Cargando…

A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow

The thermal measurement sensor applied to hypersonic vehicles requires characteristic size in the order of micrometers and characteristic time in the order of microseconds. The measurement criteria of localized detection, high temporal-spatial precision, and long-term stability cannot all be reached...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Xuwen, Wang, Haidong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9369755/
https://www.ncbi.nlm.nih.gov/pubmed/35955320
http://dx.doi.org/10.3390/ma15155385
_version_ 1784766568667807744
author Luo, Xuwen
Wang, Haidong
author_facet Luo, Xuwen
Wang, Haidong
author_sort Luo, Xuwen
collection PubMed
description The thermal measurement sensor applied to hypersonic vehicles requires characteristic size in the order of micrometers and characteristic time in the order of microseconds. The measurement criteria of localized detection, high temporal-spatial precision, and long-term stability cannot all be reached by current thermal measuring techniques. This work presents a temperature sensor with excellent temporal-spatial resolution that can measure both in-plane and out-of-plane heat flow. The sensor was made of thin platinum nano-film and an aluminum nitride ceramic sheet. The sensor was calibrated using a thermostatic vacuum chamber and used for in-plane and out-of-plane heat flow measurements. The temperature measurement accuracy of the sensor was estimated to be 0.01 K. The sensor’s resolution for measuring heat flow density is more than 500 W/m(2) and its measurement uncertainty is roughly 3%. To ensure the structural stability of the device, the aluminum nitride ceramic sheet was chosen as the substrate of the thermal sensing unit, and the response time became longer due to the high thermal conductivity of aluminum nitride. The suspension platinum nano-film sensor can reach a sub-microsecond response time according to the theoretical derivation. Experimental results of pneumatic thermal effects of high-temperature flames using the sensor prove that the designed sensor has good sensitivity and accuracy.
format Online
Article
Text
id pubmed-9369755
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93697552022-08-12 A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow Luo, Xuwen Wang, Haidong Materials (Basel) Article The thermal measurement sensor applied to hypersonic vehicles requires characteristic size in the order of micrometers and characteristic time in the order of microseconds. The measurement criteria of localized detection, high temporal-spatial precision, and long-term stability cannot all be reached by current thermal measuring techniques. This work presents a temperature sensor with excellent temporal-spatial resolution that can measure both in-plane and out-of-plane heat flow. The sensor was made of thin platinum nano-film and an aluminum nitride ceramic sheet. The sensor was calibrated using a thermostatic vacuum chamber and used for in-plane and out-of-plane heat flow measurements. The temperature measurement accuracy of the sensor was estimated to be 0.01 K. The sensor’s resolution for measuring heat flow density is more than 500 W/m(2) and its measurement uncertainty is roughly 3%. To ensure the structural stability of the device, the aluminum nitride ceramic sheet was chosen as the substrate of the thermal sensing unit, and the response time became longer due to the high thermal conductivity of aluminum nitride. The suspension platinum nano-film sensor can reach a sub-microsecond response time according to the theoretical derivation. Experimental results of pneumatic thermal effects of high-temperature flames using the sensor prove that the designed sensor has good sensitivity and accuracy. MDPI 2022-08-05 /pmc/articles/PMC9369755/ /pubmed/35955320 http://dx.doi.org/10.3390/ma15155385 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Luo, Xuwen
Wang, Haidong
A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title_full A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title_fullStr A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title_full_unstemmed A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title_short A High Temporal-Spatial Resolution Temperature Sensor for Simultaneous Measurement of Anisotropic Heat Flow
title_sort high temporal-spatial resolution temperature sensor for simultaneous measurement of anisotropic heat flow
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9369755/
https://www.ncbi.nlm.nih.gov/pubmed/35955320
http://dx.doi.org/10.3390/ma15155385
work_keys_str_mv AT luoxuwen ahightemporalspatialresolutiontemperaturesensorforsimultaneousmeasurementofanisotropicheatflow
AT wanghaidong ahightemporalspatialresolutiontemperaturesensorforsimultaneousmeasurementofanisotropicheatflow
AT luoxuwen hightemporalspatialresolutiontemperaturesensorforsimultaneousmeasurementofanisotropicheatflow
AT wanghaidong hightemporalspatialresolutiontemperaturesensorforsimultaneousmeasurementofanisotropicheatflow