Cargando…

Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model

Tissue-engineered skin constructs have been under development since the 1980s as a replacement for human skin tissues and animal models for therapeutics and cosmetic testing. These have evolved from simple single-cell assays to increasingly complex models with integrated dermal equivalents and multi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jones, Christian F. E., Di Cio, Stefania, Connelly, John T., Gautrot, Julien E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9343775/
https://www.ncbi.nlm.nih.gov/pubmed/35928950
http://dx.doi.org/10.3389/fbioe.2022.915702
_version_ 1784761065196748800
author Jones, Christian F. E.
Di Cio, Stefania
Connelly, John T.
Gautrot, Julien E.
author_facet Jones, Christian F. E.
Di Cio, Stefania
Connelly, John T.
Gautrot, Julien E.
author_sort Jones, Christian F. E.
collection PubMed
description Tissue-engineered skin constructs have been under development since the 1980s as a replacement for human skin tissues and animal models for therapeutics and cosmetic testing. These have evolved from simple single-cell assays to increasingly complex models with integrated dermal equivalents and multiple cell types including a dermis, epidermis, and vasculature. The development of micro-engineered platforms and biomaterials has enabled scientists to better recreate and capture the tissue microenvironment in vitro, including the vascularization of tissue models and their integration into microfluidic chips. However, to date, microvascularized human skin equivalents in a microfluidic context have not been reported. Here, we present the design of a novel skin-on-a-chip model integrating human-derived primary and immortalized cells in a full-thickness skin equivalent. The model is housed in a microfluidic device, in which a microvasculature was previously established. We characterize the impact of our chip design on the quality of the microvascular networks formed and evidence that this enables the formation of more homogenous networks. We developed a methodology to harvest tissues from embedded chips, after 14 days of culture, and characterize the impact of culture conditions and vascularization (including with pericyte co-cultures) on the stratification of the epidermis in the resulting skin equivalents. Our results indicate that vascularization enhances stratification and differentiation (thickness, architecture, and expression of terminal differentiation markers such as involucrin and transglutaminase 1), allowing the formation of more mature skin equivalents in microfluidic chips. The skin-on-a-chip tissue equivalents developed, because of their realistic microvasculature, may find applications for testing efficacy and safety of therapeutics delivered systemically, in a human context.
format Online
Article
Text
id pubmed-9343775
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-93437752022-08-03 Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model Jones, Christian F. E. Di Cio, Stefania Connelly, John T. Gautrot, Julien E. Front Bioeng Biotechnol Bioengineering and Biotechnology Tissue-engineered skin constructs have been under development since the 1980s as a replacement for human skin tissues and animal models for therapeutics and cosmetic testing. These have evolved from simple single-cell assays to increasingly complex models with integrated dermal equivalents and multiple cell types including a dermis, epidermis, and vasculature. The development of micro-engineered platforms and biomaterials has enabled scientists to better recreate and capture the tissue microenvironment in vitro, including the vascularization of tissue models and their integration into microfluidic chips. However, to date, microvascularized human skin equivalents in a microfluidic context have not been reported. Here, we present the design of a novel skin-on-a-chip model integrating human-derived primary and immortalized cells in a full-thickness skin equivalent. The model is housed in a microfluidic device, in which a microvasculature was previously established. We characterize the impact of our chip design on the quality of the microvascular networks formed and evidence that this enables the formation of more homogenous networks. We developed a methodology to harvest tissues from embedded chips, after 14 days of culture, and characterize the impact of culture conditions and vascularization (including with pericyte co-cultures) on the stratification of the epidermis in the resulting skin equivalents. Our results indicate that vascularization enhances stratification and differentiation (thickness, architecture, and expression of terminal differentiation markers such as involucrin and transglutaminase 1), allowing the formation of more mature skin equivalents in microfluidic chips. The skin-on-a-chip tissue equivalents developed, because of their realistic microvasculature, may find applications for testing efficacy and safety of therapeutics delivered systemically, in a human context. Frontiers Media S.A. 2022-07-19 /pmc/articles/PMC9343775/ /pubmed/35928950 http://dx.doi.org/10.3389/fbioe.2022.915702 Text en Copyright © 2022 Jones, Di Cio, Connelly and Gautrot. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Jones, Christian F. E.
Di Cio, Stefania
Connelly, John T.
Gautrot, Julien E.
Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title_full Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title_fullStr Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title_full_unstemmed Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title_short Design of an Integrated Microvascularized Human Skin-on-a-Chip Tissue Equivalent Model
title_sort design of an integrated microvascularized human skin-on-a-chip tissue equivalent model
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9343775/
https://www.ncbi.nlm.nih.gov/pubmed/35928950
http://dx.doi.org/10.3389/fbioe.2022.915702
work_keys_str_mv AT joneschristianfe designofanintegratedmicrovascularizedhumanskinonachiptissueequivalentmodel
AT diciostefania designofanintegratedmicrovascularizedhumanskinonachiptissueequivalentmodel
AT connellyjohnt designofanintegratedmicrovascularizedhumanskinonachiptissueequivalentmodel
AT gautrotjuliene designofanintegratedmicrovascularizedhumanskinonachiptissueequivalentmodel