Cargando…
The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study
The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359779/ https://www.ncbi.nlm.nih.gov/pubmed/35344977 http://dx.doi.org/10.1097/PTS.0000000000000905 |
_version_ | 1784764207073329152 |
---|---|
author | Skog, Jilian Rafie, Sally Schnock, Kumiko O. Yoon, Catherine Lipsitz, Stuart Lew, Pauline |
author_facet | Skog, Jilian Rafie, Sally Schnock, Kumiko O. Yoon, Catherine Lipsitz, Stuart Lew, Pauline |
author_sort | Skog, Jilian |
collection | PubMed |
description | The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart pump interoperability. Point prevalence methodology was used to collect data on medication administration and errors in adult inpatient settings. RESULTS: Observations were completed for 350 infusions preintervention (178 patients) and 367 postintervention (200 patients). Total errors significantly decreased from 401 (114.6 per 100 infusions) to 354 (96.5 per 100 infusions, P = 0.02). Administration errors decreased from 144 (41.1 per 100 infusions) to 119 (32.4 per 100 infusions, P = 0.12). Expired medication errors significantly reduced from 11 (3.1 per 100 infusions) to 2 (0.5 per 100 infusions, P = 0.02). Errors involving high-risk medications significantly reduced from 45 (12.8 per 100 infusions) to 25 (6.8 per 100 infusions, P = 0.01). Errors involving continuous medications significantly reduced from 44 (12.6 per 100 infusions) to 22 (6.0 per 100 infusions, P = 0.005). When comparing programming type, manual programming resulted in 115 (77.2%) of administration and user documentation errors compared with 34 errors (22.8%) that occurred when autoprogramming was used. Of these, errors involving high-risk medications reduced from 21 (84.0%) to 4 (16.0%) after using autoprogramming. CONCLUSIONS: Smart pump interoperability resulted in a 16% reduction in medication administration errors. Despite using dose error reduction software and autoprogramming, some types of errors persisted. Further studies are needed to understand how technology use can be optimized. |
format | Online Article Text |
id | pubmed-9359779 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-93597792022-08-11 The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study Skog, Jilian Rafie, Sally Schnock, Kumiko O. Yoon, Catherine Lipsitz, Stuart Lew, Pauline J Patient Saf Original Studies The objective of this study was to assess the frequency, type, and severity of errors associated with intravenous medication administration before and after smart pump interoperability. METHODS: We conducted an observational study at a community healthcare system before and after implementing smart pump interoperability. Point prevalence methodology was used to collect data on medication administration and errors in adult inpatient settings. RESULTS: Observations were completed for 350 infusions preintervention (178 patients) and 367 postintervention (200 patients). Total errors significantly decreased from 401 (114.6 per 100 infusions) to 354 (96.5 per 100 infusions, P = 0.02). Administration errors decreased from 144 (41.1 per 100 infusions) to 119 (32.4 per 100 infusions, P = 0.12). Expired medication errors significantly reduced from 11 (3.1 per 100 infusions) to 2 (0.5 per 100 infusions, P = 0.02). Errors involving high-risk medications significantly reduced from 45 (12.8 per 100 infusions) to 25 (6.8 per 100 infusions, P = 0.01). Errors involving continuous medications significantly reduced from 44 (12.6 per 100 infusions) to 22 (6.0 per 100 infusions, P = 0.005). When comparing programming type, manual programming resulted in 115 (77.2%) of administration and user documentation errors compared with 34 errors (22.8%) that occurred when autoprogramming was used. Of these, errors involving high-risk medications reduced from 21 (84.0%) to 4 (16.0%) after using autoprogramming. CONCLUSIONS: Smart pump interoperability resulted in a 16% reduction in medication administration errors. Despite using dose error reduction software and autoprogramming, some types of errors persisted. Further studies are needed to understand how technology use can be optimized. Lippincott Williams & Wilkins 2022-04 2021-12-28 /pmc/articles/PMC9359779/ /pubmed/35344977 http://dx.doi.org/10.1097/PTS.0000000000000905 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Studies Skog, Jilian Rafie, Sally Schnock, Kumiko O. Yoon, Catherine Lipsitz, Stuart Lew, Pauline The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title | The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title_full | The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title_fullStr | The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title_full_unstemmed | The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title_short | The Impact of Smart Pump Interoperability on Errors in Intravenous Infusion Administrations: A Multihospital Before and After Study |
title_sort | impact of smart pump interoperability on errors in intravenous infusion administrations: a multihospital before and after study |
topic | Original Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359779/ https://www.ncbi.nlm.nih.gov/pubmed/35344977 http://dx.doi.org/10.1097/PTS.0000000000000905 |
work_keys_str_mv | AT skogjilian theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT rafiesally theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT schnockkumikoo theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT yooncatherine theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT lipsitzstuart theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT lewpauline theimpactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT skogjilian impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT rafiesally impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT schnockkumikoo impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT yooncatherine impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT lipsitzstuart impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy AT lewpauline impactofsmartpumpinteroperabilityonerrorsinintravenousinfusionadministrationsamultihospitalbeforeandafterstudy |