Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System

Patient: Male, 35-year-old Final Diagnosis: Insulinoma Symptoms: Loss of consciousness Medication:— Clinical Procedure: — Specialty: Endocrinology and Metabolic • Metabolic Disorders and Diabetics OBJECTIVE: Rare disease BACKGROUND: Insulinoma presenting only with postprandial hypoglycemia is diffic...

Descripción completa

Detalles Bibliográficos
Autores principales: Aida, Azusa, Noto, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9350881/
https://www.ncbi.nlm.nih.gov/pubmed/35908172
http://dx.doi.org/10.12659/AJCR.936723
_version_ 1784762320751165440
author Aida, Azusa
Noto, Hiroshi
author_facet Aida, Azusa
Noto, Hiroshi
author_sort Aida, Azusa
collection PubMed
description Patient: Male, 35-year-old Final Diagnosis: Insulinoma Symptoms: Loss of consciousness Medication:— Clinical Procedure: — Specialty: Endocrinology and Metabolic • Metabolic Disorders and Diabetics OBJECTIVE: Rare disease BACKGROUND: Insulinoma presenting only with postprandial hypoglycemia is difficult to diagnose. Repeated episodes of hypoglycemia can lead to “hypoglycemia unawareness”, which can be even more dangerous and requires early detection and treatment. CASE REPORT: We report the case of a 35-year-old man with an insulinoma presenting as postprandial hypoglycemia who was treated with diazoxide and monitored using a factory-calibrated continuous glucose monitoring (CGM) system until surgery. When the patient initially presented with hypoglycemia, relative hyperinsulinemia was present. There were no obvious abnormal findings on imaging examination. Hypoglycemia was not repeated on endocrinological examination, even while fasting. Four months later, asymptomatic postprandial hypoglycemia of 48 mg/dL was incidentally detected. Although none of the conventional 3 indicators of relative hyperinsulinemia were met, an insulinoma was suspected based on the results of a fasting test. Computed tomography and magnetic resonance imaging showed a mass in the pancreatic uncinate process, and selective intra-arterial calcium infusion revealed high insulin levels in the same area, leading to a diagnosis of insulinoma. The patient was treated medically with diazoxide, using a factory-calibrated CGM system until surgery. Subsequently, pancreatic mass enucleation was performed, and pathological examination confirmed the diagnosis. After surgery, the hypoglycemia resolved, and the blood glucose level remained within a range of 100 to 180 mg/dL, without the use of diazoxide. CONCLUSIONS: A factory-calibrated CGM system is useful for evaluating the course of medical treatment, monitoring hypoglycemic episodes during the diagnostic period, detecting unconscious hypoglycemia, monitoring the response to medical treatment, and treating insulinoma after surgery.
format Online
Article
Text
id pubmed-9350881
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-93508812022-08-26 Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System Aida, Azusa Noto, Hiroshi Am J Case Rep Articles Patient: Male, 35-year-old Final Diagnosis: Insulinoma Symptoms: Loss of consciousness Medication:— Clinical Procedure: — Specialty: Endocrinology and Metabolic • Metabolic Disorders and Diabetics OBJECTIVE: Rare disease BACKGROUND: Insulinoma presenting only with postprandial hypoglycemia is difficult to diagnose. Repeated episodes of hypoglycemia can lead to “hypoglycemia unawareness”, which can be even more dangerous and requires early detection and treatment. CASE REPORT: We report the case of a 35-year-old man with an insulinoma presenting as postprandial hypoglycemia who was treated with diazoxide and monitored using a factory-calibrated continuous glucose monitoring (CGM) system until surgery. When the patient initially presented with hypoglycemia, relative hyperinsulinemia was present. There were no obvious abnormal findings on imaging examination. Hypoglycemia was not repeated on endocrinological examination, even while fasting. Four months later, asymptomatic postprandial hypoglycemia of 48 mg/dL was incidentally detected. Although none of the conventional 3 indicators of relative hyperinsulinemia were met, an insulinoma was suspected based on the results of a fasting test. Computed tomography and magnetic resonance imaging showed a mass in the pancreatic uncinate process, and selective intra-arterial calcium infusion revealed high insulin levels in the same area, leading to a diagnosis of insulinoma. The patient was treated medically with diazoxide, using a factory-calibrated CGM system until surgery. Subsequently, pancreatic mass enucleation was performed, and pathological examination confirmed the diagnosis. After surgery, the hypoglycemia resolved, and the blood glucose level remained within a range of 100 to 180 mg/dL, without the use of diazoxide. CONCLUSIONS: A factory-calibrated CGM system is useful for evaluating the course of medical treatment, monitoring hypoglycemic episodes during the diagnostic period, detecting unconscious hypoglycemia, monitoring the response to medical treatment, and treating insulinoma after surgery. International Scientific Literature, Inc. 2022-07-31 /pmc/articles/PMC9350881/ /pubmed/35908172 http://dx.doi.org/10.12659/AJCR.936723 Text en © Am J Case Rep, 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Articles
Aida, Azusa
Noto, Hiroshi
Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title_full Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title_fullStr Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title_full_unstemmed Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title_short Diagnosis and Treatment Course of Insulinoma Presenting as Hypoglycemia Unawareness Using a Factory-Calibrated Continuous Glucose Monitoring System
title_sort diagnosis and treatment course of insulinoma presenting as hypoglycemia unawareness using a factory-calibrated continuous glucose monitoring system
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9350881/
https://www.ncbi.nlm.nih.gov/pubmed/35908172
http://dx.doi.org/10.12659/AJCR.936723
work_keys_str_mv AT aidaazusa diagnosisandtreatmentcourseofinsulinomapresentingashypoglycemiaunawarenessusingafactorycalibratedcontinuousglucosemonitoringsystem
AT notohiroshi diagnosisandtreatmentcourseofinsulinomapresentingashypoglycemiaunawarenessusingafactorycalibratedcontinuousglucosemonitoringsystem