Cargando…

Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma

BACKGROUND: Training is essential to develop and maintain skills required to be a competent serologist, yet samples required to achieve this are often difficult to obtain. We evaluated the feasibility of SARS‐CoV‐2 peptide modified RBCs (1144‐kodecytes) to develop simulated antibody screening and id...

Descripción completa

Detalles Bibliográficos
Autores principales: Perry, Holly, Henry, Stephen M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9349923/
https://www.ncbi.nlm.nih.gov/pubmed/35761783
http://dx.doi.org/10.1111/trf.17004
_version_ 1784762163434356736
author Perry, Holly
Henry, Stephen M.
author_facet Perry, Holly
Henry, Stephen M.
author_sort Perry, Holly
collection PubMed
description BACKGROUND: Training is essential to develop and maintain skills required to be a competent serologist, yet samples required to achieve this are often difficult to obtain. We evaluated the feasibility of SARS‐CoV‐2 peptide modified RBCs (1144‐kodecytes) to develop simulated antibody screening and identification panels of reagent RBCs suitable for practical training, recognition, and grading of serologic reactions. STUDY DESIGN AND METHODS: RBCs from a single donor were modified into kodecytes using Kode Technology function‐spacer‐lipid constructs bearing a short SARS‐CoV‐2 peptide. Kodecytes and unmodified cells were then arranged in patterns representative of RBC antibody profiles as simulated antibody screening and identification reagent cell panels (SASID), and then tested against immune donor plasma samples containing SARS‐CoV‐2 antibodies. Manual tube and two different gel card serologic platforms were evaluated by routine techniques. SASID exemplars were created for antibodies including D, C(w), f (ce), Jk(a) (strong, weak, dosing), mixtures of D + E, Jk(a) + K, Fy(a) + E, high and low frequency antibodies and a warm IgG autoantibody. RESULTS: Kodecytes (positive reactions) and unmodified cells (negative) when arranged and tested in appropriate patterns in SASID panels were able to mimic IgG antibody reactions, and were capable of measuring both accuracy and precision in reaction grading. CONCLUSIONS: Kodecytes can be used to rapidly create in‐house simulated yet realistic antibody screening and identification panels suitable for large scale training in the recognition and grading of serologic reactions.
format Online
Article
Text
id pubmed-9349923
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-93499232022-08-04 Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma Perry, Holly Henry, Stephen M. Transfusion Original Research BACKGROUND: Training is essential to develop and maintain skills required to be a competent serologist, yet samples required to achieve this are often difficult to obtain. We evaluated the feasibility of SARS‐CoV‐2 peptide modified RBCs (1144‐kodecytes) to develop simulated antibody screening and identification panels of reagent RBCs suitable for practical training, recognition, and grading of serologic reactions. STUDY DESIGN AND METHODS: RBCs from a single donor were modified into kodecytes using Kode Technology function‐spacer‐lipid constructs bearing a short SARS‐CoV‐2 peptide. Kodecytes and unmodified cells were then arranged in patterns representative of RBC antibody profiles as simulated antibody screening and identification reagent cell panels (SASID), and then tested against immune donor plasma samples containing SARS‐CoV‐2 antibodies. Manual tube and two different gel card serologic platforms were evaluated by routine techniques. SASID exemplars were created for antibodies including D, C(w), f (ce), Jk(a) (strong, weak, dosing), mixtures of D + E, Jk(a) + K, Fy(a) + E, high and low frequency antibodies and a warm IgG autoantibody. RESULTS: Kodecytes (positive reactions) and unmodified cells (negative) when arranged and tested in appropriate patterns in SASID panels were able to mimic IgG antibody reactions, and were capable of measuring both accuracy and precision in reaction grading. CONCLUSIONS: Kodecytes can be used to rapidly create in‐house simulated yet realistic antibody screening and identification panels suitable for large scale training in the recognition and grading of serologic reactions. John Wiley & Sons, Inc. 2022-07-11 /pmc/articles/PMC9349923/ /pubmed/35761783 http://dx.doi.org/10.1111/trf.17004 Text en © 2022 The Authors. Transfusion published by Wiley Periodicals LLC on behalf of AABB. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Research
Perry, Holly
Henry, Stephen M.
Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title_full Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title_fullStr Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title_full_unstemmed Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title_short Simulated RBC antibody identification training panels created using SARS‐CoV‐2 kodecytes and immune plasma
title_sort simulated rbc antibody identification training panels created using sars‐cov‐2 kodecytes and immune plasma
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9349923/
https://www.ncbi.nlm.nih.gov/pubmed/35761783
http://dx.doi.org/10.1111/trf.17004
work_keys_str_mv AT perryholly simulatedrbcantibodyidentificationtrainingpanelscreatedusingsarscov2kodecytesandimmuneplasma
AT henrystephenm simulatedrbcantibodyidentificationtrainingpanelscreatedusingsarscov2kodecytesandimmuneplasma