Cargando…
A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients
BACKGROUND: To compare the corneal biomechanical changes after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) with the same programmed optical zone (POZ) and similar refractive correction in patients with high myopia. METHODS: In this pro...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358498/ https://www.ncbi.nlm.nih.gov/pubmed/35957728 http://dx.doi.org/10.21037/atm-22-330 |
_version_ | 1784763943025115136 |
---|---|
author | He, Shengyu Luo, Yiqi Ye, Yiming Chen, Pei Liu, Chang Lei, Lei Zhuang, Jing Yu, Keming |
author_facet | He, Shengyu Luo, Yiqi Ye, Yiming Chen, Pei Liu, Chang Lei, Lei Zhuang, Jing Yu, Keming |
author_sort | He, Shengyu |
collection | PubMed |
description | BACKGROUND: To compare the corneal biomechanical changes after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) with the same programmed optical zone (POZ) and similar refractive correction in patients with high myopia. METHODS: In this prospective comparative study of the contralateral eye, 50 patients with high myopia with the same POZ and similar refractive correction who underwent SMILE in one eye and FS-LASIK in the other eye. Corneal biomechanical parameters and central corneal thickness (CCT) were measured using a Corvis ST II. All the patients were evaluated during follow-up visits beyond one year. Additionally, the corneal volume (CV) of the 10-mm diameter region was measured using a Pentacam. RESULTS: Ambrosio relational thickness to the horizontal profile (ARTh) and stiffness parameter A1 (SP-A1) decreased significantly after SMILE and FS-LASIK, whereas deformation amplitude ratio 2.0 mm (DA ratio 2.0 mm) and integrated radius (IR) increased significantly in both groups. The ARTh and SP-A1 were greater after SMILE than those after FS-LASIK at all the follow-up visits. In addition, there were greater amounts of CCT and CV after SMILE compared with that after FS-LASIK. Moreover, a positive correlation was found between ARTh and SP-A1 and postoperative CCT, while a negative correlation was found between IR and DA ratio 2.0 mm and postoperative CCT. A moderate correlation was observed between SP-A1 and CV after both SMILE and FS-LASIK, whereas there were no relationships between CV and ARTh, IR, or DA ratio 2.0 mm. CONCLUSIONS: SMILE had greater CCT, CV, ARTh, and SP-A1 than FS-LASIK in high myopia with the same POZ and similar refractive correction. Our results demonstrated that SMILE had lesser effect on corneal biomechanics than FS-LASIK in high myopia. KEYWORDS: Corneal biomechanics; Corvis ST II; small incision lenticule extraction (SMILE); femtosecond laser-assisted in situ keratomileusis (FS-LASIK); high myopia |
format | Online Article Text |
id | pubmed-9358498 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-93584982022-08-10 A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients He, Shengyu Luo, Yiqi Ye, Yiming Chen, Pei Liu, Chang Lei, Lei Zhuang, Jing Yu, Keming Ann Transl Med Original Article BACKGROUND: To compare the corneal biomechanical changes after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) with the same programmed optical zone (POZ) and similar refractive correction in patients with high myopia. METHODS: In this prospective comparative study of the contralateral eye, 50 patients with high myopia with the same POZ and similar refractive correction who underwent SMILE in one eye and FS-LASIK in the other eye. Corneal biomechanical parameters and central corneal thickness (CCT) were measured using a Corvis ST II. All the patients were evaluated during follow-up visits beyond one year. Additionally, the corneal volume (CV) of the 10-mm diameter region was measured using a Pentacam. RESULTS: Ambrosio relational thickness to the horizontal profile (ARTh) and stiffness parameter A1 (SP-A1) decreased significantly after SMILE and FS-LASIK, whereas deformation amplitude ratio 2.0 mm (DA ratio 2.0 mm) and integrated radius (IR) increased significantly in both groups. The ARTh and SP-A1 were greater after SMILE than those after FS-LASIK at all the follow-up visits. In addition, there were greater amounts of CCT and CV after SMILE compared with that after FS-LASIK. Moreover, a positive correlation was found between ARTh and SP-A1 and postoperative CCT, while a negative correlation was found between IR and DA ratio 2.0 mm and postoperative CCT. A moderate correlation was observed between SP-A1 and CV after both SMILE and FS-LASIK, whereas there were no relationships between CV and ARTh, IR, or DA ratio 2.0 mm. CONCLUSIONS: SMILE had greater CCT, CV, ARTh, and SP-A1 than FS-LASIK in high myopia with the same POZ and similar refractive correction. Our results demonstrated that SMILE had lesser effect on corneal biomechanics than FS-LASIK in high myopia. KEYWORDS: Corneal biomechanics; Corvis ST II; small incision lenticule extraction (SMILE); femtosecond laser-assisted in situ keratomileusis (FS-LASIK); high myopia AME Publishing Company 2022-07 /pmc/articles/PMC9358498/ /pubmed/35957728 http://dx.doi.org/10.21037/atm-22-330 Text en 2022 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article He, Shengyu Luo, Yiqi Ye, Yiming Chen, Pei Liu, Chang Lei, Lei Zhuang, Jing Yu, Keming A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title | A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title_full | A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title_fullStr | A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title_full_unstemmed | A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title_short | A comparative and prospective study of corneal biomechanics after SMILE and FS-LASIK performed on the contralateral eyes of high myopia patients |
title_sort | comparative and prospective study of corneal biomechanics after smile and fs-lasik performed on the contralateral eyes of high myopia patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358498/ https://www.ncbi.nlm.nih.gov/pubmed/35957728 http://dx.doi.org/10.21037/atm-22-330 |
work_keys_str_mv | AT heshengyu acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT luoyiqi acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT yeyiming acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT chenpei acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT liuchang acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT leilei acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT zhuangjing acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT yukeming acomparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT heshengyu comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT luoyiqi comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT yeyiming comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT chenpei comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT liuchang comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT leilei comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT zhuangjing comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients AT yukeming comparativeandprospectivestudyofcornealbiomechanicsaftersmileandfslasikperformedonthecontralateraleyesofhighmyopiapatients |