Cargando…
Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation
BACKGROUND: The right fibrous trigone, which the His bundle penetrates, is part of the subaortic area adjacent to the membranous septum. Structural alterations of the right fibrous trigone may cause conduction disturbance as a result of compression in this area after transcatheter aortic valve impla...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Society of Cardiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361055/ https://www.ncbi.nlm.nih.gov/pubmed/35791709 http://dx.doi.org/10.5152/AnatolJCardiol.2022.987 |
_version_ | 1784764448006733824 |
---|---|
author | Aslan, Serkan Türkvatan, Aysel Topel, Çağdaş Güner, Ahmet Rıza Demir, Ali Kahraman, Serkan Çelik, Ömer Ertürk, Mehmet |
author_facet | Aslan, Serkan Türkvatan, Aysel Topel, Çağdaş Güner, Ahmet Rıza Demir, Ali Kahraman, Serkan Çelik, Ömer Ertürk, Mehmet |
author_sort | Aslan, Serkan |
collection | PubMed |
description | BACKGROUND: The right fibrous trigone, which the His bundle penetrates, is part of the subaortic area adjacent to the membranous septum. Structural alterations of the right fibrous trigone may cause conduction disturbance as a result of compression in this area after transcatheter aortic valve implantation. This study analyzed the hypothesis of whether imaging parameters of the RFT could predict the risk of conduction disturbance after transcatheter aortic valve implantation. METHODS: We retrospectively examined 209 patients who underwent transfemoral transcatheter aortic valve implantationat a tertiary cardiac center. The different valve models were divided into 2 groups: self-expanding valve and balloon-expandable valve. Using pre-procedure computed tomography, we evaluated for the alterations of the right fibrous trigone. RESULTS: New conduction disturbance was seen in 75 of 209 (35.8%) patients. Receiver operating characteristics plots displayed a right fibrous trigone density of −6 Hounsfield unit for SEV and −16 Hounsfield unit for balloon-expandable valve as the optimal cutoff points for prediction conduction disturbance. In multiple regression analyses, the high density of RFT emerged as an independent predictor of conduction disturbance in both the self-expanding valve (odds ratio: 1.01, 95% CI: 1.01 to 1.02, P = 0.035) and balloon-expandable valve (odds ratio: 1.01, 95% CI: 1.01 to 1.03, P = 0.017) groups. A shorter membranous septum length and a greater implantation depth were also found to be significantly associated with a higher incidence of conduction disturbance in both transcatheter aortic valve implantation groups. CONCLUSION: High density of right fibrous trigone is independently associated with conduction disturbance after transcatheter aortic valve implantation, and its pre-procedure computed tomography evaluation can help predict the new-onset of conduction disturbance. |
format | Online Article Text |
id | pubmed-9361055 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Turkish Society of Cardiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-93610552022-08-18 Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation Aslan, Serkan Türkvatan, Aysel Topel, Çağdaş Güner, Ahmet Rıza Demir, Ali Kahraman, Serkan Çelik, Ömer Ertürk, Mehmet Anatol J Cardiol Original Investigation BACKGROUND: The right fibrous trigone, which the His bundle penetrates, is part of the subaortic area adjacent to the membranous septum. Structural alterations of the right fibrous trigone may cause conduction disturbance as a result of compression in this area after transcatheter aortic valve implantation. This study analyzed the hypothesis of whether imaging parameters of the RFT could predict the risk of conduction disturbance after transcatheter aortic valve implantation. METHODS: We retrospectively examined 209 patients who underwent transfemoral transcatheter aortic valve implantationat a tertiary cardiac center. The different valve models were divided into 2 groups: self-expanding valve and balloon-expandable valve. Using pre-procedure computed tomography, we evaluated for the alterations of the right fibrous trigone. RESULTS: New conduction disturbance was seen in 75 of 209 (35.8%) patients. Receiver operating characteristics plots displayed a right fibrous trigone density of −6 Hounsfield unit for SEV and −16 Hounsfield unit for balloon-expandable valve as the optimal cutoff points for prediction conduction disturbance. In multiple regression analyses, the high density of RFT emerged as an independent predictor of conduction disturbance in both the self-expanding valve (odds ratio: 1.01, 95% CI: 1.01 to 1.02, P = 0.035) and balloon-expandable valve (odds ratio: 1.01, 95% CI: 1.01 to 1.03, P = 0.017) groups. A shorter membranous septum length and a greater implantation depth were also found to be significantly associated with a higher incidence of conduction disturbance in both transcatheter aortic valve implantation groups. CONCLUSION: High density of right fibrous trigone is independently associated with conduction disturbance after transcatheter aortic valve implantation, and its pre-procedure computed tomography evaluation can help predict the new-onset of conduction disturbance. Turkish Society of Cardiology 2022-07-01 /pmc/articles/PMC9361055/ /pubmed/35791709 http://dx.doi.org/10.5152/AnatolJCardiol.2022.987 Text en © Copyright 2022 authors https://creativecommons.org/licenses/by-nc/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | Original Investigation Aslan, Serkan Türkvatan, Aysel Topel, Çağdaş Güner, Ahmet Rıza Demir, Ali Kahraman, Serkan Çelik, Ömer Ertürk, Mehmet Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title | Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title_full | Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title_fullStr | Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title_short | Structural Changes of the Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation |
title_sort | structural changes of the right fibrous trigone as a risk factor for conduction disturbance after transcatheter aortic valve implantation |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361055/ https://www.ncbi.nlm.nih.gov/pubmed/35791709 http://dx.doi.org/10.5152/AnatolJCardiol.2022.987 |
work_keys_str_mv | AT aslanserkan structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT turkvatanaysel structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT topelcagdas structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT gunerahmet structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT rızademirali structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT kahramanserkan structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT celikomer structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation AT erturkmehmet structuralchangesoftherightfibroustrigoneasariskfactorforconductiondisturbanceaftertranscatheteraorticvalveimplantation |