Cargando…
Negative Outcome Following Systemic Alteplase Administration Prior to Extracorporeal Membrane Oxygenation in a Kidney Transplant Patient With Cardiac Arrest: A Case Report
A case of a negative outcome following systemic alteplase administration prior to extracorporeal membrane oxygenation (ECMO) in a kidney transplant patient with cardiac arrest is reported. A patient status-post kidney transplantation was admitted to the surgical intensive care unit (ICU) and experie...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9365663/ https://www.ncbi.nlm.nih.gov/pubmed/35974803 http://dx.doi.org/10.14740/jocmr4744 |
Sumario: | A case of a negative outcome following systemic alteplase administration prior to extracorporeal membrane oxygenation (ECMO) in a kidney transplant patient with cardiac arrest is reported. A patient status-post kidney transplantation was admitted to the surgical intensive care unit (ICU) and experienced cardiac arrest after developing sudden-onset chest pain and shortness of breath. During cardiopulmonary resuscitation, alteplase 50 mg was administered intravenous push for suspected pulmonary embolism (PE) before the patient was evaluated for and started on veno-arterial ECMO. Within several hours, cardiopulmonary resuscitation needed to be reinitiated. Ultimately, the decision was made to cede further resuscitation efforts due to futility. A post-mortem examination included an immediate cause of death of acute myocardial infarction with extensive retroperitoneal hemorrhage. The role of ECMO is emerging in cardiac arrest, and should be considered as a management option before the administration of systemic thrombolysis in patients with increased bleeding risk. |
---|