Cargando…

Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis

The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searc...

Descripción completa

Detalles Bibliográficos
Autores principales: Patro, Swadheena, Meto, Agron, Mohanty, Ankita, Chopra, Viresh, Miglani, Sanjay, Das, Antarikshya, Luke, Alexander Maniangat, Hadi, Dunia Al, Meto, Aida, Fiorillo, Luca, Karobari, Mohmed Isaqali, Wahjuningrum, Dian Agustin, Pawar, Ajinkya M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9367848/
https://www.ncbi.nlm.nih.gov/pubmed/35954958
http://dx.doi.org/10.3390/ijerph19159599
_version_ 1784765936542154752
author Patro, Swadheena
Meto, Agron
Mohanty, Ankita
Chopra, Viresh
Miglani, Sanjay
Das, Antarikshya
Luke, Alexander Maniangat
Hadi, Dunia Al
Meto, Aida
Fiorillo, Luca
Karobari, Mohmed Isaqali
Wahjuningrum, Dian Agustin
Pawar, Ajinkya M.
author_facet Patro, Swadheena
Meto, Agron
Mohanty, Ankita
Chopra, Viresh
Miglani, Sanjay
Das, Antarikshya
Luke, Alexander Maniangat
Hadi, Dunia Al
Meto, Aida
Fiorillo, Luca
Karobari, Mohmed Isaqali
Wahjuningrum, Dian Agustin
Pawar, Ajinkya M.
author_sort Patro, Swadheena
collection PubMed
description The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
format Online
Article
Text
id pubmed-9367848
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93678482022-08-12 Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis Patro, Swadheena Meto, Agron Mohanty, Ankita Chopra, Viresh Miglani, Sanjay Das, Antarikshya Luke, Alexander Maniangat Hadi, Dunia Al Meto, Aida Fiorillo, Luca Karobari, Mohmed Isaqali Wahjuningrum, Dian Agustin Pawar, Ajinkya M. Int J Environ Res Public Health Systematic Review The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status. MDPI 2022-08-04 /pmc/articles/PMC9367848/ /pubmed/35954958 http://dx.doi.org/10.3390/ijerph19159599 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Patro, Swadheena
Meto, Agron
Mohanty, Ankita
Chopra, Viresh
Miglani, Sanjay
Das, Antarikshya
Luke, Alexander Maniangat
Hadi, Dunia Al
Meto, Aida
Fiorillo, Luca
Karobari, Mohmed Isaqali
Wahjuningrum, Dian Agustin
Pawar, Ajinkya M.
Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title_full Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title_fullStr Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title_full_unstemmed Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title_short Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
title_sort diagnostic accuracy of pulp vitality tests and pulp sensibility tests for assessing pulpal health in permanent teeth: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9367848/
https://www.ncbi.nlm.nih.gov/pubmed/35954958
http://dx.doi.org/10.3390/ijerph19159599
work_keys_str_mv AT patroswadheena diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT metoagron diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT mohantyankita diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT chopraviresh diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT miglanisanjay diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT dasantarikshya diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT lukealexandermaniangat diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT hadiduniaal diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT metoaida diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT fiorilloluca diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT karobarimohmedisaqali diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT wahjuningrumdianagustin diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis
AT pawarajinkyam diagnosticaccuracyofpulpvitalitytestsandpulpsensibilitytestsforassessingpulpalhealthinpermanentteethasystematicreviewandmetaanalysis