Cargando…

The evaluation of a de novo biplanar distal humerus plate: A biomechanical study

OBJECTIVES: The aim of this study was to compare the stability of a novel biplanar distal humerus plate with the single- and doublecolumns J-plating techniques. MATERIALS AND METHODS: Eighteen sawbones humera were divided into three groups. In Groups 1, 2 and 3, biplanar plate, single lateral J-plat...

Descripción completa

Detalles Bibliográficos
Autores principales: Acar, Nihat, Karakaşlı, Ahmet, Gürsan, Onur, Hüsemoğlu, R. Buğra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361113/
https://www.ncbi.nlm.nih.gov/pubmed/35852193
http://dx.doi.org/10.52312/jdrs.2022.604
_version_ 1784764462282047488
author Acar, Nihat
Karakaşlı, Ahmet
Gürsan, Onur
Hüsemoğlu, R. Buğra
author_facet Acar, Nihat
Karakaşlı, Ahmet
Gürsan, Onur
Hüsemoğlu, R. Buğra
author_sort Acar, Nihat
collection PubMed
description OBJECTIVES: The aim of this study was to compare the stability of a novel biplanar distal humerus plate with the single- and doublecolumns J-plating techniques. MATERIALS AND METHODS: Eighteen sawbones humera were divided into three groups. In Groups 1, 2 and 3, biplanar plate, single lateral J-plate and double J-plate, were used, respectively. Transverse osteotomies at the upper portion of the olecranon fossa were made. Blocks of 10-mm was removed from each sample. Axial, torsional, and extensional stiffness of each group were measured. RESULTS: The mean axial stiffness values in Groups 1, 2, and 3 were 64.80±6.75, 33.70±5.71, and 171.48±9.53 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.032), whereas Group 3 showed a statistically significant difference compared to Groups 1 and 2 (p=0.025 and p=0.014, respectively). The mean torsional stiffness values of Groups 1, 2, and 3 were 0.23±0.01, 0.14±0.008, and 0.30±0.007 N/ degree, respectively. Groups 1 and 3 demonstrated a statistically significant difference compared to Group 2 (p=0.042 and p=0.028, respectively). No statistically significant difference was detected between Groups 1 and 3 (p=0.27). The mean extensional bending stiffness values of Groups 1, 2 and 3 were 2.64±0.31, 1.17±0.13, and 3.2±0.1 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.041). There was no statistically significant difference between Groups 1 and 3 (p=0.083). CONCLUSION: Biplanar plate allows applying enough numbers of long sagittal screws and offers more biomechanical stability than lateral column J-plate and in some aspects strong as dual J-plating in torsional and bending tests.
format Online
Article
Text
id pubmed-9361113
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-93611132022-08-18 The evaluation of a de novo biplanar distal humerus plate: A biomechanical study Acar, Nihat Karakaşlı, Ahmet Gürsan, Onur Hüsemoğlu, R. Buğra Jt Dis Relat Surg Original Article OBJECTIVES: The aim of this study was to compare the stability of a novel biplanar distal humerus plate with the single- and doublecolumns J-plating techniques. MATERIALS AND METHODS: Eighteen sawbones humera were divided into three groups. In Groups 1, 2 and 3, biplanar plate, single lateral J-plate and double J-plate, were used, respectively. Transverse osteotomies at the upper portion of the olecranon fossa were made. Blocks of 10-mm was removed from each sample. Axial, torsional, and extensional stiffness of each group were measured. RESULTS: The mean axial stiffness values in Groups 1, 2, and 3 were 64.80±6.75, 33.70±5.71, and 171.48±9.53 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.032), whereas Group 3 showed a statistically significant difference compared to Groups 1 and 2 (p=0.025 and p=0.014, respectively). The mean torsional stiffness values of Groups 1, 2, and 3 were 0.23±0.01, 0.14±0.008, and 0.30±0.007 N/ degree, respectively. Groups 1 and 3 demonstrated a statistically significant difference compared to Group 2 (p=0.042 and p=0.028, respectively). No statistically significant difference was detected between Groups 1 and 3 (p=0.27). The mean extensional bending stiffness values of Groups 1, 2 and 3 were 2.64±0.31, 1.17±0.13, and 3.2±0.1 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.041). There was no statistically significant difference between Groups 1 and 3 (p=0.083). CONCLUSION: Biplanar plate allows applying enough numbers of long sagittal screws and offers more biomechanical stability than lateral column J-plate and in some aspects strong as dual J-plating in torsional and bending tests. Bayçınar Medical Publishing 2022-07-06 /pmc/articles/PMC9361113/ /pubmed/35852193 http://dx.doi.org/10.52312/jdrs.2022.604 Text en Copyright © 2022, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Acar, Nihat
Karakaşlı, Ahmet
Gürsan, Onur
Hüsemoğlu, R. Buğra
The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title_full The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title_fullStr The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title_full_unstemmed The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title_short The evaluation of a de novo biplanar distal humerus plate: A biomechanical study
title_sort evaluation of a de novo biplanar distal humerus plate: a biomechanical study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361113/
https://www.ncbi.nlm.nih.gov/pubmed/35852193
http://dx.doi.org/10.52312/jdrs.2022.604
work_keys_str_mv AT acarnihat theevaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT karakaslıahmet theevaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT gursanonur theevaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT husemoglurbugra theevaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT acarnihat evaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT karakaslıahmet evaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT gursanonur evaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy
AT husemoglurbugra evaluationofadenovobiplanardistalhumerusplateabiomechanicalstudy