In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners

Objectives: Marginal and internal fit of restorations are two important clinical factors for assessing the quality and durability of computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated monolithic zirconia restorations. The purpose of this study was to evaluate the marginal and in...

Descripción completa

Detalles Bibliográficos
Autores principales: Khamverdi, Zahra, Najafrad, Elmira, Farhadian, Maryam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355843/
https://www.ncbi.nlm.nih.gov/pubmed/35965724
http://dx.doi.org/10.18502/fid.v18i2.5432
_version_ 1784763386011058176
author Khamverdi, Zahra
Najafrad, Elmira
Farhadian, Maryam
author_facet Khamverdi, Zahra
Najafrad, Elmira
Farhadian, Maryam
author_sort Khamverdi, Zahra
collection PubMed
description Objectives: Marginal and internal fit of restorations are two important clinical factors for assessing the quality and durability of computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated monolithic zirconia restorations. The purpose of this study was to evaluate the marginal and internal fit of CAD/CAM zirconia crowns with two different scanners (i3D scanner and 3Shape D700). Materials and Methods: Twelve extracted sound human posterior teeth were prepared for full zirconia crowns. Two different extraoral scanners namely i3D scanner and 3Shape D700 were used to digitize type IV gypsum casts poured from impressions. The crowns were milled from presintered monolithic zirconia blocks by a 5-axis milling machine. The replica technique and MIP4 microscopic image analysis software were utilized to measure the marginal and internal fit by a stereomicroscope at ×40 magnification. The collected data were analyzed by paired t-test. Results: The mean marginal gap was 203.62 μm with 3Shape D700 scanner and 241.07 μm with i3D scanner. The mean internal gap was 192.30 μm with 3Shape D700 scanner and 196.06 μm with i3D scanner. The results of paired t-test indicated that there was a statistically significant difference between the two scanners in marginal fit (P=0.04); while, there was no statistically significant difference in internal fit (P=0.761). Conclusion: Within the limitations of this study, the results showed that type of extraoral scanner affected the marginal fit of CAD/CAM fabricated crowns; however, it did not have a significant effect on their internal fit.
format Online
Article
Text
id pubmed-9355843
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-93558432022-08-12 In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners Khamverdi, Zahra Najafrad, Elmira Farhadian, Maryam Front Dent Original Article Objectives: Marginal and internal fit of restorations are two important clinical factors for assessing the quality and durability of computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated monolithic zirconia restorations. The purpose of this study was to evaluate the marginal and internal fit of CAD/CAM zirconia crowns with two different scanners (i3D scanner and 3Shape D700). Materials and Methods: Twelve extracted sound human posterior teeth were prepared for full zirconia crowns. Two different extraoral scanners namely i3D scanner and 3Shape D700 were used to digitize type IV gypsum casts poured from impressions. The crowns were milled from presintered monolithic zirconia blocks by a 5-axis milling machine. The replica technique and MIP4 microscopic image analysis software were utilized to measure the marginal and internal fit by a stereomicroscope at ×40 magnification. The collected data were analyzed by paired t-test. Results: The mean marginal gap was 203.62 μm with 3Shape D700 scanner and 241.07 μm with i3D scanner. The mean internal gap was 192.30 μm with 3Shape D700 scanner and 196.06 μm with i3D scanner. The results of paired t-test indicated that there was a statistically significant difference between the two scanners in marginal fit (P=0.04); while, there was no statistically significant difference in internal fit (P=0.761). Conclusion: Within the limitations of this study, the results showed that type of extraoral scanner affected the marginal fit of CAD/CAM fabricated crowns; however, it did not have a significant effect on their internal fit. Tehran University of Medical Sciences 2021-01-20 /pmc/articles/PMC9355843/ /pubmed/35965724 http://dx.doi.org/10.18502/fid.v18i2.5432 Text en Copyright © 2021 The Authors. Published by Tehran University of Medical Sciences. https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International license (https://creativecommons.org/licenses/by-nc/4.0/). Non-commercial uses of the work are permitted, provided the original work is properly cited.
spellingShingle Original Article
Khamverdi, Zahra
Najafrad, Elmira
Farhadian, Maryam
In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title_full In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title_fullStr In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title_full_unstemmed In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title_short In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners
title_sort in vitro comparison of marginal and internal fit of zirconia copings fabricated by one cad/cam system with two different scanners
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9355843/
https://www.ncbi.nlm.nih.gov/pubmed/35965724
http://dx.doi.org/10.18502/fid.v18i2.5432
work_keys_str_mv AT khamverdizahra invitrocomparisonofmarginalandinternalfitofzirconiacopingsfabricatedbyonecadcamsystemwithtwodifferentscanners
AT najafradelmira invitrocomparisonofmarginalandinternalfitofzirconiacopingsfabricatedbyonecadcamsystemwithtwodifferentscanners
AT farhadianmaryam invitrocomparisonofmarginalandinternalfitofzirconiacopingsfabricatedbyonecadcamsystemwithtwodifferentscanners