Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis

PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Yong-Cheol, Kim, Chul-Ho, Kim, Yong Chan, Song, Hyung Keun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344276/
https://www.ncbi.nlm.nih.gov/pubmed/35914756
http://dx.doi.org/10.3349/ymj.2022.63.8.744
_version_ 1784761185766211584
author Yoon, Yong-Cheol
Kim, Chul-Ho
Kim, Yong Chan
Song, Hyung Keun
author_facet Yoon, Yong-Cheol
Kim, Chul-Ho
Kim, Yong Chan
Song, Hyung Keun
author_sort Yoon, Yong-Cheol
collection PubMed
description PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN to determine the appropriate fixation method for BFNF. MATERIALS AND METHODS: We systematically searched MEDLINE, Embase, and the Cochrane Library for studies published up to January 9, 2021 that compared the treatment outcomes between CMN and DHS in BFNF. The primary outcomes of the present meta-analysis were fracture union time, postoperative cut-out rate, and reoperation rate. RESULTS: We included seven studies involving 353 cases of BFNF in our review. Of these, 206 patients were treated using CMN, and DHS were utilized in 147 patients. In a pooled analysis, the DHS group required a longer time to achieve fracture union compared to the CMN group [mean difference (MD): -0.41; 95% confidence interval (CI): -0.70, -0.12; p=0.006; I(2)=0%]. However, the cut-out and reoperation rates exhibited no statistically significant differences between the DHS and CMN groups [cut-out odds ratio (OR): 0.54; 95% CI: 0.10, 2.82; p=0.47; I(2)=24%, reoperation rate OR: 0.65; 95% CI: 0.15, 2.86; p=0.57; I(2)=19%, respectively]. CONCLUSION: Stable fixation using DHS and CMN does not show a significant clinical or radiographical difference in BFNF, and the implant can be selected based on the surgeon’s preference.
format Online
Article
Text
id pubmed-9344276
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-93442762022-08-03 Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis Yoon, Yong-Cheol Kim, Chul-Ho Kim, Yong Chan Song, Hyung Keun Yonsei Med J Original Article PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN to determine the appropriate fixation method for BFNF. MATERIALS AND METHODS: We systematically searched MEDLINE, Embase, and the Cochrane Library for studies published up to January 9, 2021 that compared the treatment outcomes between CMN and DHS in BFNF. The primary outcomes of the present meta-analysis were fracture union time, postoperative cut-out rate, and reoperation rate. RESULTS: We included seven studies involving 353 cases of BFNF in our review. Of these, 206 patients were treated using CMN, and DHS were utilized in 147 patients. In a pooled analysis, the DHS group required a longer time to achieve fracture union compared to the CMN group [mean difference (MD): -0.41; 95% confidence interval (CI): -0.70, -0.12; p=0.006; I(2)=0%]. However, the cut-out and reoperation rates exhibited no statistically significant differences between the DHS and CMN groups [cut-out odds ratio (OR): 0.54; 95% CI: 0.10, 2.82; p=0.47; I(2)=24%, reoperation rate OR: 0.65; 95% CI: 0.15, 2.86; p=0.57; I(2)=19%, respectively]. CONCLUSION: Stable fixation using DHS and CMN does not show a significant clinical or radiographical difference in BFNF, and the implant can be selected based on the surgeon’s preference. Yonsei University College of Medicine 2022-08 2022-07-19 /pmc/articles/PMC9344276/ /pubmed/35914756 http://dx.doi.org/10.3349/ymj.2022.63.8.744 Text en © Copyright: Yonsei University College of Medicine 2022 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yoon, Yong-Cheol
Kim, Chul-Ho
Kim, Yong Chan
Song, Hyung Keun
Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title_full Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title_fullStr Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title_full_unstemmed Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title_short Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
title_sort cephalomedullary nailing versus dynamic hip screw fixation in basicervical femoral neck fracture: a systematic review and meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344276/
https://www.ncbi.nlm.nih.gov/pubmed/35914756
http://dx.doi.org/10.3349/ymj.2022.63.8.744
work_keys_str_mv AT yoonyongcheol cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis
AT kimchulho cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis
AT kimyongchan cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis
AT songhyungkeun cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis