Cargando…

Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach

OBJECTIVES: The aim of this study was to simulate different entry points and investigate potential angulation errors of the intramedullary device and resulting changes in the distal femoral cut using a computer-aided design (CAD) approach. MATERIALS AND METHODS: We used a CAD approach to simulate va...

Descripción completa

Detalles Bibliográficos
Autores principales: Stotter, Christoph, Reiter, Erich, Schretter, Werner, Reuter, Philippe, Nehrer, Stefan, Klestil, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361112/
https://www.ncbi.nlm.nih.gov/pubmed/35852187
http://dx.doi.org/10.52312/jdrs.2022.645
_version_ 1784764462017806336
author Stotter, Christoph
Reiter, Erich
Schretter, Werner
Reuter, Philippe
Nehrer, Stefan
Klestil, Thomas
author_facet Stotter, Christoph
Reiter, Erich
Schretter, Werner
Reuter, Philippe
Nehrer, Stefan
Klestil, Thomas
author_sort Stotter, Christoph
collection PubMed
description OBJECTIVES: The aim of this study was to simulate different entry points and investigate potential angulation errors of the intramedullary device and resulting changes in the distal femoral cut using a computer-aided design (CAD) approach. MATERIALS AND METHODS: We used a CAD approach to simulate various distal femoral entry points for intramedullary instrumentation. Simulations were performed on (i) a commercially available three-dimensional (3D) CAD model of a human femur (DigitalFemur) and (ii) a digital 3D model of an analogue large femur model produced using a coordinate measuring machine (FaroFemur). Divergent insertion points medial, lateral, anterior and posterior to the ideal position were simulated. Angulation deviations of the resulting positions of the intramedullary rod were measured and changes in the anatomical-mechanical axis angle were calculated. Differences between the two simulation models were quantified. RESULTS: The ideal entry point in the FaroFemur was 9.9 mm anterior and 4.3 mm medial to the apex of the intercondylar notch, and 9.2 mm anterior and 3.6 mm medial in the DigitalFemur. A medial entry point increased the angle between the anatomical femoral axis and the alignment rod in the FaroFemur and DigitalFemur (with 5 mm displacement 2.510° and 2.363°, respectively; with 10 mm displacement 3.239° and 3.283°, respectively). In contrast, a lateral entry point decreased the angle between the anatomical femoral axis and the alignment rod (with 5 mm displacement 2.267° and 2.262°, respectively; with 10 mm displacement 3.158° and 3.731°, respectively). An anterior entry point changed the angle between the anatomical femoral axis and the alignment rod towards extension (1.802° in the FaroFemur; 2.142° in the DigitalFemur), while a posterior entry point generated a deviation toward flexion (2.045° in the FaroFemur; 2.055° in the DigitalFemur). The mean difference between the two models was 0.108±0.121° with the highest difference for anterior displacement. CONCLUSION: Minor deviations of the entry point for intramedullary instrumentation during total knee arthroplasty can result in malalignment of several degrees.
format Online
Article
Text
id pubmed-9361112
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-93611122022-08-18 Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach Stotter, Christoph Reiter, Erich Schretter, Werner Reuter, Philippe Nehrer, Stefan Klestil, Thomas Jt Dis Relat Surg Original Article OBJECTIVES: The aim of this study was to simulate different entry points and investigate potential angulation errors of the intramedullary device and resulting changes in the distal femoral cut using a computer-aided design (CAD) approach. MATERIALS AND METHODS: We used a CAD approach to simulate various distal femoral entry points for intramedullary instrumentation. Simulations were performed on (i) a commercially available three-dimensional (3D) CAD model of a human femur (DigitalFemur) and (ii) a digital 3D model of an analogue large femur model produced using a coordinate measuring machine (FaroFemur). Divergent insertion points medial, lateral, anterior and posterior to the ideal position were simulated. Angulation deviations of the resulting positions of the intramedullary rod were measured and changes in the anatomical-mechanical axis angle were calculated. Differences between the two simulation models were quantified. RESULTS: The ideal entry point in the FaroFemur was 9.9 mm anterior and 4.3 mm medial to the apex of the intercondylar notch, and 9.2 mm anterior and 3.6 mm medial in the DigitalFemur. A medial entry point increased the angle between the anatomical femoral axis and the alignment rod in the FaroFemur and DigitalFemur (with 5 mm displacement 2.510° and 2.363°, respectively; with 10 mm displacement 3.239° and 3.283°, respectively). In contrast, a lateral entry point decreased the angle between the anatomical femoral axis and the alignment rod (with 5 mm displacement 2.267° and 2.262°, respectively; with 10 mm displacement 3.158° and 3.731°, respectively). An anterior entry point changed the angle between the anatomical femoral axis and the alignment rod towards extension (1.802° in the FaroFemur; 2.142° in the DigitalFemur), while a posterior entry point generated a deviation toward flexion (2.045° in the FaroFemur; 2.055° in the DigitalFemur). The mean difference between the two models was 0.108±0.121° with the highest difference for anterior displacement. CONCLUSION: Minor deviations of the entry point for intramedullary instrumentation during total knee arthroplasty can result in malalignment of several degrees. Bayçınar Medical Publishing 2022-07-06 /pmc/articles/PMC9361112/ /pubmed/35852187 http://dx.doi.org/10.52312/jdrs.2022.645 Text en Copyright © 2022, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Stotter, Christoph
Reiter, Erich
Schretter, Werner
Reuter, Philippe
Nehrer, Stefan
Klestil, Thomas
Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title_full Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title_fullStr Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title_full_unstemmed Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title_short Influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: A computer-aided design approach
title_sort influence of the femoral entry point for intramedullary alignment in total knee arthroplasty: a computer-aided design approach
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361112/
https://www.ncbi.nlm.nih.gov/pubmed/35852187
http://dx.doi.org/10.52312/jdrs.2022.645
work_keys_str_mv AT stotterchristoph influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach
AT reitererich influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach
AT schretterwerner influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach
AT reuterphilippe influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach
AT nehrerstefan influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach
AT klestilthomas influenceofthefemoralentrypointforintramedullaryalignmentintotalkneearthroplastyacomputeraideddesignapproach