Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle
Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measur...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355656/ https://www.ncbi.nlm.nih.gov/pubmed/35937059 http://dx.doi.org/10.3389/fneur.2022.957174 |
_version_ | 1784763344037609472 |
---|---|
author | Kouyoumdjian, João Aris Graca, Carla Renata |
author_facet | Kouyoumdjian, João Aris Graca, Carla Renata |
author_sort | Kouyoumdjian, João Aris |
collection | PubMed |
description | Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measurement was taken using the intramuscular microaxonal stimulation technique in 32 healthy subjects. The mean MCD and the mean MCD of the 27th value from the 32 subjects had a normal distribution and were 19.79 ± 2.72 μs and 26.88 ± 3.56 μs, respectively. The suggested limit for the mean MCD is ≥ 26 μs and for the individual values is > 34 μs. |
format | Online Article Text |
id | pubmed-9355656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93556562022-08-06 Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle Kouyoumdjian, João Aris Graca, Carla Renata Front Neurol Neurology Calculating the reference values for jitter parameters utilizing a disposable concentric needle have been already done for the most often tested muscles. Jitter, expressed as the mean consecutive difference (MCD), was measured in the Tibialis Anterior (TA), not routinely tested muscle. Jitter measurement was taken using the intramuscular microaxonal stimulation technique in 32 healthy subjects. The mean MCD and the mean MCD of the 27th value from the 32 subjects had a normal distribution and were 19.79 ± 2.72 μs and 26.88 ± 3.56 μs, respectively. The suggested limit for the mean MCD is ≥ 26 μs and for the individual values is > 34 μs. Frontiers Media S.A. 2022-07-22 /pmc/articles/PMC9355656/ /pubmed/35937059 http://dx.doi.org/10.3389/fneur.2022.957174 Text en Copyright © 2022 Kouyoumdjian and Graca. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Kouyoumdjian, João Aris Graca, Carla Renata Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title | Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title_full | Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title_fullStr | Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title_full_unstemmed | Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title_short | Concentric needle jitter: Reference values in stimulated Tibialis Anterior muscle |
title_sort | concentric needle jitter: reference values in stimulated tibialis anterior muscle |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355656/ https://www.ncbi.nlm.nih.gov/pubmed/35937059 http://dx.doi.org/10.3389/fneur.2022.957174 |
work_keys_str_mv | AT kouyoumdjianjoaoaris concentricneedlejitterreferencevaluesinstimulatedtibialisanteriormuscle AT gracacarlarenata concentricneedlejitterreferencevaluesinstimulatedtibialisanteriormuscle |