting and terminating ventricular arrhythmias in patients at risk of SCD. The profile of patients treated with ICDs in South Africa is unknown. Further, with changing lines of evidence, the implantation trends are undetermined. The objectives of this study were to determine the profile of ICD recipients and implantation trends in a South African quaternary hospital. METHODS: This was a retrospective review of all patients implanted with ICDs at Groote Schuur Hospital from 01 January 1998 to 31 December 2020. A standardised data collection form was used to collect baseline demographic data, information on clinical presentation and ICD follow-up data for the history of ICD shock therapies. RESULTS: A total of 253 ICDs were implanted; 75% for secondary prevention and 25% for primary prevention. 67.2% of the implanted ICDs were single-chamber ICDs, dual-chamber ICDs were implanted in 12.3% and Cardiac resynchronisation with a defibrillator (CRT-D) in 20.6%. There was an upward trajectory of ICD implantations during the study period. Increasing numbers of dual-chamber devices and CRT-D were implanted over time. ICD recipients had a mean (standard deviation) age of 50 (14) years and were predominantly male (69%). Primary prevention ICD recipients were younger than secondary prevention recipients, with a mean (SD) age of 46 (14) years versus 51 (14) years, p = 0.019. The secondary prevention group presented with ventricular tachycardia in 81%, ventricular fibrillation in 13% and cardiopulmonary resuscitation without documented heart rhythm in 5.3% (10/190). After a median (interquartile range) follow-up of 44 (15; 93) months, there was an overall mortality rate of 16.2%, with no mortality difference between the primary and secondary prevention patient groups. CONCLUSION: There is an increase in the annual number of ICDs implanted at a South African referral centre. ICDs are predominantly implanted for secondary prevention. However, over time the number of devices implanted for primary prevention is steadily increased. During follow-up, there was no mortality difference between the primary prevention and the secondary prevention groups. |
---|