Cargando…

Bioprosthesis in aortic valve replacement: long-term inflammatory response and functionality

BACKGROUND: The evaluation of long-term inflammatory response and function in postoperative patients with aortic valve replacement (AVR) deserves special analysis because it is important to try to prevent reoperation and improve durability and functionality of the prostheses. It is our objective MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Saucedo-Orozco, Huitzilihuitl, Vargas-Barron, Jesus, Márquez-Velazco, Ricardo, Farjat-Pasos, Julio Iván, Martinez-Zavala, Karla Susana, Jiménez-Rojas, Valentin, Criales-Vera, Sergio Andres, Arias-Godínez, Jose Antonio, Fuentevilla-Alvarez, Giovanni, Guarner-Lans, Veronica, Perez-Torres, Israel, Melendez-Ramirez, Gabriela, Sanchez Perez, Tomas Efrain, Soto, Maria Elena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358956/
https://www.ncbi.nlm.nih.gov/pubmed/35926961
http://dx.doi.org/10.1136/openhrt-2022-002065
Descripción
Sumario:BACKGROUND: The evaluation of long-term inflammatory response and function in postoperative patients with aortic valve replacement (AVR) deserves special analysis because it is important to try to prevent reoperation and improve durability and functionality of the prostheses. It is our objective METHODS: In this study, we included a cohort of patients with aortic valve damage treated by AVR with mechanical prosthesis, bio prosthesis and we included a control group. RESULTS: We found that IL-4 and osteopontin levels were higher in patients with mechanical vs biological prostheses (p=0.01 and p=0.04, respectively), osteoprotegerin (OPG) levels were decreased (p=0.01), women had lower levels of ET-1 and IL-6, (p=0.02) (p=0.04), respectively. Patients older than 60 years had decreased levels of IL-1ß p<0.001) and a higher concentration of IL-4 p<0.05). IL-1ß, OPG and TNFα were higher in patients with less than 5 years of evolution vs more than 10 years (p=0.004, p=0.02 and p=0.03, respectively). Factors such as age, gender, prosthetic and elevated IL-1B and ET-1 levels are associated with valve dysfunction prosthetic. These results indicate that the inflammatory involvement present prior to valve replacement may be perpetuated by various factors in the long term. CONCLUSIONS: The findings provide us with the opportunity to effectively treat patients with AVR in the postoperative period, which could prolong the functionality of the bio prostheses. TRIAL REGISTRATION NUMBER: NCT04557345.