Cargando…
Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal
Recent outbreaks of infectious diseases such as Covid-19 that have fever as one of the symptoms drive the search for systems to track people with fever quickly and non-contact, also known as sanitary barriers. The use of non-contact infrared-based instruments, especially the infrared thermal imager,...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Authors. Published by Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9356631/ https://www.ncbi.nlm.nih.gov/pubmed/35958188 http://dx.doi.org/10.1016/j.sbsr.2022.100513 |
_version_ | 1784763561508077568 |
---|---|
author | Muniz, Pablo Rodrigues Simão, Josemar Nunes, Reginaldo Barbosa Campos, Hércules Lázaro Morais Santos, Natália Queirós Ninke, Andriele Lemos, João Thomaz |
author_facet | Muniz, Pablo Rodrigues Simão, Josemar Nunes, Reginaldo Barbosa Campos, Hércules Lázaro Morais Santos, Natália Queirós Ninke, Andriele Lemos, João Thomaz |
author_sort | Muniz, Pablo Rodrigues |
collection | PubMed |
description | Recent outbreaks of infectious diseases such as Covid-19 that have fever as one of the symptoms drive the search for systems to track people with fever quickly and non-contact, also known as sanitary barriers. The use of non-contact infrared-based instruments, especially the infrared thermal imager, has widely spread. However, the screening process has presented low performance. This article addresses the choice of regions of interest on the human face for the analysis of the individual's fever, deals with the temperature thresholds used for this analysis, as well as the way to issue the recommendation to screen the person or not. The data collection and statistical analysis of temperatures of 198 volunteers allowed us to study and define the most appropriate face regions as targets for these barriers, as well as the temperature thresholds to be used for screening for each of these regions. Besides, the paper presents a probabilistic method based on the metrological quality of the sanitary barrier to the emission of recommendation for screening potentially febrile people. The developed method was tested in feverish and non-febrile volunteers, showing complete assertiveness in the tested cases. |
format | Online Article Text |
id | pubmed-9356631 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Authors. Published by Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93566312022-08-07 Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal Muniz, Pablo Rodrigues Simão, Josemar Nunes, Reginaldo Barbosa Campos, Hércules Lázaro Morais Santos, Natália Queirós Ninke, Andriele Lemos, João Thomaz Sens Biosensing Res Article Recent outbreaks of infectious diseases such as Covid-19 that have fever as one of the symptoms drive the search for systems to track people with fever quickly and non-contact, also known as sanitary barriers. The use of non-contact infrared-based instruments, especially the infrared thermal imager, has widely spread. However, the screening process has presented low performance. This article addresses the choice of regions of interest on the human face for the analysis of the individual's fever, deals with the temperature thresholds used for this analysis, as well as the way to issue the recommendation to screen the person or not. The data collection and statistical analysis of temperatures of 198 volunteers allowed us to study and define the most appropriate face regions as targets for these barriers, as well as the temperature thresholds to be used for screening for each of these regions. Besides, the paper presents a probabilistic method based on the metrological quality of the sanitary barrier to the emission of recommendation for screening potentially febrile people. The developed method was tested in feverish and non-febrile volunteers, showing complete assertiveness in the tested cases. The Authors. Published by Elsevier B.V. 2022-08 2022-08-06 /pmc/articles/PMC9356631/ /pubmed/35958188 http://dx.doi.org/10.1016/j.sbsr.2022.100513 Text en © 2022 The Authors Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Muniz, Pablo Rodrigues Simão, Josemar Nunes, Reginaldo Barbosa Campos, Hércules Lázaro Morais Santos, Natália Queirós Ninke, Andriele Lemos, João Thomaz Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title | Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title_full | Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title_fullStr | Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title_full_unstemmed | Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title_short | Temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – A methodology proposal |
title_sort | temperature thresholds and screening of febrile people by non-contact measurement of the face using infrared thermography – a methodology proposal |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9356631/ https://www.ncbi.nlm.nih.gov/pubmed/35958188 http://dx.doi.org/10.1016/j.sbsr.2022.100513 |
work_keys_str_mv | AT munizpablorodrigues temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT simaojosemar temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT nunesreginaldobarbosa temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT camposherculeslazaromorais temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT santosnataliaqueiros temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT ninkeandriele temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal AT lemosjoaothomaz temperaturethresholdsandscreeningoffebrilepeoplebynoncontactmeasurementofthefaceusinginfraredthermographyamethodologyproposal |