Cargando…

Validation of the Dutch translation of the quality of recovery-15 scale

BACKGROUND: The 15-item Quality of Recovery-15 (QoR-15) scale is strongly recommended as a standard patient-reported outcome measure assessing the quality of recovery after surgery and anesthesia in the postoperative period. This study aimed to validate the Dutch translation of the questionnaire (Qo...

Descripción completa

Detalles Bibliográficos
Autores principales: de Vlieger, Johannes C. N., Luiting, Willem H., Lockyer, Jessica, Meyer, Peter, Fleer, Joke, Sanderman, Robbert, Wietasch, J. K. Götz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9341122/
https://www.ncbi.nlm.nih.gov/pubmed/35915438
http://dx.doi.org/10.1186/s12871-022-01784-5
Descripción
Sumario:BACKGROUND: The 15-item Quality of Recovery-15 (QoR-15) scale is strongly recommended as a standard patient-reported outcome measure assessing the quality of recovery after surgery and anesthesia in the postoperative period. This study aimed to validate the Dutch translation of the questionnaire (QoR-15NL). MATERIALS AND METHODS: An observational, prospective, single-centre cohort study was conducted. Patients who underwent surgery under general anesthesia completed the QoR-15NL (preoperatively (t1) and twice postoperatively (t2 and t3)) and a visual analogue scale (VAS) for general recovery at t2. A psychometric evaluation was performed to assess the QoR-15NL’s validity, reliability, responsiveness, reproducibility and feasibility. RESULTS: Two hundred and eleven patients agreed to participate (recruitment rate 94%), and 165 patients were included (completion rate 78%). The QoR-15NL score correlated with the VAS for general recovery (rs = 0.59). Construct validity was further demonstrated by confirmation of expected negative associations between the QoR-15NL and duration of surgery (rs = -0.25), duration of Post Anesthesia Care Unit stay (rs = -0.31), and duration of hospital stay (rs = -0.27). The QoR-15NL score decreased significantly according to the extent of surgery. Cronbach’s alpha was 0.87, split-half reliability was 0.8, and the test–retest intra-class coefficient was 0.93. No significant floor- or ceiling effect was observed. CONCLUSION: The QoR-15NL scale is a valid, easy-to-use, and reliable outcome assessment tool with high responsiveness for patient-reported quality of recovery after surgery and general anesthesia in the Dutch-speaking population. The QoR-15NL’s measurement properties are comparable to the original questionnaire and other translated versions. TRIAL REGISTRATION: not applicable. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01784-5.