Cargando…

To Investigate Whether Hematocrit Affects Thromboelastography Parameters

BACKGROUND: Thromboelastogram (TEG) is an experiment to detect coagulation function with whole blood. Red blood cell (RBC) is the most abundant component of blood. Whether RBC has an impact on the results of thromboelastogram? Study Design and Methods. The correlation between hematocrit (HCT) and TE...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Min, He, Keyu, Ye, Dong, Zhang, Qiang, Zhang, Zhengkang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9357726/
https://www.ncbi.nlm.nih.gov/pubmed/35965617
http://dx.doi.org/10.1155/2022/8877321
_version_ 1784763773999906816
author Zhang, Min
He, Keyu
Ye, Dong
Zhang, Qiang
Zhang, Zhengkang
author_facet Zhang, Min
He, Keyu
Ye, Dong
Zhang, Qiang
Zhang, Zhengkang
author_sort Zhang, Min
collection PubMed
description BACKGROUND: Thromboelastogram (TEG) is an experiment to detect coagulation function with whole blood. Red blood cell (RBC) is the most abundant component of blood. Whether RBC has an impact on the results of thromboelastogram? Study Design and Methods. The correlation between hematocrit (HCT) and TEG was analyzed. 17 samples were reconstituted with different HCT. They were tested separately. Correction tests were performed on 17 samples from patients with anemia. HCT was corrected to 0.40 in female and 0.45 in males. The correction formula was determined according to the experimental correction. RESULTS: HCT was negatively correlated with TEG parameters. As HCT increased, CI and angle decreased (P < 0.05, P < 0.001) and K increased (P < 0.001) in reconstituted samples. In the correction test, the angle measured value was 69.48 ± 4.98 and corrected value was 62.48 ± 6.25, MA measured value was 61.44 ± 7.10 and corrected value was 55.94 ± 7.12, K measured value was 1.45 ± 0.48 and corrected value was 2.11 ± 0.79, and CI measured value was 1.07 ± 1.67 and corrected value was −0.45 ± 1.64. There was a significant difference. The correction formulas of anemia were derived from the experimental correction results. K(Correction value) = (0.7903(∗)A(2) − 2.1803A + 2.8268)(∗)K(Measured value); Tan angle(Correction value) = Tan angle(Measured value)/(0.6596(∗)A(2) − 1.7478A + 2.4608); MA(Correction value) = MA(Measured value)/(0.1853ln (A) + 1.0197); CI(Correction value) = −0.6516R(Measured value) − 0.3772K(Correction value) + 0.1224MA(Correction value) + 0.0759angle(Correction value) − 7.7922. CONCLUSION: HCT has a negative impact on TEG parameters. Coagulation state of anemia patients is overestimated by TEG. The test results of anemia patients need to be corrected whether through the experimental correction or the formula correction.
format Online
Article
Text
id pubmed-9357726
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-93577262022-08-12 To Investigate Whether Hematocrit Affects Thromboelastography Parameters Zhang, Min He, Keyu Ye, Dong Zhang, Qiang Zhang, Zhengkang Contrast Media Mol Imaging Research Article BACKGROUND: Thromboelastogram (TEG) is an experiment to detect coagulation function with whole blood. Red blood cell (RBC) is the most abundant component of blood. Whether RBC has an impact on the results of thromboelastogram? Study Design and Methods. The correlation between hematocrit (HCT) and TEG was analyzed. 17 samples were reconstituted with different HCT. They were tested separately. Correction tests were performed on 17 samples from patients with anemia. HCT was corrected to 0.40 in female and 0.45 in males. The correction formula was determined according to the experimental correction. RESULTS: HCT was negatively correlated with TEG parameters. As HCT increased, CI and angle decreased (P < 0.05, P < 0.001) and K increased (P < 0.001) in reconstituted samples. In the correction test, the angle measured value was 69.48 ± 4.98 and corrected value was 62.48 ± 6.25, MA measured value was 61.44 ± 7.10 and corrected value was 55.94 ± 7.12, K measured value was 1.45 ± 0.48 and corrected value was 2.11 ± 0.79, and CI measured value was 1.07 ± 1.67 and corrected value was −0.45 ± 1.64. There was a significant difference. The correction formulas of anemia were derived from the experimental correction results. K(Correction value) = (0.7903(∗)A(2) − 2.1803A + 2.8268)(∗)K(Measured value); Tan angle(Correction value) = Tan angle(Measured value)/(0.6596(∗)A(2) − 1.7478A + 2.4608); MA(Correction value) = MA(Measured value)/(0.1853ln (A) + 1.0197); CI(Correction value) = −0.6516R(Measured value) − 0.3772K(Correction value) + 0.1224MA(Correction value) + 0.0759angle(Correction value) − 7.7922. CONCLUSION: HCT has a negative impact on TEG parameters. Coagulation state of anemia patients is overestimated by TEG. The test results of anemia patients need to be corrected whether through the experimental correction or the formula correction. Hindawi 2022-07-31 /pmc/articles/PMC9357726/ /pubmed/35965617 http://dx.doi.org/10.1155/2022/8877321 Text en Copyright © 2022 Min Zhang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Min
He, Keyu
Ye, Dong
Zhang, Qiang
Zhang, Zhengkang
To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title_full To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title_fullStr To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title_full_unstemmed To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title_short To Investigate Whether Hematocrit Affects Thromboelastography Parameters
title_sort to investigate whether hematocrit affects thromboelastography parameters
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9357726/
https://www.ncbi.nlm.nih.gov/pubmed/35965617
http://dx.doi.org/10.1155/2022/8877321
work_keys_str_mv AT zhangmin toinvestigatewhetherhematocritaffectsthromboelastographyparameters
AT hekeyu toinvestigatewhetherhematocritaffectsthromboelastographyparameters
AT yedong toinvestigatewhetherhematocritaffectsthromboelastographyparameters
AT zhangqiang toinvestigatewhetherhematocritaffectsthromboelastographyparameters
AT zhangzhengkang toinvestigatewhetherhematocritaffectsthromboelastographyparameters