Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle

Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measur...

Descripción completa

Detalles Bibliográficos
Autores principales: Kouyoumdjian, João Aris, Graca, Carla Renata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355656/
https://www.ncbi.nlm.nih.gov/pubmed/35937059
http://dx.doi.org/10.3389/fneur.2022.957174
_version_ 1784763344037609472
author Kouyoumdjian, João Aris
Graca, Carla Renata
author_facet Kouyoumdjian, João Aris
Graca, Carla Renata
author_sort Kouyoumdjian, João Aris
collection PubMed
description Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measurement was taken using the intramuscular microaxonal stimulation technique in 32 healthy subjects. The mean MCD and the mean MCD of the 27th value from the 32 subjects had a normal distribution and were 19.79 ± 2.72 μs and 26.88 ± 3.56 μs, respectively. The suggested limit for the mean MCD is ≥ 26 μs and for the individual values is > 34 μs.
format Online
Article
Text
id pubmed-9355656
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-93556562022-08-06 Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle Kouyoumdjian, João Aris Graca, Carla Renata Front Neurol Neurology Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measurement was taken using the intramuscular microaxonal stimulation technique in 32 healthy subjects. The mean MCD and the mean MCD of the 27th value from the 32 subjects had a normal distribution and were 19.79 ± 2.72 μs and 26.88 ± 3.56 μs, respectively. The suggested limit for the mean MCD is ≥ 26 μs and for the individual values is > 34 μs. Frontiers Media S.A. 2022-07-22 /pmc/articles/PMC9355656/ /pubmed/35937059 http://dx.doi.org/10.3389/fneur.2022.957174 Text en Copyright © 2022 Kouyoumdjian and Graca. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Kouyoumdjian, João Aris
Graca, Carla Renata
Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title_full Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title_fullStr Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title_full_unstemmed Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title_short Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
title_sort concentric needle jitter: reference values in stimulated tibialis anterior muscle
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355656/
https://www.ncbi.nlm.nih.gov/pubmed/35937059
http://dx.doi.org/10.3389/fneur.2022.957174
work_keys_str_mv AT kouyoumdjianjoaoaris concentricneedlejitterreferencevaluesinstimulatedtibialisanteriormuscle
AT gracacarlarenata concentricneedlejitterreferencevaluesinstimulatedtibialisanteriormuscle