Cargando…

Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications

INTRODUCTION: The aim of the study was to determine the current state of laboratory’s extra-analytical phase performance by calculating preanalytical and postanalytical phase quality indicators (QIs) and sigma values and to compare obtained data according to desired quality specifications and sigma...

Descripción completa

Detalles Bibliográficos
Autores principales: Zorbozan, Nergiz, Zorbozan, Orçun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344872/
https://www.ncbi.nlm.nih.gov/pubmed/35966260
http://dx.doi.org/10.11613/BM.2022.030701
_version_ 1784761309805412352
author Zorbozan, Nergiz
Zorbozan, Orçun
author_facet Zorbozan, Nergiz
Zorbozan, Orçun
author_sort Zorbozan, Nergiz
collection PubMed
description INTRODUCTION: The aim of the study was to determine the current state of laboratory’s extra-analytical phase performance by calculating preanalytical and postanalytical phase quality indicators (QIs) and sigma values and to compare obtained data according to desired quality specifications and sigma values reported by The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group – Laboratory errors and Patient Safety. MATERIALS AND METHODS: Preanalytical and postanalytical phase data were obtained through laboratory information system. Rejected samples in preanalytical phase were grouped according to reasons for rejection and frequencies were calculated both monthly and for 2019. Sigma values were calculated according to “short term sigma” table. RESULTS: The number of rejected samples in laboratory was 643 out of 191,831 in 2019. Total preanalytical phase rejection frequency was 0.22%. According to the reasons for rejection, QIs and sigma values were: “Samples with excessive transportation time”: 0.0036 and 5.47; “Samples collected in wrong container” 0.02 and 5.11. In December, QIs and sigma values were: “Samples with excessive transportation time”: 0.01 and 5.34; “Samples collected in wrong container”: 0.03 and 4.98. The postanalytical QIs and sigma values were: “Reports delivered outside the specified time”: 0.34 and 4.21; “Turn around time of potassium”: 56 minute and 3.84, respectively. There were no errors in “Critical values of inpatients and outpatients notified after a consensually agreed time”. CONCLUSIONS: Extra-analytical phase was evaluated by comparing it with the latest quality specifications and sigma values which will contribute to improving the quality of laboratory medicine.
format Online
Article
Text
id pubmed-9344872
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-93448722022-08-11 Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications Zorbozan, Nergiz Zorbozan, Orçun Biochem Med (Zagreb) Original Articles INTRODUCTION: The aim of the study was to determine the current state of laboratory’s extra-analytical phase performance by calculating preanalytical and postanalytical phase quality indicators (QIs) and sigma values and to compare obtained data according to desired quality specifications and sigma values reported by The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group – Laboratory errors and Patient Safety. MATERIALS AND METHODS: Preanalytical and postanalytical phase data were obtained through laboratory information system. Rejected samples in preanalytical phase were grouped according to reasons for rejection and frequencies were calculated both monthly and for 2019. Sigma values were calculated according to “short term sigma” table. RESULTS: The number of rejected samples in laboratory was 643 out of 191,831 in 2019. Total preanalytical phase rejection frequency was 0.22%. According to the reasons for rejection, QIs and sigma values were: “Samples with excessive transportation time”: 0.0036 and 5.47; “Samples collected in wrong container” 0.02 and 5.11. In December, QIs and sigma values were: “Samples with excessive transportation time”: 0.01 and 5.34; “Samples collected in wrong container”: 0.03 and 4.98. The postanalytical QIs and sigma values were: “Reports delivered outside the specified time”: 0.34 and 4.21; “Turn around time of potassium”: 56 minute and 3.84, respectively. There were no errors in “Critical values of inpatients and outpatients notified after a consensually agreed time”. CONCLUSIONS: Extra-analytical phase was evaluated by comparing it with the latest quality specifications and sigma values which will contribute to improving the quality of laboratory medicine. Croatian Society of Medical Biochemistry and Laboratory Medicine 2022-08-05 2022-10-01 /pmc/articles/PMC9344872/ /pubmed/35966260 http://dx.doi.org/10.11613/BM.2022.030701 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Zorbozan, Nergiz
Zorbozan, Orçun
Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title_full Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title_fullStr Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title_full_unstemmed Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title_short Evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to IFCC laboratory errors and patient safety specifications
title_sort evaluation of preanalytical and postanalytical phases in clinical biochemistry laboratory according to ifcc laboratory errors and patient safety specifications
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344872/
https://www.ncbi.nlm.nih.gov/pubmed/35966260
http://dx.doi.org/10.11613/BM.2022.030701
work_keys_str_mv AT zorbozannergiz evaluationofpreanalyticalandpostanalyticalphasesinclinicalbiochemistrylaboratoryaccordingtoifcclaboratoryerrorsandpatientsafetyspecifications
AT zorbozanorcun evaluationofpreanalyticalandpostanalyticalphasesinclinicalbiochemistrylaboratoryaccordingtoifcclaboratoryerrorsandpatientsafetyspecifications