Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis
PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344276/ https://www.ncbi.nlm.nih.gov/pubmed/35914756 http://dx.doi.org/10.3349/ymj.2022.63.8.744 |
_version_ | 1784761185766211584 |
---|---|
author | Yoon, Yong-Cheol Kim, Chul-Ho Kim, Yong Chan Song, Hyung Keun |
author_facet | Yoon, Yong-Cheol Kim, Chul-Ho Kim, Yong Chan Song, Hyung Keun |
author_sort | Yoon, Yong-Cheol |
collection | PubMed |
description | PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN to determine the appropriate fixation method for BFNF. MATERIALS AND METHODS: We systematically searched MEDLINE, Embase, and the Cochrane Library for studies published up to January 9, 2021 that compared the treatment outcomes between CMN and DHS in BFNF. The primary outcomes of the present meta-analysis were fracture union time, postoperative cut-out rate, and reoperation rate. RESULTS: We included seven studies involving 353 cases of BFNF in our review. Of these, 206 patients were treated using CMN, and DHS were utilized in 147 patients. In a pooled analysis, the DHS group required a longer time to achieve fracture union compared to the CMN group [mean difference (MD): -0.41; 95% confidence interval (CI): -0.70, -0.12; p=0.006; I(2)=0%]. However, the cut-out and reoperation rates exhibited no statistically significant differences between the DHS and CMN groups [cut-out odds ratio (OR): 0.54; 95% CI: 0.10, 2.82; p=0.47; I(2)=24%, reoperation rate OR: 0.65; 95% CI: 0.15, 2.86; p=0.57; I(2)=19%, respectively]. CONCLUSION: Stable fixation using DHS and CMN does not show a significant clinical or radiographical difference in BFNF, and the implant can be selected based on the surgeon’s preference. |
format | Online Article Text |
id | pubmed-9344276 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-93442762022-08-03 Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis Yoon, Yong-Cheol Kim, Chul-Ho Kim, Yong Chan Song, Hyung Keun Yonsei Med J Original Article PURPOSE: Although many studies have reported the use of dynamic hip screws (DHS) and cephalomedullary nailing (CMN) for basicervical femoral neck fracture (BFNF), no clear treatment protocols have been recommended. The present study aimed to compare the surgical outcomes associated with DHS and CMN to determine the appropriate fixation method for BFNF. MATERIALS AND METHODS: We systematically searched MEDLINE, Embase, and the Cochrane Library for studies published up to January 9, 2021 that compared the treatment outcomes between CMN and DHS in BFNF. The primary outcomes of the present meta-analysis were fracture union time, postoperative cut-out rate, and reoperation rate. RESULTS: We included seven studies involving 353 cases of BFNF in our review. Of these, 206 patients were treated using CMN, and DHS were utilized in 147 patients. In a pooled analysis, the DHS group required a longer time to achieve fracture union compared to the CMN group [mean difference (MD): -0.41; 95% confidence interval (CI): -0.70, -0.12; p=0.006; I(2)=0%]. However, the cut-out and reoperation rates exhibited no statistically significant differences between the DHS and CMN groups [cut-out odds ratio (OR): 0.54; 95% CI: 0.10, 2.82; p=0.47; I(2)=24%, reoperation rate OR: 0.65; 95% CI: 0.15, 2.86; p=0.57; I(2)=19%, respectively]. CONCLUSION: Stable fixation using DHS and CMN does not show a significant clinical or radiographical difference in BFNF, and the implant can be selected based on the surgeon’s preference. Yonsei University College of Medicine 2022-08 2022-07-19 /pmc/articles/PMC9344276/ /pubmed/35914756 http://dx.doi.org/10.3349/ymj.2022.63.8.744 Text en © Copyright: Yonsei University College of Medicine 2022 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Yoon, Yong-Cheol Kim, Chul-Ho Kim, Yong Chan Song, Hyung Keun Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title | Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title_full | Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title_fullStr | Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title_short | Cephalomedullary Nailing versus Dynamic Hip Screw Fixation in Basicervical Femoral Neck Fracture: A Systematic Review and Meta-Analysis |
title_sort | cephalomedullary nailing versus dynamic hip screw fixation in basicervical femoral neck fracture: a systematic review and meta-analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344276/ https://www.ncbi.nlm.nih.gov/pubmed/35914756 http://dx.doi.org/10.3349/ymj.2022.63.8.744 |
work_keys_str_mv | AT yoonyongcheol cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis AT kimchulho cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis AT kimyongchan cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis AT songhyungkeun cephalomedullarynailingversusdynamichipscrewfixationinbasicervicalfemoralneckfractureasystematicreviewandmetaanalysis |