Cargando…
The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359034/ https://www.ncbi.nlm.nih.gov/pubmed/35699203 http://dx.doi.org/10.1002/acm2.13698 |
_version_ | 1784764054333554688 |
---|---|
author | Cheung, Michael L. M. Chow, Vivian U. Y. Kan, Monica W. K. Chan, Anthony T. C. |
author_facet | Cheung, Michael L. M. Chow, Vivian U. Y. Kan, Monica W. K. Chan, Anthony T. C. |
author_sort | Cheung, Michael L. M. |
collection | PubMed |
description | PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto‐assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose‐to‐medium (D (m)) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D (98%), D (2%), and D (mean) of the PTV(69.96)_Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D (98%), 3% difference in D (2%), and 11.2% difference in D (mean) were observed in the worst cases for PTV(69.96). Similar trend was observed for the PTV(5940)_Air Cavity, in which the D (98%), D (2%), and D (mean) calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D (98%), D (2%), and D (mean) could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control. |
format | Online Article Text |
id | pubmed-9359034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93590342022-08-10 The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB Cheung, Michael L. M. Chow, Vivian U. Y. Kan, Monica W. K. Chan, Anthony T. C. J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto‐assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose‐to‐medium (D (m)) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D (98%), D (2%), and D (mean) of the PTV(69.96)_Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D (98%), 3% difference in D (2%), and 11.2% difference in D (mean) were observed in the worst cases for PTV(69.96). Similar trend was observed for the PTV(5940)_Air Cavity, in which the D (98%), D (2%), and D (mean) calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D (98%), D (2%), and D (mean) could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control. John Wiley and Sons Inc. 2022-06-14 /pmc/articles/PMC9359034/ /pubmed/35699203 http://dx.doi.org/10.1002/acm2.13698 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Cheung, Michael L. M. Chow, Vivian U. Y. Kan, Monica W. K. Chan, Anthony T. C. The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title | The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title_full | The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title_fullStr | The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title_full_unstemmed | The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title_short | The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB |
title_sort | effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (npc) using acuros xb |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359034/ https://www.ncbi.nlm.nih.gov/pubmed/35699203 http://dx.doi.org/10.1002/acm2.13698 |
work_keys_str_mv | AT cheungmichaellm theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT chowvivianuy theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT kanmonicawk theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT chananthonytc theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT cheungmichaellm effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT chowvivianuy effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT kanmonicawk effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb AT chananthonytc effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb |