Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)

Due to their high sensitivity, simplicity, portability, self‐contained, and low cost, the development of electrochemical biosensors is a beneficial way to diagnose and anticipate many types of cancers. An electrochemical nanocomposite‐based aptasensor is fabricated for the determination of miRNA‐128...

Descripción completa

Detalles Bibliográficos
Autores principales: Dinani, Homayoon Soleimani, Pourmadadi, Mehrab, Yazdian, Fatemeh, Rashedi, Hamid, Ebrahimi, Seyed Ali Seyed, Shayeh, Javad Shabani, Ghorbani, Mehdi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9349134/
https://www.ncbi.nlm.nih.gov/pubmed/35936072
http://dx.doi.org/10.1002/elsc.202100170
_version_ 1784762063392866304
author Dinani, Homayoon Soleimani
Pourmadadi, Mehrab
Yazdian, Fatemeh
Rashedi, Hamid
Ebrahimi, Seyed Ali Seyed
Shayeh, Javad Shabani
Ghorbani, Mehdi
author_facet Dinani, Homayoon Soleimani
Pourmadadi, Mehrab
Yazdian, Fatemeh
Rashedi, Hamid
Ebrahimi, Seyed Ali Seyed
Shayeh, Javad Shabani
Ghorbani, Mehdi
author_sort Dinani, Homayoon Soleimani
collection PubMed
description Due to their high sensitivity, simplicity, portability, self‐contained, and low cost, the development of electrochemical biosensors is a beneficial way to diagnose and anticipate many types of cancers. An electrochemical nanocomposite‐based aptasensor is fabricated for the determination of miRNA‐128 concentration as the acute lymphoblastic leukemia (ALL) biomarker for the first time. The aptamer chains were immobilized on the surface of the glassy carbon electrode (GCE) through gold nanoparticles/magnetite/reduced graphene oxide (AuNPs/Fe(3)O(4)/RGO). Fast Fourier transform infrared (FTIR), X‐ray diffraction (XRD), vibrating sample magnetometer (VSM), and transmission electron microscopy (TEM) were used to characterize synthesized nanomaterials. Cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS) were used to characterize the modified GCE in both label‐free and labeled methods. The results indicate that the modified working electrode has high selectivity and for miRNA‐128 over other biomolecules. The hexacyanoferrate redox system typically operated at around 0.3 V (vs. Ag/AgCl), and the methylene blue redox system ran at about 0 V, were used as an electrochemical probe. The detection limit and linear detection range for hexacyanoferrate and methylene blue are 0.05346 fM, 0.1–0.9 fM, and 0.005483 fM, 0.01–0.09 fM, respectively. The stability and diffusion control analyses were performed as well. In both label‐free and labeled methods, the modified electron showed high selectivity for miRNA‐128. The use of methylene blue as a safer redox mediator caused miRNA‐128 to be detected with greater accuracy at low potentials in PBS media. The findings also show the substantial improvement in detection limit and linearity by using reduced graphene oxide‐magnetite‐gold nanoparticles that can be verified by comparing with previous studies on the detection of other miRNAs.
format Online
Article
Text
id pubmed-9349134
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93491342022-08-05 Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL) Dinani, Homayoon Soleimani Pourmadadi, Mehrab Yazdian, Fatemeh Rashedi, Hamid Ebrahimi, Seyed Ali Seyed Shayeh, Javad Shabani Ghorbani, Mehdi Eng Life Sci Research Articles Due to their high sensitivity, simplicity, portability, self‐contained, and low cost, the development of electrochemical biosensors is a beneficial way to diagnose and anticipate many types of cancers. An electrochemical nanocomposite‐based aptasensor is fabricated for the determination of miRNA‐128 concentration as the acute lymphoblastic leukemia (ALL) biomarker for the first time. The aptamer chains were immobilized on the surface of the glassy carbon electrode (GCE) through gold nanoparticles/magnetite/reduced graphene oxide (AuNPs/Fe(3)O(4)/RGO). Fast Fourier transform infrared (FTIR), X‐ray diffraction (XRD), vibrating sample magnetometer (VSM), and transmission electron microscopy (TEM) were used to characterize synthesized nanomaterials. Cyclic voltammetry (CV), square wave voltammetry (SWV), and electrochemical impedance spectroscopy (EIS) were used to characterize the modified GCE in both label‐free and labeled methods. The results indicate that the modified working electrode has high selectivity and for miRNA‐128 over other biomolecules. The hexacyanoferrate redox system typically operated at around 0.3 V (vs. Ag/AgCl), and the methylene blue redox system ran at about 0 V, were used as an electrochemical probe. The detection limit and linear detection range for hexacyanoferrate and methylene blue are 0.05346 fM, 0.1–0.9 fM, and 0.005483 fM, 0.01–0.09 fM, respectively. The stability and diffusion control analyses were performed as well. In both label‐free and labeled methods, the modified electron showed high selectivity for miRNA‐128. The use of methylene blue as a safer redox mediator caused miRNA‐128 to be detected with greater accuracy at low potentials in PBS media. The findings also show the substantial improvement in detection limit and linearity by using reduced graphene oxide‐magnetite‐gold nanoparticles that can be verified by comparing with previous studies on the detection of other miRNAs. John Wiley and Sons Inc. 2022-05-17 /pmc/articles/PMC9349134/ /pubmed/35936072 http://dx.doi.org/10.1002/elsc.202100170 Text en © 2022 Wiley‐VCH GmbH. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Dinani, Homayoon Soleimani
Pourmadadi, Mehrab
Yazdian, Fatemeh
Rashedi, Hamid
Ebrahimi, Seyed Ali Seyed
Shayeh, Javad Shabani
Ghorbani, Mehdi
Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title_full Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title_fullStr Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title_full_unstemmed Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title_short Fabrication of Au/Fe(3)O(4)/RGO based aptasensor for measurement of miRNA‐128, a biomarker for acute lymphoblastic leukemia (ALL)
title_sort fabrication of au/fe(3)o(4)/rgo based aptasensor for measurement of mirna‐128, a biomarker for acute lymphoblastic leukemia (all)
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9349134/
https://www.ncbi.nlm.nih.gov/pubmed/35936072
http://dx.doi.org/10.1002/elsc.202100170
work_keys_str_mv AT dinanihomayoonsoleimani fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT pourmadadimehrab fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT yazdianfatemeh fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT rashedihamid fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT ebrahimiseyedaliseyed fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT shayehjavadshabani fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall
AT ghorbanimehdi fabricationofaufe3o4rgobasedaptasensorformeasurementofmirna128abiomarkerforacutelymphoblasticleukemiaall