Cargando…

Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method

The rGO/CeO(2)/FTO nanocomposite modified electrode was prepared by an electrochemical method. A simple and highly sensitive electrochemical sensing platform for electrochemical rGO and modified CeO(2) nanoribbons directly on FTO electrodes was developed. Simultaneous determination of Pb(2+) and Cd(...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Nan, Ren, Lu, Du, Guangyi, Liu, Jing, You, Xueqiu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358772/
https://www.ncbi.nlm.nih.gov/pubmed/36043082
http://dx.doi.org/10.1039/d2ra03153a
_version_ 1784764001803042816
author Zhao, Nan
Ren, Lu
Du, Guangyi
Liu, Jing
You, Xueqiu
author_facet Zhao, Nan
Ren, Lu
Du, Guangyi
Liu, Jing
You, Xueqiu
author_sort Zhao, Nan
collection PubMed
description The rGO/CeO(2)/FTO nanocomposite modified electrode was prepared by an electrochemical method. A simple and highly sensitive electrochemical sensing platform for electrochemical rGO and modified CeO(2) nanoribbons directly on FTO electrodes was developed. Simultaneous determination of Pb(2+) and Cd(2+) used the differential pulse anodic stripping voltammetry (DPASV) method. The method was simple to operate, and CeO(2) nanobelts could be obtained simultaneously by electrodeposition and reduction of GO without further processing. This is an environmentally friendly electrochemical method to obtain modified electrodes under mild conditions. The experimental results showed that the linear calibration curves of Pb(2+) and Cd(2+) are 1–300 and 0.2–500 μg L(−1), respectively. At the same time, no interference from other coexisting metal ions was found during the detection process, which proved that the modified electrode had good stability and repeatability.
format Online
Article
Text
id pubmed-9358772
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-93587722022-08-29 Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method Zhao, Nan Ren, Lu Du, Guangyi Liu, Jing You, Xueqiu RSC Adv Chemistry The rGO/CeO(2)/FTO nanocomposite modified electrode was prepared by an electrochemical method. A simple and highly sensitive electrochemical sensing platform for electrochemical rGO and modified CeO(2) nanoribbons directly on FTO electrodes was developed. Simultaneous determination of Pb(2+) and Cd(2+) used the differential pulse anodic stripping voltammetry (DPASV) method. The method was simple to operate, and CeO(2) nanobelts could be obtained simultaneously by electrodeposition and reduction of GO without further processing. This is an environmentally friendly electrochemical method to obtain modified electrodes under mild conditions. The experimental results showed that the linear calibration curves of Pb(2+) and Cd(2+) are 1–300 and 0.2–500 μg L(−1), respectively. At the same time, no interference from other coexisting metal ions was found during the detection process, which proved that the modified electrode had good stability and repeatability. The Royal Society of Chemistry 2022-08-08 /pmc/articles/PMC9358772/ /pubmed/36043082 http://dx.doi.org/10.1039/d2ra03153a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Zhao, Nan
Ren, Lu
Du, Guangyi
Liu, Jing
You, Xueqiu
Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title_full Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title_fullStr Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title_full_unstemmed Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title_short Determination of heavy metals in water using an FTO electrode modified with CeO(2)/rGO nanoribbons prepared by an electrochemical method
title_sort determination of heavy metals in water using an fto electrode modified with ceo(2)/rgo nanoribbons prepared by an electrochemical method
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358772/
https://www.ncbi.nlm.nih.gov/pubmed/36043082
http://dx.doi.org/10.1039/d2ra03153a
work_keys_str_mv AT zhaonan determinationofheavymetalsinwaterusinganftoelectrodemodifiedwithceo2rgonanoribbonspreparedbyanelectrochemicalmethod
AT renlu determinationofheavymetalsinwaterusinganftoelectrodemodifiedwithceo2rgonanoribbonspreparedbyanelectrochemicalmethod
AT duguangyi determinationofheavymetalsinwaterusinganftoelectrodemodifiedwithceo2rgonanoribbonspreparedbyanelectrochemicalmethod
AT liujing determinationofheavymetalsinwaterusinganftoelectrodemodifiedwithceo2rgonanoribbonspreparedbyanelectrochemicalmethod
AT youxueqiu determinationofheavymetalsinwaterusinganftoelectrodemodifiedwithceo2rgonanoribbonspreparedbyanelectrochemicalmethod