Cargando…

Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model

STUDY DESIGN. A porcine model. OBJECTIVE. The study aims to design a novel pedicle navigator based on micro-inertial navigation system (MINS) and bioelectrical impedance analysis (BIA) to assist place pedicle screw placement and validate the utility of the system in enhancing pedicle screw placement...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Wentao, Xie, Faqin, Zhao, Shuofeng, Lin, Songhui, He, Chaoqin, Wang, Zhiyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9348817/
https://www.ncbi.nlm.nih.gov/pubmed/35238856
http://dx.doi.org/10.1097/BRS.0000000000004348
_version_ 1784761996211650560
author Lin, Wentao
Xie, Faqin
Zhao, Shuofeng
Lin, Songhui
He, Chaoqin
Wang, Zhiyun
author_facet Lin, Wentao
Xie, Faqin
Zhao, Shuofeng
Lin, Songhui
He, Chaoqin
Wang, Zhiyun
author_sort Lin, Wentao
collection PubMed
description STUDY DESIGN. A porcine model. OBJECTIVE. The study aims to design a novel pedicle navigator based on micro-inertial navigation system (MINS) and bioelectrical impedance analysis (BIA) to assist place pedicle screw placement and validate the utility of the system in enhancing pedicle screw placement. SUMMARY OF BACKGROUND DATA. The incidence of pedicle screw malpositioning in complicated spinal surgery is still high. Procedures such as computed tomography image-guided navigation, and robot-assisted surgery have been used to improve the precision of pedicle screw placement, but it remains an unmet clinical need. METHODS. The miniaturized integrated framework containing MINS was mounted inside the hollow handle of the pedicle finder. The inner core was complemented by a high-intensity electrode for measuring bioelectric impedance. Twelve healthy male Wuzhishan minipigs of similar age and weight were used in this experiment and randomized to the MINS-BIA or freehand (FH) group. Pedicle screw placement was determined according to the modified Gertzbein–Robbins grading system on computed tomography images. An impedance detected by probe equal to the baseline value for soft tissue was defined as cortical bone perforation. RESULTS. A total of 216 screws were placed in 12 minipigs. There were 15 pedicle breaches in the navigator group and 31 in the FH group; the detection rates of these breaches were 14 of 15 (93.3%) and 25 of 31 (80.6%), respectively, with a statistically significant difference between groups. The mean offsets between the planned and postoperatively measured tilt angles of the screw trajectory were 4.5° ± 5.5° in the axial plane and 4.8° ± 3.3° in the sagittal plane with the navigator system and 7.0° ± 5.1° and 7.7° ± 4.7°, respectively, with the FH technique; the differences were statistically significant. CONCLUSION. A novel and portable navigator based on MINS and BIA could be beneficial for improving or maintaining accuracy while reducing overall radiation exposure.
format Online
Article
Text
id pubmed-9348817
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-93488172022-08-11 Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model Lin, Wentao Xie, Faqin Zhao, Shuofeng Lin, Songhui He, Chaoqin Wang, Zhiyun Spine (Phila Pa 1976) Basic Science STUDY DESIGN. A porcine model. OBJECTIVE. The study aims to design a novel pedicle navigator based on micro-inertial navigation system (MINS) and bioelectrical impedance analysis (BIA) to assist place pedicle screw placement and validate the utility of the system in enhancing pedicle screw placement. SUMMARY OF BACKGROUND DATA. The incidence of pedicle screw malpositioning in complicated spinal surgery is still high. Procedures such as computed tomography image-guided navigation, and robot-assisted surgery have been used to improve the precision of pedicle screw placement, but it remains an unmet clinical need. METHODS. The miniaturized integrated framework containing MINS was mounted inside the hollow handle of the pedicle finder. The inner core was complemented by a high-intensity electrode for measuring bioelectric impedance. Twelve healthy male Wuzhishan minipigs of similar age and weight were used in this experiment and randomized to the MINS-BIA or freehand (FH) group. Pedicle screw placement was determined according to the modified Gertzbein–Robbins grading system on computed tomography images. An impedance detected by probe equal to the baseline value for soft tissue was defined as cortical bone perforation. RESULTS. A total of 216 screws were placed in 12 minipigs. There were 15 pedicle breaches in the navigator group and 31 in the FH group; the detection rates of these breaches were 14 of 15 (93.3%) and 25 of 31 (80.6%), respectively, with a statistically significant difference between groups. The mean offsets between the planned and postoperatively measured tilt angles of the screw trajectory were 4.5° ± 5.5° in the axial plane and 4.8° ± 3.3° in the sagittal plane with the navigator system and 7.0° ± 5.1° and 7.7° ± 4.7°, respectively, with the FH technique; the differences were statistically significant. CONCLUSION. A novel and portable navigator based on MINS and BIA could be beneficial for improving or maintaining accuracy while reducing overall radiation exposure. Lippincott Williams & Wilkins 2022-08-15 2022-03-02 /pmc/articles/PMC9348817/ /pubmed/35238856 http://dx.doi.org/10.1097/BRS.0000000000004348 Text en © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Basic Science
Lin, Wentao
Xie, Faqin
Zhao, Shuofeng
Lin, Songhui
He, Chaoqin
Wang, Zhiyun
Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title_full Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title_fullStr Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title_full_unstemmed Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title_short Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
title_sort novel pedicle navigator based on micro inertial navigation system (mins) and bioelectric impedance analysis (bia) to facilitate pedicle screw placement in spine surgery: study in a porcine model
topic Basic Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9348817/
https://www.ncbi.nlm.nih.gov/pubmed/35238856
http://dx.doi.org/10.1097/BRS.0000000000004348
work_keys_str_mv AT linwentao novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel
AT xiefaqin novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel
AT zhaoshuofeng novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel
AT linsonghui novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel
AT hechaoqin novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel
AT wangzhiyun novelpediclenavigatorbasedonmicroinertialnavigationsystemminsandbioelectricimpedanceanalysisbiatofacilitatepediclescrewplacementinspinesurgerystudyinaporcinemodel