Cargando…
Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy
OBJECTIVE: To investigate the effect of stereotactic radiotherapy (SBRT) combined with thermoplastic fixation on set-up error in breast cancer (BC) patients undergoing radiotherapy. METHODS: Ninety BC patients undergoing radiotherapy who were treated in our hospital (May 2019-May 2020) were selected...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9357780/ https://www.ncbi.nlm.nih.gov/pubmed/35959358 http://dx.doi.org/10.1155/2022/8370842 |
_version_ | 1784763785669509120 |
---|---|
author | Zhu, Luchao Liu, Jun Li, Yimin Yang, Qiaolu Wu, Qiong Lin, Qing Chen, Sijia |
author_facet | Zhu, Luchao Liu, Jun Li, Yimin Yang, Qiaolu Wu, Qiong Lin, Qing Chen, Sijia |
author_sort | Zhu, Luchao |
collection | PubMed |
description | OBJECTIVE: To investigate the effect of stereotactic radiotherapy (SBRT) combined with thermoplastic fixation on set-up error in breast cancer (BC) patients undergoing radiotherapy. METHODS: Ninety BC patients undergoing radiotherapy who were treated in our hospital (May 2019-May 2020) were selected as the research objects and equally divided into the experimental group and control group according to the order of hospitalization, with 45 patients in each group. The control group received conventional radiotherapy combined with breast bracket, and the experimental group received SBRT combined with thermoplastic fixation. The incidences of adverse reactions, 1-year survival rates, and set-up errors were compared between the two groups. RESULTS: Compared with the control group, the experimental group had much lower total incidence of adverse reactions and remarkably higher 1-year survival rate. The translational errors (X direction, Y direction, and Z direction), translational errors after rotation (X direction, Y direction, and Z direction), and rotation errors (X direction, Y direction, and Z direction) in the experimental group were obviously lower compared with those in the control group. CONCLUSION: Implementing SBRT combined with thermoplastic fixation in BC patients undergoing radiotherapy can effectively improve set-up efficiency and treatment accuracy and reduce set-up errors. Compared with the breast bracket, the combination of SBRT and thermoplastic fixation has higher application value, and further studies are conducive to providing patients with a better solution plan. |
format | Online Article Text |
id | pubmed-9357780 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-93577802022-08-10 Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy Zhu, Luchao Liu, Jun Li, Yimin Yang, Qiaolu Wu, Qiong Lin, Qing Chen, Sijia Comput Math Methods Med Research Article OBJECTIVE: To investigate the effect of stereotactic radiotherapy (SBRT) combined with thermoplastic fixation on set-up error in breast cancer (BC) patients undergoing radiotherapy. METHODS: Ninety BC patients undergoing radiotherapy who were treated in our hospital (May 2019-May 2020) were selected as the research objects and equally divided into the experimental group and control group according to the order of hospitalization, with 45 patients in each group. The control group received conventional radiotherapy combined with breast bracket, and the experimental group received SBRT combined with thermoplastic fixation. The incidences of adverse reactions, 1-year survival rates, and set-up errors were compared between the two groups. RESULTS: Compared with the control group, the experimental group had much lower total incidence of adverse reactions and remarkably higher 1-year survival rate. The translational errors (X direction, Y direction, and Z direction), translational errors after rotation (X direction, Y direction, and Z direction), and rotation errors (X direction, Y direction, and Z direction) in the experimental group were obviously lower compared with those in the control group. CONCLUSION: Implementing SBRT combined with thermoplastic fixation in BC patients undergoing radiotherapy can effectively improve set-up efficiency and treatment accuracy and reduce set-up errors. Compared with the breast bracket, the combination of SBRT and thermoplastic fixation has higher application value, and further studies are conducive to providing patients with a better solution plan. Hindawi 2022-07-31 /pmc/articles/PMC9357780/ /pubmed/35959358 http://dx.doi.org/10.1155/2022/8370842 Text en Copyright © 2022 Luchao Zhu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhu, Luchao Liu, Jun Li, Yimin Yang, Qiaolu Wu, Qiong Lin, Qing Chen, Sijia Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title | Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title_full | Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title_fullStr | Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title_full_unstemmed | Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title_short | Effect of Stereotactic Body Radiation Therapy Combined with Thermoplastic Fixation on Set-Up Errors in Breast Cancer Patients Undergoing Radiotherapy |
title_sort | effect of stereotactic body radiation therapy combined with thermoplastic fixation on set-up errors in breast cancer patients undergoing radiotherapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9357780/ https://www.ncbi.nlm.nih.gov/pubmed/35959358 http://dx.doi.org/10.1155/2022/8370842 |
work_keys_str_mv | AT zhuluchao effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT liujun effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT liyimin effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT yangqiaolu effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT wuqiong effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT linqing effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy AT chensijia effectofstereotacticbodyradiationtherapycombinedwiththermoplasticfixationonsetuperrorsinbreastcancerpatientsundergoingradiotherapy |