Cargando…
Ventilation through a straw
Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The followin...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Anesthesiologists
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346197/ https://www.ncbi.nlm.nih.gov/pubmed/35918856 http://dx.doi.org/10.17085/apm.22163 |
_version_ | 1784761595877916672 |
---|---|
author | Kim, Hye Jin Kim, Hyun Joo Park, Wyun Kon |
author_facet | Kim, Hye Jin Kim, Hyun Joo Park, Wyun Kon |
author_sort | Kim, Hye Jin |
collection | PubMed |
description | Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The following methods or devices has been used under cricothyrotomy using an intravenous cannula: 1) Ambu (bag valve mask) bagging, 2) Ventrain(®), 3) Rapid-O2 oxygen insufflation device (Rapid-O2), and 4) jet ventilation using a dual lumen catheter. During Ambu bagging, extraordinarily high insufflation pressure is required to force oxygen through the cannula. When using a 12-G cannula, long and slow positive-pressure ventilations (10–12 breaths/min) are required, which makes it extremely difficult to compress the bag. Therefore, a 10-G or larger is recommended. Ventrain(®) is an expiratory assist device capable of forcibly expelling insufflated oxygen through a transtracheal cannula. It is recommended to adjust the inspiratory and expiratory times while observing the chest wall movements. Rapid-O2 is a rescue oxygenation device with adequate ventilation of less importance; therefore, the resulting hypercarbia is inevitable. A 14-G cannula is used. Lastly, jet ventilation using a dual-lumen catheter with a 16-G inflow lumen and 10-G outflow lumen was used to obtain both oxygenation and ventilation. However, the addition of the outer diameters of 16-G and 10-G results in an outer diameter of 5.1 mm, which is too large to puncture the cricothyroid membrane. In conclusion, Ventrain(®) is considered the most ideal device for use among the devices developed to date. |
format | Online Article Text |
id | pubmed-9346197 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-93461972022-08-04 Ventilation through a straw Kim, Hye Jin Kim, Hyun Joo Park, Wyun Kon Anesth Pain Med (Seoul) Review Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The following methods or devices has been used under cricothyrotomy using an intravenous cannula: 1) Ambu (bag valve mask) bagging, 2) Ventrain(®), 3) Rapid-O2 oxygen insufflation device (Rapid-O2), and 4) jet ventilation using a dual lumen catheter. During Ambu bagging, extraordinarily high insufflation pressure is required to force oxygen through the cannula. When using a 12-G cannula, long and slow positive-pressure ventilations (10–12 breaths/min) are required, which makes it extremely difficult to compress the bag. Therefore, a 10-G or larger is recommended. Ventrain(®) is an expiratory assist device capable of forcibly expelling insufflated oxygen through a transtracheal cannula. It is recommended to adjust the inspiratory and expiratory times while observing the chest wall movements. Rapid-O2 is a rescue oxygenation device with adequate ventilation of less importance; therefore, the resulting hypercarbia is inevitable. A 14-G cannula is used. Lastly, jet ventilation using a dual-lumen catheter with a 16-G inflow lumen and 10-G outflow lumen was used to obtain both oxygenation and ventilation. However, the addition of the outer diameters of 16-G and 10-G results in an outer diameter of 5.1 mm, which is too large to puncture the cricothyroid membrane. In conclusion, Ventrain(®) is considered the most ideal device for use among the devices developed to date. Korean Society of Anesthesiologists 2022-07-31 2022-07-07 /pmc/articles/PMC9346197/ /pubmed/35918856 http://dx.doi.org/10.17085/apm.22163 Text en Copyright © the Korean Society of Anesthesiologists, 2022 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Kim, Hye Jin Kim, Hyun Joo Park, Wyun Kon Ventilation through a straw |
title | Ventilation through a straw |
title_full | Ventilation through a straw |
title_fullStr | Ventilation through a straw |
title_full_unstemmed | Ventilation through a straw |
title_short | Ventilation through a straw |
title_sort | ventilation through a straw |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346197/ https://www.ncbi.nlm.nih.gov/pubmed/35918856 http://dx.doi.org/10.17085/apm.22163 |
work_keys_str_mv | AT kimhyejin ventilationthroughastraw AT kimhyunjoo ventilationthroughastraw AT parkwyunkon ventilationthroughastraw |