Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report
BACKGROUND: Tension pneumothorax of the contralateral lung during single-lung ventilation (SLV) combined with artificial pneumothorax can cause cardiac arrest due to bilateral pneumothorax. If not rapidly diagnosed and managed, this condition can lead to sudden death. We describe the emergency handl...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9353903/ https://www.ncbi.nlm.nih.gov/pubmed/36158024 http://dx.doi.org/10.12998/wjcc.v10.i21.7592 |
_version_ | 1784762953666396160 |
---|---|
author | Zhang, Xu Song, Hai-Cheng Wang, Kui-Liang Ren, Yue-Yi |
author_facet | Zhang, Xu Song, Hai-Cheng Wang, Kui-Liang Ren, Yue-Yi |
author_sort | Zhang, Xu |
collection | PubMed |
description | BACKGROUND: Tension pneumothorax of the contralateral lung during single-lung ventilation (SLV) combined with artificial pneumothorax can cause cardiac arrest due to bilateral pneumothorax. If not rapidly diagnosed and managed, this condition can lead to sudden death. We describe the emergency handling procedures and rapid diagnostic methods for this critical emergency situation. CASE SUMMARY: We report a case of bilateral pneumothorax in a neonatal patient who underwent thoracoscopic esophageal atresia and tracheoesophageal fistula repair under the combined application of SLV and artificial pneumothorax. The patient suffered sudden cardiac arrest and received emergency treatment to revive her. The recognition of dangerous vital sign parameters, rapid evacuation of the artificial pneumothorax, and initiation of lateral position cardiopulmonary resuscitation while simultaneously removing the endotracheal tube to the main airway are critically important. Moreover, even though the sinus rhythm was restored, the patient’s continued tachycardia, reduced pulse pressure, and depressed pulse oximeter waveform were worrisome. We should highly suspect the possibility of pneumothorax and use rapid diagnostic methods to make judgment calls. Sometimes thoracoscopy can be used for rapid examination; if the mediastinum is observed to be shifted to the right, it may indicate tension pneumothorax. This condition can be immediately relieved by needle thoracentesis, ultimately allowing the safe completion of the surgical procedure. CONCLUSION: Bilateral pneumothorax during SLV combined with artificial pneumothorax is rare but can occur at any time in neonatal thoracoscopic surgery. Therefore, anesthesiologists should consider this possibility, be alert, and address this rare but critical complication in a timely manner. |
format | Online Article Text |
id | pubmed-9353903 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-93539032022-09-23 Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report Zhang, Xu Song, Hai-Cheng Wang, Kui-Liang Ren, Yue-Yi World J Clin Cases Case Report BACKGROUND: Tension pneumothorax of the contralateral lung during single-lung ventilation (SLV) combined with artificial pneumothorax can cause cardiac arrest due to bilateral pneumothorax. If not rapidly diagnosed and managed, this condition can lead to sudden death. We describe the emergency handling procedures and rapid diagnostic methods for this critical emergency situation. CASE SUMMARY: We report a case of bilateral pneumothorax in a neonatal patient who underwent thoracoscopic esophageal atresia and tracheoesophageal fistula repair under the combined application of SLV and artificial pneumothorax. The patient suffered sudden cardiac arrest and received emergency treatment to revive her. The recognition of dangerous vital sign parameters, rapid evacuation of the artificial pneumothorax, and initiation of lateral position cardiopulmonary resuscitation while simultaneously removing the endotracheal tube to the main airway are critically important. Moreover, even though the sinus rhythm was restored, the patient’s continued tachycardia, reduced pulse pressure, and depressed pulse oximeter waveform were worrisome. We should highly suspect the possibility of pneumothorax and use rapid diagnostic methods to make judgment calls. Sometimes thoracoscopy can be used for rapid examination; if the mediastinum is observed to be shifted to the right, it may indicate tension pneumothorax. This condition can be immediately relieved by needle thoracentesis, ultimately allowing the safe completion of the surgical procedure. CONCLUSION: Bilateral pneumothorax during SLV combined with artificial pneumothorax is rare but can occur at any time in neonatal thoracoscopic surgery. Therefore, anesthesiologists should consider this possibility, be alert, and address this rare but critical complication in a timely manner. Baishideng Publishing Group Inc 2022-07-26 2022-07-26 /pmc/articles/PMC9353903/ /pubmed/36158024 http://dx.doi.org/10.12998/wjcc.v10.i21.7592 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
spellingShingle | Case Report Zhang, Xu Song, Hai-Cheng Wang, Kui-Liang Ren, Yue-Yi Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title | Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title_full | Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title_fullStr | Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title_full_unstemmed | Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title_short | Considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: A case report |
title_sort | considerations of single-lung ventilation in neonatal thoracoscopic surgery with cardiac arrest caused by bilateral pneumothorax: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9353903/ https://www.ncbi.nlm.nih.gov/pubmed/36158024 http://dx.doi.org/10.12998/wjcc.v10.i21.7592 |
work_keys_str_mv | AT zhangxu considerationsofsinglelungventilationinneonatalthoracoscopicsurgerywithcardiacarrestcausedbybilateralpneumothoraxacasereport AT songhaicheng considerationsofsinglelungventilationinneonatalthoracoscopicsurgerywithcardiacarrestcausedbybilateralpneumothoraxacasereport AT wangkuiliang considerationsofsinglelungventilationinneonatalthoracoscopicsurgerywithcardiacarrestcausedbybilateralpneumothoraxacasereport AT renyueyi considerationsofsinglelungventilationinneonatalthoracoscopicsurgerywithcardiacarrestcausedbybilateralpneumothoraxacasereport |