Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument
Objective: Evaluate the technical performance of the pre-analytical hemolysis-icterus-lipemia (HIL) check module on the ACL-TOP-750. Methods: 8433 routine coagulation samples were evaluated for HIL, the presence of clotting and low sample volume by both visual inspection and the pre-analytical HIL c...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358572/ https://www.ncbi.nlm.nih.gov/pubmed/35924377 http://dx.doi.org/10.1177/10760296221118483 |
_version_ | 1784763962155335680 |
---|---|
author | Yang, Mingyu Gui, Xiaoning Wang, Run Jiang, Shiju Zhou, Jing Chen, Jian Wang, Meiling Ning, Jiwei Miao, Linzi Liu, Hongwei Tang, Xiaomei Qu, Chenxue |
author_facet | Yang, Mingyu Gui, Xiaoning Wang, Run Jiang, Shiju Zhou, Jing Chen, Jian Wang, Meiling Ning, Jiwei Miao, Linzi Liu, Hongwei Tang, Xiaomei Qu, Chenxue |
author_sort | Yang, Mingyu |
collection | PubMed |
description | Objective: Evaluate the technical performance of the pre-analytical hemolysis-icterus-lipemia (HIL) check module on the ACL-TOP-750. Methods: 8433 routine coagulation samples were evaluated for HIL, the presence of clotting and low sample volume by both visual inspection and the pre-analytical HIL check module on the ACL-TOP-750. Results: 7726 samples were in agreement with both methods and 707 were not consistent. 356 samples with low volume were identified by visual inspection and 920 by the instrument (2.7 mL threshold). Visual inspection identified 56 lipemic samples while 13 of those with moderate or high lipemia were identified by the instrument. Visual inspection identified 47 hemolyzed samples while 7 with moderate or high hemolysis were identified by the instrument. Both visual inspection and the instrument identified 36 icteric samples. For triglyceride concentration and bilirubin concentration, there was good correlation between the ACL-TOP-750 and the DXC800 biochemistry analyzer. Among 30 samples with varying amounts of clotting, 27 were discovered by visual inspection and 3 were discovered by the instrument. Conclusion: The pre-analytical check module on the ACL-TOP-750 improved the detection rate of samples below the target 2.7 mL volume, and the accuracy in detection of HIL. However, the automated method could not replace visual assessment of clotting in samples. |
format | Online Article Text |
id | pubmed-9358572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-93585722022-08-10 Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument Yang, Mingyu Gui, Xiaoning Wang, Run Jiang, Shiju Zhou, Jing Chen, Jian Wang, Meiling Ning, Jiwei Miao, Linzi Liu, Hongwei Tang, Xiaomei Qu, Chenxue Clin Appl Thromb Hemost Original Manuscript Objective: Evaluate the technical performance of the pre-analytical hemolysis-icterus-lipemia (HIL) check module on the ACL-TOP-750. Methods: 8433 routine coagulation samples were evaluated for HIL, the presence of clotting and low sample volume by both visual inspection and the pre-analytical HIL check module on the ACL-TOP-750. Results: 7726 samples were in agreement with both methods and 707 were not consistent. 356 samples with low volume were identified by visual inspection and 920 by the instrument (2.7 mL threshold). Visual inspection identified 56 lipemic samples while 13 of those with moderate or high lipemia were identified by the instrument. Visual inspection identified 47 hemolyzed samples while 7 with moderate or high hemolysis were identified by the instrument. Both visual inspection and the instrument identified 36 icteric samples. For triglyceride concentration and bilirubin concentration, there was good correlation between the ACL-TOP-750 and the DXC800 biochemistry analyzer. Among 30 samples with varying amounts of clotting, 27 were discovered by visual inspection and 3 were discovered by the instrument. Conclusion: The pre-analytical check module on the ACL-TOP-750 improved the detection rate of samples below the target 2.7 mL volume, and the accuracy in detection of HIL. However, the automated method could not replace visual assessment of clotting in samples. SAGE Publications 2022-08-04 /pmc/articles/PMC9358572/ /pubmed/35924377 http://dx.doi.org/10.1177/10760296221118483 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Manuscript Yang, Mingyu Gui, Xiaoning Wang, Run Jiang, Shiju Zhou, Jing Chen, Jian Wang, Meiling Ning, Jiwei Miao, Linzi Liu, Hongwei Tang, Xiaomei Qu, Chenxue Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title | Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title_full | Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title_fullStr | Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title_full_unstemmed | Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title_short | Clinical Evaluation of the Pre-Analytical Capabilities of Hemostasis Instrument |
title_sort | clinical evaluation of the pre-analytical capabilities of hemostasis instrument |
topic | Original Manuscript |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358572/ https://www.ncbi.nlm.nih.gov/pubmed/35924377 http://dx.doi.org/10.1177/10760296221118483 |
work_keys_str_mv | AT yangmingyu clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT guixiaoning clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT wangrun clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT jiangshiju clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT zhoujing clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT chenjian clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT wangmeiling clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT ningjiwei clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT miaolinzi clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT liuhongwei clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT tangxiaomei clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument AT quchenxue clinicalevaluationofthepreanalyticalcapabilitiesofhemostasisinstrument |