Cargando…

Ventilation through a straw

Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The followin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hye Jin, Kim, Hyun Joo, Park, Wyun Kon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Anesthesiologists 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346197/
https://www.ncbi.nlm.nih.gov/pubmed/35918856
http://dx.doi.org/10.17085/apm.22163
_version_ 1784761595877916672
author Kim, Hye Jin
Kim, Hyun Joo
Park, Wyun Kon
author_facet Kim, Hye Jin
Kim, Hyun Joo
Park, Wyun Kon
author_sort Kim, Hye Jin
collection PubMed
description Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The following methods or devices has been used under cricothyrotomy using an intravenous cannula: 1) Ambu (bag valve mask) bagging, 2) Ventrain(®), 3) Rapid-O2 oxygen insufflation device (Rapid-O2), and 4) jet ventilation using a dual lumen catheter. During Ambu bagging, extraordinarily high insufflation pressure is required to force oxygen through the cannula. When using a 12-G cannula, long and slow positive-pressure ventilations (10–12 breaths/min) are required, which makes it extremely difficult to compress the bag. Therefore, a 10-G or larger is recommended. Ventrain(®) is an expiratory assist device capable of forcibly expelling insufflated oxygen through a transtracheal cannula. It is recommended to adjust the inspiratory and expiratory times while observing the chest wall movements. Rapid-O2 is a rescue oxygenation device with adequate ventilation of less importance; therefore, the resulting hypercarbia is inevitable. A 14-G cannula is used. Lastly, jet ventilation using a dual-lumen catheter with a 16-G inflow lumen and 10-G outflow lumen was used to obtain both oxygenation and ventilation. However, the addition of the outer diameters of 16-G and 10-G results in an outer diameter of 5.1 mm, which is too large to puncture the cricothyroid membrane. In conclusion, Ventrain(®) is considered the most ideal device for use among the devices developed to date.
format Online
Article
Text
id pubmed-9346197
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-93461972022-08-04 Ventilation through a straw Kim, Hye Jin Kim, Hyun Joo Park, Wyun Kon Anesth Pain Med (Seoul) Review Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The following methods or devices has been used under cricothyrotomy using an intravenous cannula: 1) Ambu (bag valve mask) bagging, 2) Ventrain(®), 3) Rapid-O2 oxygen insufflation device (Rapid-O2), and 4) jet ventilation using a dual lumen catheter. During Ambu bagging, extraordinarily high insufflation pressure is required to force oxygen through the cannula. When using a 12-G cannula, long and slow positive-pressure ventilations (10–12 breaths/min) are required, which makes it extremely difficult to compress the bag. Therefore, a 10-G or larger is recommended. Ventrain(®) is an expiratory assist device capable of forcibly expelling insufflated oxygen through a transtracheal cannula. It is recommended to adjust the inspiratory and expiratory times while observing the chest wall movements. Rapid-O2 is a rescue oxygenation device with adequate ventilation of less importance; therefore, the resulting hypercarbia is inevitable. A 14-G cannula is used. Lastly, jet ventilation using a dual-lumen catheter with a 16-G inflow lumen and 10-G outflow lumen was used to obtain both oxygenation and ventilation. However, the addition of the outer diameters of 16-G and 10-G results in an outer diameter of 5.1 mm, which is too large to puncture the cricothyroid membrane. In conclusion, Ventrain(®) is considered the most ideal device for use among the devices developed to date. Korean Society of Anesthesiologists 2022-07-31 2022-07-07 /pmc/articles/PMC9346197/ /pubmed/35918856 http://dx.doi.org/10.17085/apm.22163 Text en Copyright © the Korean Society of Anesthesiologists, 2022 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review
Kim, Hye Jin
Kim, Hyun Joo
Park, Wyun Kon
Ventilation through a straw
title Ventilation through a straw
title_full Ventilation through a straw
title_fullStr Ventilation through a straw
title_full_unstemmed Ventilation through a straw
title_short Ventilation through a straw
title_sort ventilation through a straw
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346197/
https://www.ncbi.nlm.nih.gov/pubmed/35918856
http://dx.doi.org/10.17085/apm.22163
work_keys_str_mv AT kimhyejin ventilationthroughastraw
AT kimhyunjoo ventilationthroughastraw
AT parkwyunkon ventilationthroughastraw