Cargando…

A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes

INTRODUCTION: Due to limitations in currently used methodologies, the widely acknowledged approach for quantifying M-protein (MP) is not available. If employed as a source of quantitative data, the immunosubtraction electropherogram (IS-EPG), a qualitative analysis of MP, has the potential to overco...

Descripción completa

Detalles Bibliográficos
Autores principales: Šegulja, Dragana, Matišić, Danica, Barišić, Karmela, Rogić, Dunja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344871/
https://www.ncbi.nlm.nih.gov/pubmed/35966255
http://dx.doi.org/10.11613/BM.2022.030703
_version_ 1784761309556899840
author Šegulja, Dragana
Matišić, Danica
Barišić, Karmela
Rogić, Dunja
author_facet Šegulja, Dragana
Matišić, Danica
Barišić, Karmela
Rogić, Dunja
author_sort Šegulja, Dragana
collection PubMed
description INTRODUCTION: Due to limitations in currently used methodologies, the widely acknowledged approach for quantifying M-protein (MP) is not available. If employed as a source of quantitative data, the immunosubtraction electropherogram (IS-EPG), a qualitative analysis of MP, has the potential to overcome known analytical issues. The aim of this study is to explore measured and derived variables obtained from immunosubtraction electropherogram as a tool for quantifying MP and to compare the derived results to currently available methods. MATERIALS AND METHODS: Measurands were amplitudes of MP and albumin fractions. Assessed derived variables included also immunoglobulin (Ig) G, IgA, IgM and total protein data. Capillary electrophoresis was used for determination of MP (in % of total protein concentration, or concentration of MP in g/L) by perpendicular drop and tangent skimming method. RESULTS: Passing-Bablok analysis showed the most comparable results in D1Ig and D1nIg variables, and the largest discrepancies in AD1nIg and AD2nIg variables. The background presence had greater impact on D1nIg comparison results than did on D1Ig results. The contribution of albumin fraction data did not improve the comparability of the results. The coefficients of variation of derived variables were lower (maximum 3.1%) than those obtained by densitometric measurements, regardless of MP concentration, polyclonal background, or migration pattern (2.3-37.7%). CONCLUSION: The amplitude of MP spike in IS-EPG is an valuable measurand to compute derived variables for quantifying MP. The most comparable results were achieved with the D1Ig variable. Patients with monoclonal gammopathy can benefit from increased precision employing an objective and background independent measurand, especially during longitudinal follow-up.
format Online
Article
Text
id pubmed-9344871
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-93448712022-08-11 A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes Šegulja, Dragana Matišić, Danica Barišić, Karmela Rogić, Dunja Biochem Med (Zagreb) Original Articles INTRODUCTION: Due to limitations in currently used methodologies, the widely acknowledged approach for quantifying M-protein (MP) is not available. If employed as a source of quantitative data, the immunosubtraction electropherogram (IS-EPG), a qualitative analysis of MP, has the potential to overcome known analytical issues. The aim of this study is to explore measured and derived variables obtained from immunosubtraction electropherogram as a tool for quantifying MP and to compare the derived results to currently available methods. MATERIALS AND METHODS: Measurands were amplitudes of MP and albumin fractions. Assessed derived variables included also immunoglobulin (Ig) G, IgA, IgM and total protein data. Capillary electrophoresis was used for determination of MP (in % of total protein concentration, or concentration of MP in g/L) by perpendicular drop and tangent skimming method. RESULTS: Passing-Bablok analysis showed the most comparable results in D1Ig and D1nIg variables, and the largest discrepancies in AD1nIg and AD2nIg variables. The background presence had greater impact on D1nIg comparison results than did on D1Ig results. The contribution of albumin fraction data did not improve the comparability of the results. The coefficients of variation of derived variables were lower (maximum 3.1%) than those obtained by densitometric measurements, regardless of MP concentration, polyclonal background, or migration pattern (2.3-37.7%). CONCLUSION: The amplitude of MP spike in IS-EPG is an valuable measurand to compute derived variables for quantifying MP. The most comparable results were achieved with the D1Ig variable. Patients with monoclonal gammopathy can benefit from increased precision employing an objective and background independent measurand, especially during longitudinal follow-up. Croatian Society of Medical Biochemistry and Laboratory Medicine 2022-08-05 2022-10-01 /pmc/articles/PMC9344871/ /pubmed/35966255 http://dx.doi.org/10.11613/BM.2022.030703 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Šegulja, Dragana
Matišić, Danica
Barišić, Karmela
Rogić, Dunja
A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title_full A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title_fullStr A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title_full_unstemmed A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title_short A novel approach for more precise quantification of M-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
title_sort novel approach for more precise quantification of m-protein using variables derived from immunosubtraction electropherogram and associated biochemistry analytes
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344871/
https://www.ncbi.nlm.nih.gov/pubmed/35966255
http://dx.doi.org/10.11613/BM.2022.030703
work_keys_str_mv AT seguljadragana anovelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT matisicdanica anovelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT barisickarmela anovelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT rogicdunja anovelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT seguljadragana novelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT matisicdanica novelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT barisickarmela novelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes
AT rogicdunja novelapproachformoreprecisequantificationofmproteinusingvariablesderivedfromimmunosubtractionelectropherogramandassociatedbiochemistryanalytes