Cargando…

External validation of inpatient neonatal mortality prediction models in high-mortality settings

BACKGROUND: Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in high-mortality, low-resource settings to...

Descripción completa

Detalles Bibliográficos
Autores principales: Tuti, Timothy, Collins, Gary, English, Mike, Aluvaala, Jalemba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9347100/
https://www.ncbi.nlm.nih.gov/pubmed/35918732
http://dx.doi.org/10.1186/s12916-022-02439-5
_version_ 1784761791275859968
author Tuti, Timothy
Collins, Gary
English, Mike
Aluvaala, Jalemba
author_facet Tuti, Timothy
Collins, Gary
English, Mike
Aluvaala, Jalemba
author_sort Tuti, Timothy
collection PubMed
description BACKGROUND: Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in high-mortality, low-resource settings to utilise data more likely to be available in these settings. In this study, we evaluate the predictive accuracy of two neonatal prediction models for all-cause in-hospital mortality. METHODS: We used retrospectively collected routine clinical data recorded by duty clinicians at admission from 16 Kenyan hospitals used to externally validate and update the SENSS and NETS models that were initially developed from the data from the largest Kenyan maternity hospital to predict in-hospital mortality. Model performance was evaluated by assessing discrimination and calibration. Discrimination, the ability of the model to differentiate between those with and without the outcome, was measured using the c-statistic. Calibration, the agreement between predictions from the model and what was observed, was measured using the calibration intercept and slope (with values of 0 and 1 denoting perfect calibration). RESULTS: At initial external validation, the estimated mortality risks from the original SENSS and NETS models were markedly overestimated with calibration intercepts of − 0.703 (95% CI − 0.738 to − 0.669) and − 1.109 (95% CI − 1.148 to − 1.069) and too extreme with calibration slopes of 0.565 (95% CI 0.552 to 0.577) and 0.466 (95% CI 0.451 to 0.480), respectively. After model updating, the calibration of the model improved. The updated SENSS and NETS models had calibration intercepts of 0.311 (95% CI 0.282 to 0.350) and 0.032 (95% CI − 0.002 to 0.066) and calibration slopes of 1.029 (95% CI 1.006 to 1.051) and 0.799 (95% CI 0.774 to 0.823), respectively, while showing good discrimination with c-statistics of 0.834 (95% CI 0.829 to 0.839) and 0.775 (95% CI 0.768 to 0.782), respectively. The overall calibration performance of the updated SENSS and NETS models was better than any existing neonatal in-hospital mortality prediction models externally validated for settings comparable to Kenya. CONCLUSION: Few prediction models undergo rigorous external validation. We show how external validation using data from multiple locations enables model updating and improving their performance and potential value. The improved models indicate it is possible to predict in-hospital mortality using either treatments or signs and symptoms derived from routine neonatal data from low-resource hospital settings also making possible their use for case-mix adjustment when contrasting similar hospital settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02439-5.
format Online
Article
Text
id pubmed-9347100
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-93471002022-08-04 External validation of inpatient neonatal mortality prediction models in high-mortality settings Tuti, Timothy Collins, Gary English, Mike Aluvaala, Jalemba BMC Med Research Article BACKGROUND: Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in high-mortality, low-resource settings to utilise data more likely to be available in these settings. In this study, we evaluate the predictive accuracy of two neonatal prediction models for all-cause in-hospital mortality. METHODS: We used retrospectively collected routine clinical data recorded by duty clinicians at admission from 16 Kenyan hospitals used to externally validate and update the SENSS and NETS models that were initially developed from the data from the largest Kenyan maternity hospital to predict in-hospital mortality. Model performance was evaluated by assessing discrimination and calibration. Discrimination, the ability of the model to differentiate between those with and without the outcome, was measured using the c-statistic. Calibration, the agreement between predictions from the model and what was observed, was measured using the calibration intercept and slope (with values of 0 and 1 denoting perfect calibration). RESULTS: At initial external validation, the estimated mortality risks from the original SENSS and NETS models were markedly overestimated with calibration intercepts of − 0.703 (95% CI − 0.738 to − 0.669) and − 1.109 (95% CI − 1.148 to − 1.069) and too extreme with calibration slopes of 0.565 (95% CI 0.552 to 0.577) and 0.466 (95% CI 0.451 to 0.480), respectively. After model updating, the calibration of the model improved. The updated SENSS and NETS models had calibration intercepts of 0.311 (95% CI 0.282 to 0.350) and 0.032 (95% CI − 0.002 to 0.066) and calibration slopes of 1.029 (95% CI 1.006 to 1.051) and 0.799 (95% CI 0.774 to 0.823), respectively, while showing good discrimination with c-statistics of 0.834 (95% CI 0.829 to 0.839) and 0.775 (95% CI 0.768 to 0.782), respectively. The overall calibration performance of the updated SENSS and NETS models was better than any existing neonatal in-hospital mortality prediction models externally validated for settings comparable to Kenya. CONCLUSION: Few prediction models undergo rigorous external validation. We show how external validation using data from multiple locations enables model updating and improving their performance and potential value. The improved models indicate it is possible to predict in-hospital mortality using either treatments or signs and symptoms derived from routine neonatal data from low-resource hospital settings also making possible their use for case-mix adjustment when contrasting similar hospital settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02439-5. BioMed Central 2022-08-03 /pmc/articles/PMC9347100/ /pubmed/35918732 http://dx.doi.org/10.1186/s12916-022-02439-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Tuti, Timothy
Collins, Gary
English, Mike
Aluvaala, Jalemba
External validation of inpatient neonatal mortality prediction models in high-mortality settings
title External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_full External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_fullStr External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_full_unstemmed External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_short External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_sort external validation of inpatient neonatal mortality prediction models in high-mortality settings
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9347100/
https://www.ncbi.nlm.nih.gov/pubmed/35918732
http://dx.doi.org/10.1186/s12916-022-02439-5
work_keys_str_mv AT tutitimothy externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT collinsgary externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT englishmike externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT aluvaalajalemba externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings