Cargando…

Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration

This study explores the effects of aging (thermal cycling and cyclic loading–TC/CL) and different light-curing unit (LCU) types on the volume characteristics and internal porosity of a bulk-fill resin-based composite restoration. Occlusal cavities (4 × 4 × 3 mm) were prepared on extracted human mola...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Zain, Afnan O., Alboloshi, Elaf A., Amir, Walaa A., Alghilan, Maryam A., Münchow, Eliseu A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346940/
https://www.ncbi.nlm.nih.gov/pubmed/35935721
http://dx.doi.org/10.1016/j.sdentj.2022.01.004
_version_ 1784761757566238720
author Al-Zain, Afnan O.
Alboloshi, Elaf A.
Amir, Walaa A.
Alghilan, Maryam A.
Münchow, Eliseu A.
author_facet Al-Zain, Afnan O.
Alboloshi, Elaf A.
Amir, Walaa A.
Alghilan, Maryam A.
Münchow, Eliseu A.
author_sort Al-Zain, Afnan O.
collection PubMed
description This study explores the effects of aging (thermal cycling and cyclic loading–TC/CL) and different light-curing unit (LCU) types on the volume characteristics and internal porosity of a bulk-fill resin-based composite restoration. Occlusal cavities (4 × 4 × 3 mm) were prepared on extracted human molars (n = 5). Tetric N-Bond Universal was applied, and the cavities were restored using Tetric-N-Ceram Bulk Fill. Photoactivation was performed using a quartz-tungsten halogen (QTH) or a multiple-emission peak light-emitting diode (MLED). Digital images for all restorations were obtained using microcomputed tomography (micro-CT) before (baseline) and after (post-aging) TC/CL (5,000 TC cycles in 5–55 °C baths and a dwell time of 30 s followed by 10,000 sinusoidal CL load cycles in an Instron B3000 at 2 Hz and 10–110 N) and storage (37 °C) for three months. For the micro-CT analysis, three-dimensional images were used to determine the restoration volume and internal porosity. Data were analyzed using a two-way ANOVA and Tukey’s test (p < 0.05). Restorations photoactivated with QTH exhibited a higher object volume than the LED group at baseline and in post-aging conditions without any significant differences in the other evaluated characteristics. All volume/porosity characteristics increased considerably after TC/CL aging, except for the object volume of the QTH group and the closed porosity of the MLED group. The change in all the volume/porosity characteristics between both LCU groups after TC/CL were not significantly different. Thus, the aging process simulated herein increased the volume and porosity characteristics of the bulk-fill restoration, and no significant differences were obtained between the QTH and MLED equipment.
format Online
Article
Text
id pubmed-9346940
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-93469402022-08-04 Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration Al-Zain, Afnan O. Alboloshi, Elaf A. Amir, Walaa A. Alghilan, Maryam A. Münchow, Eliseu A. Saudi Dent J Original Article This study explores the effects of aging (thermal cycling and cyclic loading–TC/CL) and different light-curing unit (LCU) types on the volume characteristics and internal porosity of a bulk-fill resin-based composite restoration. Occlusal cavities (4 × 4 × 3 mm) were prepared on extracted human molars (n = 5). Tetric N-Bond Universal was applied, and the cavities were restored using Tetric-N-Ceram Bulk Fill. Photoactivation was performed using a quartz-tungsten halogen (QTH) or a multiple-emission peak light-emitting diode (MLED). Digital images for all restorations were obtained using microcomputed tomography (micro-CT) before (baseline) and after (post-aging) TC/CL (5,000 TC cycles in 5–55 °C baths and a dwell time of 30 s followed by 10,000 sinusoidal CL load cycles in an Instron B3000 at 2 Hz and 10–110 N) and storage (37 °C) for three months. For the micro-CT analysis, three-dimensional images were used to determine the restoration volume and internal porosity. Data were analyzed using a two-way ANOVA and Tukey’s test (p < 0.05). Restorations photoactivated with QTH exhibited a higher object volume than the LED group at baseline and in post-aging conditions without any significant differences in the other evaluated characteristics. All volume/porosity characteristics increased considerably after TC/CL aging, except for the object volume of the QTH group and the closed porosity of the MLED group. The change in all the volume/porosity characteristics between both LCU groups after TC/CL were not significantly different. Thus, the aging process simulated herein increased the volume and porosity characteristics of the bulk-fill restoration, and no significant differences were obtained between the QTH and MLED equipment. Elsevier 2022-03 2022-01-19 /pmc/articles/PMC9346940/ /pubmed/35935721 http://dx.doi.org/10.1016/j.sdentj.2022.01.004 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Al-Zain, Afnan O.
Alboloshi, Elaf A.
Amir, Walaa A.
Alghilan, Maryam A.
Münchow, Eliseu A.
Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title_full Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title_fullStr Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title_full_unstemmed Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title_short Effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
title_sort effects of aging and light-curing unit type on the volume and internal porosity of bulk-fill resin composite restoration
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346940/
https://www.ncbi.nlm.nih.gov/pubmed/35935721
http://dx.doi.org/10.1016/j.sdentj.2022.01.004
work_keys_str_mv AT alzainafnano effectsofagingandlightcuringunittypeonthevolumeandinternalporosityofbulkfillresincompositerestoration
AT alboloshielafa effectsofagingandlightcuringunittypeonthevolumeandinternalporosityofbulkfillresincompositerestoration
AT amirwalaaa effectsofagingandlightcuringunittypeonthevolumeandinternalporosityofbulkfillresincompositerestoration
AT alghilanmaryama effectsofagingandlightcuringunittypeonthevolumeandinternalporosityofbulkfillresincompositerestoration
AT munchoweliseua effectsofagingandlightcuringunittypeonthevolumeandinternalporosityofbulkfillresincompositerestoration