Cargando…

The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study

The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart...

Descripción completa

Detalles Bibliográficos
Autores principales: Skog, Jilian, Rafie, Sally, Schnock, Kumiko O., Yoon, Catherine, Lipsitz, Stuart, Lew, Pauline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359779/
https://www.ncbi.nlm.nih.gov/pubmed/35344977
http://dx.doi.org/10.1097/PTS.0000000000000905
_version_ 1784764207073329152
author Skog, Jilian
Rafie, Sally
Schnock, Kumiko O.
Yoon, Catherine
Lipsitz, Stuart
Lew, Pauline
author_facet Skog, Jilian
Rafie, Sally
Schnock, Kumiko O.
Yoon, Catherine
Lipsitz, Stuart
Lew, Pauline
author_sort Skog, Jilian
collection PubMed
description The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart pump interoperability. Point prevalence methodology was used to collect data on medication administration and errors in adult inpatient settings. RESULTS: Observations were completed for 350 infusions preintervention (178 patients) and 367 postintervention (200 patients). Total errors significantly decreased from 401 (114.6 per 100 infusions) to 354 (96.5 per 100 infusions, P = 0.02). Administration errors decreased from 144 (41.1 per 100 infusions) to 119 (32.4 per 100 infusions, P = 0.12). Expired medication errors significantly reduced from 11 (3.1 per 100 infusions) to 2 (0.5 per 100 infusions, P = 0.02). Errors involving high-risk medications significantly reduced from 45 (12.8 per 100 infusions) to 25 (6.8 per 100 infusions, P = 0.01). Errors involving continuous medications significantly reduced from 44 (12.6 per 100 infusions) to 22 (6.0 per 100 infusions, P = 0.005). When comparing programming type, manual programming resulted in 115 (77.2%) of administration and user documentation errors compared with 34 errors (22.8%) that occurred when autoprogramming was used. Of these, errors involving high-risk medications reduced from 21 (84.0%) to 4 (16.0%) after using autoprogramming. CONCLUSIONS: Smart pump interoperability resulted in a 16% reduction in medication administration errors. Despite using dose error reduction software and autoprogramming, some types of errors persisted. Further studies are needed to understand how technology use can be optimized.
format Online
Article
Text
id pubmed-9359779
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-93597792022-08-11 The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study Skog, Jilian Rafie, Sally Schnock, Kumiko O. Yoon, Catherine Lipsitz, Stuart Lew, Pauline J Patient Saf Original Studies The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart pump interoperability. Point prevalence methodology was used to collect data on medication administration and errors in adult inpatient settings. RESULTS: Observations were completed for 350 infusions preintervention (178 patients) and 367 postintervention (200 patients). Total errors significantly decreased from 401 (114.6 per 100 infusions) to 354 (96.5 per 100 infusions, P = 0.02). Administration errors decreased from 144 (41.1 per 100 infusions) to 119 (32.4 per 100 infusions, P = 0.12). Expired medication errors significantly reduced from 11 (3.1 per 100 infusions) to 2 (0.5 per 100 infusions, P = 0.02). Errors involving high-risk medications significantly reduced from 45 (12.8 per 100 infusions) to 25 (6.8 per 100 infusions, P = 0.01). Errors involving continuous medications significantly reduced from 44 (12.6 per 100 infusions) to 22 (6.0 per 100 infusions, P = 0.005). When comparing programming type, manual programming resulted in 115 (77.2%) of administration and user documentation errors compared with 34 errors (22.8%) that occurred when autoprogramming was used. Of these, errors involving high-risk medications reduced from 21 (84.0%) to 4 (16.0%) after using autoprogramming. CONCLUSIONS: Smart pump interoperability resulted in a 16% reduction in medication administration errors. Despite using dose error reduction software and autoprogramming, some types of errors persisted. Further studies are needed to understand how technology use can be optimized. Lippincott Williams & Wilkins 2022-04 2021-12-28 /pmc/articles/PMC9359779/ /pubmed/35344977 http://dx.doi.org/10.1097/PTS.0000000000000905 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Original Studies
Skog, Jilian
Rafie, Sally
Schnock, Kumiko O.
Yoon, Catherine
Lipsitz, Stuart
Lew, Pauline
The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title_full The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title_fullStr The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title_full_unstemmed The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title_short The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
title_sort impact of smart pump interoperability on errors in intravenous infusion administrations: a multihospital before and after study
topic Original Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359779/
https://www.ncbi.nlm.nih.gov/pubmed/35344977
http://dx.doi.org/10.1097/PTS.0000000000000905
work_keys_str_mv AT skogjilian theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT rafiesally theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT schnockkumikoo theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT yooncatherine theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT lipsitzstuart theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT lewpauline theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT skogjilian impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT rafiesally impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT schnockkumikoo impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT yooncatherine impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT lipsitzstuart impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy
AT lewpauline impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy