Cargando…

The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB

PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐a...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheung, Michael L. M., Chow, Vivian U. Y., Kan, Monica W. K., Chan, Anthony T. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359034/
https://www.ncbi.nlm.nih.gov/pubmed/35699203
http://dx.doi.org/10.1002/acm2.13698
_version_ 1784764054333554688
author Cheung, Michael L. M.
Chow, Vivian U. Y.
Kan, Monica W. K.
Chan, Anthony T. C.
author_facet Cheung, Michael L. M.
Chow, Vivian U. Y.
Kan, Monica W. K.
Chan, Anthony T. C.
author_sort Cheung, Michael L. M.
collection PubMed
description PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto‐assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose‐to‐medium (D (m)) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D (98%), D (2%), and D (mean) of the PTV(69.96)_Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D (98%), 3% difference in D (2%), and 11.2% difference in D (mean) were observed in the worst cases for PTV(69.96). Similar trend was observed for the PTV(5940)_Air Cavity, in which the D (98%), D (2%), and D (mean) calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D (98%), D (2%), and D (mean) could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control.
format Online
Article
Text
id pubmed-9359034
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93590342022-08-10 The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB Cheung, Michael L. M. Chow, Vivian U. Y. Kan, Monica W. K. Chan, Anthony T. C. J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto‐assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto‐assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose‐to‐medium (D (m)) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D (98%), D (2%), and D (mean) of the PTV(69.96)_Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D (98%), 3% difference in D (2%), and 11.2% difference in D (mean) were observed in the worst cases for PTV(69.96). Similar trend was observed for the PTV(5940)_Air Cavity, in which the D (98%), D (2%), and D (mean) calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D (98%), D (2%), and D (mean) could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control. John Wiley and Sons Inc. 2022-06-14 /pmc/articles/PMC9359034/ /pubmed/35699203 http://dx.doi.org/10.1002/acm2.13698 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Cheung, Michael L. M.
Chow, Vivian U. Y.
Kan, Monica W. K.
Chan, Anthony T. C.
The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title_full The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title_fullStr The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title_full_unstemmed The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title_short The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB
title_sort effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (npc) using acuros xb
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359034/
https://www.ncbi.nlm.nih.gov/pubmed/35699203
http://dx.doi.org/10.1002/acm2.13698
work_keys_str_mv AT cheungmichaellm theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT chowvivianuy theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT kanmonicawk theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT chananthonytc theeffectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT cheungmichaellm effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT chowvivianuy effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT kanmonicawk effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb
AT chananthonytc effectofmaterialassignmentinnasalcavityondosecalculationfornasopharyngealcarcinomanpcusingacurosxb