Cargando…
Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar
BACKGROUND: We modified the blind Seldinger technique by incorporating ultrasound guidance and the use of a multifunctional bladder paracentesis trocar for PD catheter (PDC) placement, which can be easily performed by a nephrologist and is a feasible technique. To compare success rates and safety of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9351854/ https://www.ncbi.nlm.nih.gov/pubmed/35945766 http://dx.doi.org/10.1097/MD.0000000000029694 |
_version_ | 1784762521870139392 |
---|---|
author | Li, Zhen Fang, Zheng Ding, HongYun Sun, JiYe Li, Yi Liu, Jie Yu, YunLu Zhang, JianBin |
author_facet | Li, Zhen Fang, Zheng Ding, HongYun Sun, JiYe Li, Yi Liu, Jie Yu, YunLu Zhang, JianBin |
author_sort | Li, Zhen |
collection | PubMed |
description | BACKGROUND: We modified the blind Seldinger technique by incorporating ultrasound guidance and the use of a multifunctional bladder paracentesis trocar for PD catheter (PDC) placement, which can be easily performed by a nephrologist and is a feasible technique. To compare success rates and safety of our modified percutaneous PD catheter placement technique to open surgery. METHODS: Two hundred and twelve stage-5 chronic kidney disease(CKD) patients receiving PD therapy from June 2016 to June 2019 were included, 105 patients treated by ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar (Group A) and 107 patients receiving open surgical placement (Group B). Outcomes of patients via either catheter placement technique were retrospectively compared. The clinical success rate as defined by proper catheter drainage within 4 weeks after placement, complication rates (both technical complications and infections), and 1-year catheter survival were compared. RESULTS: There was no significant difference in sex ratio, age, or previous abdominal surgery history between groups (P > .05). Both surgical time and incision length were significantly shorter in Group A than in Group B (P < .05). Clinical success rate was also higher inGroup A (P < .05). Moreover, Group A demonstrated lower overall complication rates (P < .05) and lower incidence rates of early peritonitis, initial drainage disorder, and peritubular leakage (all P < .05). One-year catheter survival was also higher in Group A (P < .05). CONCLUSION: Percutaneous placement of PD catheters using our modified technique demonstrates superior success rates and safety compared to open surgery. In addition, our modified technique can be a better alternative to traditional Seldinger percutaneous catheterization for its higher success rate and safety, more accurate positioning. |
format | Online Article Text |
id | pubmed-9351854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-93518542022-08-05 Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar Li, Zhen Fang, Zheng Ding, HongYun Sun, JiYe Li, Yi Liu, Jie Yu, YunLu Zhang, JianBin Medicine (Baltimore) Research Article BACKGROUND: We modified the blind Seldinger technique by incorporating ultrasound guidance and the use of a multifunctional bladder paracentesis trocar for PD catheter (PDC) placement, which can be easily performed by a nephrologist and is a feasible technique. To compare success rates and safety of our modified percutaneous PD catheter placement technique to open surgery. METHODS: Two hundred and twelve stage-5 chronic kidney disease(CKD) patients receiving PD therapy from June 2016 to June 2019 were included, 105 patients treated by ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar (Group A) and 107 patients receiving open surgical placement (Group B). Outcomes of patients via either catheter placement technique were retrospectively compared. The clinical success rate as defined by proper catheter drainage within 4 weeks after placement, complication rates (both technical complications and infections), and 1-year catheter survival were compared. RESULTS: There was no significant difference in sex ratio, age, or previous abdominal surgery history between groups (P > .05). Both surgical time and incision length were significantly shorter in Group A than in Group B (P < .05). Clinical success rate was also higher inGroup A (P < .05). Moreover, Group A demonstrated lower overall complication rates (P < .05) and lower incidence rates of early peritonitis, initial drainage disorder, and peritubular leakage (all P < .05). One-year catheter survival was also higher in Group A (P < .05). CONCLUSION: Percutaneous placement of PD catheters using our modified technique demonstrates superior success rates and safety compared to open surgery. In addition, our modified technique can be a better alternative to traditional Seldinger percutaneous catheterization for its higher success rate and safety, more accurate positioning. Lippincott Williams & Wilkins 2022-08-05 /pmc/articles/PMC9351854/ /pubmed/35945766 http://dx.doi.org/10.1097/MD.0000000000029694 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Li, Zhen Fang, Zheng Ding, HongYun Sun, JiYe Li, Yi Liu, Jie Yu, YunLu Zhang, JianBin Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title | Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title_full | Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title_fullStr | Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title_full_unstemmed | Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title_short | Success rates and safety of a modified percutaneous PD catheter placement technique: Ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
title_sort | success rates and safety of a modified percutaneous pd catheter placement technique: ultrasound-guided percutaneous placement of peritoneal dialysis catheters using a multifunctional bladder paracentesis trocar |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9351854/ https://www.ncbi.nlm.nih.gov/pubmed/35945766 http://dx.doi.org/10.1097/MD.0000000000029694 |
work_keys_str_mv | AT lizhen successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT fangzheng successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT dinghongyun successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT sunjiye successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT liyi successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT liujie successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT yuyunlu successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar AT zhangjianbin successratesandsafetyofamodifiedpercutaneouspdcatheterplacementtechniqueultrasoundguidedpercutaneousplacementofperitonealdialysiscathetersusingamultifunctionalbladderparacentesistrocar |