Accurate detection of atrial fibrillation events with R-R intervals from ECG signals

Atrial fibrillation (AF) is a typical category of arrhythmia. Clinical diagnosis of AF is based on the detection of abnormal R-R intervals (RRIs) with an electrocardiogram (ECG). Previous studies considered this detection problem as a classification problem and focused on extracting a number of feat...

Descripción completa

Detalles Bibliográficos
Autores principales: Duan, Junbo, Wang, Qing, Zhang, Bo, Liu, Chen, Li, Chenrui, Wang, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9352004/
https://www.ncbi.nlm.nih.gov/pubmed/35925979
http://dx.doi.org/10.1371/journal.pone.0271596
Descripción
Sumario:Atrial fibrillation (AF) is a typical category of arrhythmia. Clinical diagnosis of AF is based on the detection of abnormal R-R intervals (RRIs) with an electrocardiogram (ECG). Previous studies considered this detection problem as a classification problem and focused on extracting a number of features. In this study we demonstrate that instead of using any specific numerical characteristic as the input feature, the probability density of RRIs from ECG conserves comprehensive statistical information; hence, is a natural and efficient input feature for AF detection. Incorporated with a support vector machine as the classifier, results on the MIT-BIH database indicates that the proposed method is a simple and accurate approach for AF detection in terms of accuracy, sensitivity, and specificity.