Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis

Background: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the ballo...

Descripción completa

Detalles Bibliográficos
Autores principales: Potratz, Max, Mohemed, Kawa, Omran, Hazem, Gortamashvili, Lasha, Friedrichs, Kai Peter, Scholtz, Werner, Scholtz, Smita, Rudolph, Volker, Piper, Cornelia, Gilis-Januszewski, Tomasz, Schramm, René, Furukawa, Nobuyuki, Gummert, Jan, Bleiziffer, Sabine, Rudolph, Tanja Katharina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9369986/
https://www.ncbi.nlm.nih.gov/pubmed/35956185
http://dx.doi.org/10.3390/jcm11154570
_version_ 1784766648382652416
author Potratz, Max
Mohemed, Kawa
Omran, Hazem
Gortamashvili, Lasha
Friedrichs, Kai Peter
Scholtz, Werner
Scholtz, Smita
Rudolph, Volker
Piper, Cornelia
Gilis-Januszewski, Tomasz
Schramm, René
Furukawa, Nobuyuki
Gummert, Jan
Bleiziffer, Sabine
Rudolph, Tanja Katharina
author_facet Potratz, Max
Mohemed, Kawa
Omran, Hazem
Gortamashvili, Lasha
Friedrichs, Kai Peter
Scholtz, Werner
Scholtz, Smita
Rudolph, Volker
Piper, Cornelia
Gilis-Januszewski, Tomasz
Schramm, René
Furukawa, Nobuyuki
Gummert, Jan
Bleiziffer, Sabine
Rudolph, Tanja Katharina
author_sort Potratz, Max
collection PubMed
description Background: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. Methods: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. Results: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. Conclusions: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.
format Online
Article
Text
id pubmed-9369986
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93699862022-08-12 Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis Potratz, Max Mohemed, Kawa Omran, Hazem Gortamashvili, Lasha Friedrichs, Kai Peter Scholtz, Werner Scholtz, Smita Rudolph, Volker Piper, Cornelia Gilis-Januszewski, Tomasz Schramm, René Furukawa, Nobuyuki Gummert, Jan Bleiziffer, Sabine Rudolph, Tanja Katharina J Clin Med Article Background: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. Methods: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. Results: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. Conclusions: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design. MDPI 2022-08-05 /pmc/articles/PMC9369986/ /pubmed/35956185 http://dx.doi.org/10.3390/jcm11154570 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Potratz, Max
Mohemed, Kawa
Omran, Hazem
Gortamashvili, Lasha
Friedrichs, Kai Peter
Scholtz, Werner
Scholtz, Smita
Rudolph, Volker
Piper, Cornelia
Gilis-Januszewski, Tomasz
Schramm, René
Furukawa, Nobuyuki
Gummert, Jan
Bleiziffer, Sabine
Rudolph, Tanja Katharina
Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title_full Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title_fullStr Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title_full_unstemmed Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title_short Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
title_sort hemodynamic performance of two current-generation transcatheter heart valve prostheses in severely calcified aortic valve stenosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9369986/
https://www.ncbi.nlm.nih.gov/pubmed/35956185
http://dx.doi.org/10.3390/jcm11154570
work_keys_str_mv AT potratzmax hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT mohemedkawa hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT omranhazem hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT gortamashvililasha hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT friedrichskaipeter hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT scholtzwerner hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT scholtzsmita hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT rudolphvolker hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT pipercornelia hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT gilisjanuszewskitomasz hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT schrammrene hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT furukawanobuyuki hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT gummertjan hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT bleiziffersabine hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis
AT rudolphtanjakatharina hemodynamicperformanceoftwocurrentgenerationtranscatheterheartvalveprosthesesinseverelycalcifiedaorticvalvestenosis