Cargando…

Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode

A new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4] arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode...

Descripción completa

Detalles Bibliográficos
Autores principales: Eren, Hilal, Uzun, Harun, Andac, Muberra, Bilir, Seda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taiwan Food and Drug Administration 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355004/
https://www.ncbi.nlm.nih.gov/pubmed/28911454
http://dx.doi.org/10.1016/j.jfda.2014.03.003
_version_ 1784763196703244288
author Eren, Hilal
Uzun, Harun
Andac, Muberra
Bilir, Seda
author_facet Eren, Hilal
Uzun, Harun
Andac, Muberra
Bilir, Seda
author_sort Eren, Hilal
collection PubMed
description A new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4] arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode, under steady-state conditions, exhibited a working concentration range of 1 × 10(−1) – 1 × 10(−6) mol/L with a near-Nernstian slope of 25.3 mV/ decade and a detection limit of 3.5 × 10(−7) mol/L. The electrode had a very short response time (<10 seconds) and good reproducibility at a working pH range of 4.0–6.5. The electrode was used for 4 months without any significant change in its sensitivity. The potentiometric performance of the electrode in partially nonaqueous medium [up to 20 % (v/v) alcohol] was found satisfactory. The performance of the prepared electrode for the analysis of beer samples using direct potentiometric method is very encouraging.
format Online
Article
Text
id pubmed-9355004
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Taiwan Food and Drug Administration
record_format MEDLINE/PubMed
spelling pubmed-93550042022-08-09 Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode Eren, Hilal Uzun, Harun Andac, Muberra Bilir, Seda J Food Drug Anal Original Article A new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4] arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode, under steady-state conditions, exhibited a working concentration range of 1 × 10(−1) – 1 × 10(−6) mol/L with a near-Nernstian slope of 25.3 mV/ decade and a detection limit of 3.5 × 10(−7) mol/L. The electrode had a very short response time (<10 seconds) and good reproducibility at a working pH range of 4.0–6.5. The electrode was used for 4 months without any significant change in its sensitivity. The potentiometric performance of the electrode in partially nonaqueous medium [up to 20 % (v/v) alcohol] was found satisfactory. The performance of the prepared electrode for the analysis of beer samples using direct potentiometric method is very encouraging. Taiwan Food and Drug Administration 2014-05-22 /pmc/articles/PMC9355004/ /pubmed/28911454 http://dx.doi.org/10.1016/j.jfda.2014.03.003 Text en © 2014 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Original Article
Eren, Hilal
Uzun, Harun
Andac, Muberra
Bilir, Seda
Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title_full Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title_fullStr Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title_full_unstemmed Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title_short Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
title_sort potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355004/
https://www.ncbi.nlm.nih.gov/pubmed/28911454
http://dx.doi.org/10.1016/j.jfda.2014.03.003
work_keys_str_mv AT erenhilal potentiometricmonitoringofcobaltinbeersamplebysolidcontactionselectiveelectrode
AT uzunharun potentiometricmonitoringofcobaltinbeersamplebysolidcontactionselectiveelectrode
AT andacmuberra potentiometricmonitoringofcobaltinbeersamplebysolidcontactionselectiveelectrode
AT bilirseda potentiometricmonitoringofcobaltinbeersamplebysolidcontactionselectiveelectrode