Cargando…

Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study

This pilot study of ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. PURPOSE: To evaluate the intraocular pressure (IOP)–lowering effect o...

Descripción completa

Detalles Bibliográficos
Autores principales: Gagné, Sébastien, Yuen, Darana, Cohen, Shawn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9362344/
https://www.ncbi.nlm.nih.gov/pubmed/35773233
http://dx.doi.org/10.1097/IJG.0000000000002070
_version_ 1784764707692871680
author Gagné, Sébastien
Yuen, Darana
Cohen, Shawn
author_facet Gagné, Sébastien
Yuen, Darana
Cohen, Shawn
author_sort Gagné, Sébastien
collection PubMed
description This pilot study of ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. PURPOSE: To evaluate the intraocular pressure (IOP)–lowering effect of gel microstent (XEN Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. PATIENTS AND METHODS: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. At postoperative visit, the IOP, the number of glaucoma medications, the final position of the stent, and the needling rate were analyzed. Assessments were conducted 1 day, 1 week and 1, 3, 6, and 12 months after the implantation. Treatment success was defined as IOP ≥6 mm Hg and ≤18 mm Hg with ≥20% reduction from presurgical IOP, with or without medications. RESULTS: Thirty-four eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mm Hg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mm Hg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after 1 attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber reformation. Adjunctive needling was required in 21% of implanted eyes. CONCLUSION: Slit-lamp-based transconjunctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotony among other adverse events.
format Online
Article
Text
id pubmed-9362344
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-93623442022-08-11 Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study Gagné, Sébastien Yuen, Darana Cohen, Shawn J Glaucoma Celebrating 30 Years of the Journal of Glaucoma: Original Studies This pilot study of ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. PURPOSE: To evaluate the intraocular pressure (IOP)–lowering effect of gel microstent (XEN Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. PATIENTS AND METHODS: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. At postoperative visit, the IOP, the number of glaucoma medications, the final position of the stent, and the needling rate were analyzed. Assessments were conducted 1 day, 1 week and 1, 3, 6, and 12 months after the implantation. Treatment success was defined as IOP ≥6 mm Hg and ≤18 mm Hg with ≥20% reduction from presurgical IOP, with or without medications. RESULTS: Thirty-four eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mm Hg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mm Hg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after 1 attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber reformation. Adjunctive needling was required in 21% of implanted eyes. CONCLUSION: Slit-lamp-based transconjunctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotony among other adverse events. Lippincott Williams & Wilkins 2022-08 2022-06-30 /pmc/articles/PMC9362344/ /pubmed/35773233 http://dx.doi.org/10.1097/IJG.0000000000002070 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Celebrating 30 Years of the Journal of Glaucoma: Original Studies
Gagné, Sébastien
Yuen, Darana
Cohen, Shawn
Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title_full Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title_fullStr Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title_full_unstemmed Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title_short Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
title_sort transconjunctival xen45 implantation for glaucoma performed at the slit lamp: a pilot study
topic Celebrating 30 Years of the Journal of Glaucoma: Original Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9362344/
https://www.ncbi.nlm.nih.gov/pubmed/35773233
http://dx.doi.org/10.1097/IJG.0000000000002070
work_keys_str_mv AT gagnesebastien transconjunctivalxen45implantationforglaucomaperformedattheslitlampapilotstudy
AT yuendarana transconjunctivalxen45implantationforglaucomaperformedattheslitlampapilotstudy
AT cohenshawn transconjunctivalxen45implantationforglaucomaperformedattheslitlampapilotstudy