Cargando…
Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation
BACKGROUND: Stereotactic irradiation is one of the treatment modalities for intraocular uveal melanoma. The study’s purpose was to describe the background of stereotactic one-day session radiosurgery, how the comparison in the difference between the tumor volume measured values from the magnetic res...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9356474/ https://www.ncbi.nlm.nih.gov/pubmed/35931996 http://dx.doi.org/10.1186/s12886-022-02558-w |
_version_ | 1784763526070403072 |
---|---|
author | Furdova, Alena Furda, Robert Sramka, Miron Chorvath, Martin Rybar, Jan Vesely, Pavol Valaskova, Jela Siska, Vladimir |
author_facet | Furdova, Alena Furda, Robert Sramka, Miron Chorvath, Martin Rybar, Jan Vesely, Pavol Valaskova, Jela Siska, Vladimir |
author_sort | Furdova, Alena |
collection | PubMed |
description | BACKGROUND: Stereotactic irradiation is one of the treatment modalities for intraocular uveal melanoma. The study’s purpose was to describe the background of stereotactic one-day session radiosurgery, how the comparison in the difference between the tumor volume measured values from the magnetic resonance imaging (MRI) method and the ultrasound method was related to it, and which method was more precise to be used for tumor regression after irradiation. METHODS: The group of 147 patients with choroidal melanoma was treated by stereotactic irradiation on the linear accelerator with a single dose of 35.0 Gy. During the standard treatment process the uveal melanoma volumes, needed for dose calculation, were obtained using MRI from the individual stereotactic planning scheme and by ultrasound from the ultrasound device. All volumes were statistically compared using the paired t-test, and for the visualization purpose, the Bland-Altman plot was used. RESULTS: In the group of patients, it was 70 (47.6%) males and 77 (52.4%) females. The tumor volume median was from MRI equal to 0.44 cm(3) and from ultrasound equal to 0.53 cm(3). The difference between the ultrasound and the MRI volume measured values was statistically significant. However, the Bland-Altman plot clearly documents that the two methods are in agreement and can be used interchangeably. In most of the cases, the measured values of the ultrasound-calculated volume achieved slightly higher measured values. CONCLUSIONS: The calculation of the intraocular uveal tumor volume is a crucial part of the stereotactic irradiation treatment. The ultrasound volume measured values were in most of the cases higher than the measured values from the MRI. Although the methods are comparable and can be used interchangeably, we are recommending using the more precise MRI method not only during the treatment but also on later regular medical checks of tumor regression or progression. |
format | Online Article Text |
id | pubmed-9356474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-93564742022-08-07 Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation Furdova, Alena Furda, Robert Sramka, Miron Chorvath, Martin Rybar, Jan Vesely, Pavol Valaskova, Jela Siska, Vladimir BMC Ophthalmol Research BACKGROUND: Stereotactic irradiation is one of the treatment modalities for intraocular uveal melanoma. The study’s purpose was to describe the background of stereotactic one-day session radiosurgery, how the comparison in the difference between the tumor volume measured values from the magnetic resonance imaging (MRI) method and the ultrasound method was related to it, and which method was more precise to be used for tumor regression after irradiation. METHODS: The group of 147 patients with choroidal melanoma was treated by stereotactic irradiation on the linear accelerator with a single dose of 35.0 Gy. During the standard treatment process the uveal melanoma volumes, needed for dose calculation, were obtained using MRI from the individual stereotactic planning scheme and by ultrasound from the ultrasound device. All volumes were statistically compared using the paired t-test, and for the visualization purpose, the Bland-Altman plot was used. RESULTS: In the group of patients, it was 70 (47.6%) males and 77 (52.4%) females. The tumor volume median was from MRI equal to 0.44 cm(3) and from ultrasound equal to 0.53 cm(3). The difference between the ultrasound and the MRI volume measured values was statistically significant. However, the Bland-Altman plot clearly documents that the two methods are in agreement and can be used interchangeably. In most of the cases, the measured values of the ultrasound-calculated volume achieved slightly higher measured values. CONCLUSIONS: The calculation of the intraocular uveal tumor volume is a crucial part of the stereotactic irradiation treatment. The ultrasound volume measured values were in most of the cases higher than the measured values from the MRI. Although the methods are comparable and can be used interchangeably, we are recommending using the more precise MRI method not only during the treatment but also on later regular medical checks of tumor regression or progression. BioMed Central 2022-08-05 /pmc/articles/PMC9356474/ /pubmed/35931996 http://dx.doi.org/10.1186/s12886-022-02558-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Furdova, Alena Furda, Robert Sramka, Miron Chorvath, Martin Rybar, Jan Vesely, Pavol Valaskova, Jela Siska, Vladimir Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title | Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title_full | Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title_fullStr | Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title_full_unstemmed | Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title_short | Stereotactic irradiation on linear accelerator - ultrasound versus MRI in choroidal melanoma volume calculation |
title_sort | stereotactic irradiation on linear accelerator - ultrasound versus mri in choroidal melanoma volume calculation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9356474/ https://www.ncbi.nlm.nih.gov/pubmed/35931996 http://dx.doi.org/10.1186/s12886-022-02558-w |
work_keys_str_mv | AT furdovaalena stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT furdarobert stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT sramkamiron stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT chorvathmartin stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT rybarjan stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT veselypavol stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT valaskovajela stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation AT siskavladimir stereotacticirradiationonlinearacceleratorultrasoundversusmriinchoroidalmelanomavolumecalculation |