Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
This pilot study of ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. PURPOSE: To evaluate the intraocular pressure (IOP)–lowering effect o...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9362344/ https://www.ncbi.nlm.nih.gov/pubmed/35773233 http://dx.doi.org/10.1097/IJG.0000000000002070 |
Sumario: | This pilot study of ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. PURPOSE: To evaluate the intraocular pressure (IOP)–lowering effect of gel microstent (XEN Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. PATIENTS AND METHODS: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. At postoperative visit, the IOP, the number of glaucoma medications, the final position of the stent, and the needling rate were analyzed. Assessments were conducted 1 day, 1 week and 1, 3, 6, and 12 months after the implantation. Treatment success was defined as IOP ≥6 mm Hg and ≤18 mm Hg with ≥20% reduction from presurgical IOP, with or without medications. RESULTS: Thirty-four eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mm Hg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mm Hg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after 1 attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber reformation. Adjunctive needling was required in 21% of implanted eyes. CONCLUSION: Slit-lamp-based transconjunctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotony among other adverse events. |
---|