Cargando…
New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma
With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. In...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taiwan Food and Drug Administration
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9351789/ https://www.ncbi.nlm.nih.gov/pubmed/28911717 http://dx.doi.org/10.1016/j.jfda.2015.02.008 |
_version_ | 1784762507819220992 |
---|---|
author | Wani, Tanveer A. Zargar, Seema |
author_facet | Wani, Tanveer A. Zargar, Seema |
author_sort | Wani, Tanveer A. |
collection | PubMed |
description | With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB), in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS) telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA) using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v) with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995) and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans. |
format | Online Article Text |
id | pubmed-9351789 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Taiwan Food and Drug Administration |
record_format | MEDLINE/PubMed |
spelling | pubmed-93517892022-08-09 New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma Wani, Tanveer A. Zargar, Seema J Food Drug Anal Original Article With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB), in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS) telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA) using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v) with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995) and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans. Taiwan Food and Drug Administration 2015-03-26 /pmc/articles/PMC9351789/ /pubmed/28911717 http://dx.doi.org/10.1016/j.jfda.2015.02.008 Text en © 2015 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ). |
spellingShingle | Original Article Wani, Tanveer A. Zargar, Seema New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title | New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title_full | New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title_fullStr | New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title_full_unstemmed | New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title_short | New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
title_sort | new ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9351789/ https://www.ncbi.nlm.nih.gov/pubmed/28911717 http://dx.doi.org/10.1016/j.jfda.2015.02.008 |
work_keys_str_mv | AT wanitanveera newultraperformanceliquidchromatographytandemmassspectrometrymethodforthedeterminationofirbesartaninhumanplasma AT zargarseema newultraperformanceliquidchromatographytandemmassspectrometrymethodforthedeterminationofirbesartaninhumanplasma |