Cargando…
Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique
A 65-year-old male with proliferative diabetic retinopathy (PDR) and non-clearing vitreous hemorrhage underwent 25G pars plana vitrectomy (PPV). A large disk of thick organized blood of 5 disk diameter (DD) size was encountered in subhyaloid space. All attempts including lower cut rates to remove th...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359220/ https://www.ncbi.nlm.nih.gov/pubmed/35648011 http://dx.doi.org/10.4103/ijo.IJO_3063_21 |
_version_ | 1784764094497161216 |
---|---|
author | Singh, Deependra V Reddy, Raja R Upadhyay, Awaneesh Sharma, Yog R |
author_facet | Singh, Deependra V Reddy, Raja R Upadhyay, Awaneesh Sharma, Yog R |
author_sort | Singh, Deependra V |
collection | PubMed |
description | A 65-year-old male with proliferative diabetic retinopathy (PDR) and non-clearing vitreous hemorrhage underwent 25G pars plana vitrectomy (PPV). A large disk of thick organized blood of 5 disk diameter (DD) size was encountered in subhyaloid space. All attempts including lower cut rates to remove this disk using a 25G cutter turned futile. We used a 20G fragmatome to safely remove this hard clot from vitreous cavity in 50 s. Surgical time for removal of similar clot of 3 DD by 25G cutter in another eye was 5 min. Removal of thick clotted subhyaloid blood by ultrasonic fragmentation during diabetic vitrectomy is a safe, faster, and useful maneuver. |
format | Online Article Text |
id | pubmed-9359220 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-93592202022-08-10 Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique Singh, Deependra V Reddy, Raja R Upadhyay, Awaneesh Sharma, Yog R Indian J Ophthalmol Surgical Technique A 65-year-old male with proliferative diabetic retinopathy (PDR) and non-clearing vitreous hemorrhage underwent 25G pars plana vitrectomy (PPV). A large disk of thick organized blood of 5 disk diameter (DD) size was encountered in subhyaloid space. All attempts including lower cut rates to remove this disk using a 25G cutter turned futile. We used a 20G fragmatome to safely remove this hard clot from vitreous cavity in 50 s. Surgical time for removal of similar clot of 3 DD by 25G cutter in another eye was 5 min. Removal of thick clotted subhyaloid blood by ultrasonic fragmentation during diabetic vitrectomy is a safe, faster, and useful maneuver. Wolters Kluwer - Medknow 2022-06 2022-05-31 /pmc/articles/PMC9359220/ /pubmed/35648011 http://dx.doi.org/10.4103/ijo.IJO_3063_21 Text en Copyright: © 2022 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Technique Singh, Deependra V Reddy, Raja R Upadhyay, Awaneesh Sharma, Yog R Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title | Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title_full | Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title_fullStr | Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title_full_unstemmed | Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title_short | Ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – A novel technique |
title_sort | ultrasonic fragmentation for removing thick organized clots during diabetic vitrectomy – a novel technique |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359220/ https://www.ncbi.nlm.nih.gov/pubmed/35648011 http://dx.doi.org/10.4103/ijo.IJO_3063_21 |
work_keys_str_mv | AT singhdeependrav ultrasonicfragmentationforremovingthickorganizedclotsduringdiabeticvitrectomyanoveltechnique AT reddyrajar ultrasonicfragmentationforremovingthickorganizedclotsduringdiabeticvitrectomyanoveltechnique AT upadhyayawaneesh ultrasonicfragmentationforremovingthickorganizedclotsduringdiabeticvitrectomyanoveltechnique AT sharmayogr ultrasonicfragmentationforremovingthickorganizedclotsduringdiabeticvitrectomyanoveltechnique |