Safety and effectiveness of a novel dielectric mapping system: one-year, two chinese centers experiences
BACKGROUND: The KODEX-EPD system is a novel, dielectric three-dimensional mapping system. We aim to illustrate the feasibility, safety, and outcomes of ablation using the KODEX-EPD system. METHODS: A total of 272 patients with supraventricular arrhythmias were enrolled and underwent catheter ablatio...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9351078/ https://www.ncbi.nlm.nih.gov/pubmed/35922759 http://dx.doi.org/10.1186/s12872-022-02790-8 |
Sumario: | BACKGROUND: The KODEX-EPD system is a novel, dielectric three-dimensional mapping system. We aim to illustrate the feasibility, safety, and outcomes of ablation using the KODEX-EPD system. METHODS: A total of 272 patients with supraventricular arrhythmias were enrolled and underwent catheter ablation using the KODEX-EPD system from October 2020 to July 2021. The feasibility, safety, and ablation outcomes were analyzed. RESULTS: Of the enrolled patients, 15 (5.4%) had atrial tachycardia (AT), 88 (31.4%) had atrioventricular reentrant tachycardia (AVRT), 141 (50.4%) had atrioventricular nodal reentrant tachycardia (AVNRT), 34 (12.1%) had atrial fibrillation (AF), and 9 (3.2%) had atrial flutter (AFL). All AF patients included were first-do-pulmonary vein isolation (PVI); there were 26 paroxysmal AF and 8 persistent AF. All patients achieved immediate success of ablation. The mean follow-up duration was 11.8 ± 2.4 months. One patient (1.1%) in the AVRT subgroup and two patients (1.4%) in the AVNRT subgroup experienced recurrence. When considering a three-month blanking time, the estimated freedom of AF at one-year post-ablation with and without AADs was 75.7% and 70.4%, respectively. The Kaplan–Meier analysis showed no significant difference in the overall AF recurrence (log-rank; P = 0.931) or AAD-free AF recurrence (log-rank; P = 0.841) between RFCA and cryoablation. One patient had mild pulmonary embolism. None of the patients died or had a cerebrovascular event in the periprocedural period. CONCLUSIONS: This retrospective, two-center study demonstrated that catheter ablation of supraventricular arrhythmias using the KODEX-EPD system is feasible, safe, and effective. Trial registration Retrospectively registered. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-022-02790-8. |
---|