Cargando…
Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate
In this paper, we examine the development of the estimation models of bond strength and effective bond length for a double strap joint between carbon fiber reinforced polymer (CFRP) plate and corroded steel plate. The experimental study on the bond behavior between CFRP plate and corroded steel plat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370091/ https://www.ncbi.nlm.nih.gov/pubmed/35956583 http://dx.doi.org/10.3390/polym14153069 |
_version_ | 1784766682379583488 |
---|---|
author | Li, Anbang Wang, Hao Li, Han Kong, Deliang Xu, Shanhua |
author_facet | Li, Anbang Wang, Hao Li, Han Kong, Deliang Xu, Shanhua |
author_sort | Li, Anbang |
collection | PubMed |
description | In this paper, we examine the development of the estimation models of bond strength and effective bond length for a double strap joint between carbon fiber reinforced polymer (CFRP) plate and corroded steel plate. The experimental study on the bond behavior between CFRP plate and corroded steel plate is summarized first and the analytical interfacial bond–slip model for CFRP plate externally bonded to corroded steel plate is proposed. Based on the theoretical stress analysis for the CFRP plate–corroded steel plate double-lap joint, the piecewise expressions of the interfacial shear stress and the normal peel stress of the interface between CFRP plate and corroded steel plate were established. The estimation models of the bond strength and the effective bond length for the double strap joint between the CFRP plate and the corroded steel plate were consequently developed on the basis of interfacial stress distribution equations and the stress boundary conditions. The comparison between the predicted and experimental results indicated that the proposed models could be adopted to predict the bond strength and effective bond length for the CFRP plates externally bonded to corroded steel substrates with reasonable accuracy. The proposed estimation models are expected to provide meaningful references and essential data for the reliable application of CFRP strengthening system to the performance improvement of corroded steel structures. |
format | Online Article Text |
id | pubmed-9370091 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93700912022-08-12 Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate Li, Anbang Wang, Hao Li, Han Kong, Deliang Xu, Shanhua Polymers (Basel) Article In this paper, we examine the development of the estimation models of bond strength and effective bond length for a double strap joint between carbon fiber reinforced polymer (CFRP) plate and corroded steel plate. The experimental study on the bond behavior between CFRP plate and corroded steel plate is summarized first and the analytical interfacial bond–slip model for CFRP plate externally bonded to corroded steel plate is proposed. Based on the theoretical stress analysis for the CFRP plate–corroded steel plate double-lap joint, the piecewise expressions of the interfacial shear stress and the normal peel stress of the interface between CFRP plate and corroded steel plate were established. The estimation models of the bond strength and the effective bond length for the double strap joint between the CFRP plate and the corroded steel plate were consequently developed on the basis of interfacial stress distribution equations and the stress boundary conditions. The comparison between the predicted and experimental results indicated that the proposed models could be adopted to predict the bond strength and effective bond length for the CFRP plates externally bonded to corroded steel substrates with reasonable accuracy. The proposed estimation models are expected to provide meaningful references and essential data for the reliable application of CFRP strengthening system to the performance improvement of corroded steel structures. MDPI 2022-07-29 /pmc/articles/PMC9370091/ /pubmed/35956583 http://dx.doi.org/10.3390/polym14153069 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Anbang Wang, Hao Li, Han Kong, Deliang Xu, Shanhua Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title | Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title_full | Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title_fullStr | Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title_full_unstemmed | Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title_short | Estimation of Bond Strength and Effective Bond Length for the Double Strap Joint between Carbon Fiber Reinforced Polymer (CFRP) Plate and Corroded Steel Plate |
title_sort | estimation of bond strength and effective bond length for the double strap joint between carbon fiber reinforced polymer (cfrp) plate and corroded steel plate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370091/ https://www.ncbi.nlm.nih.gov/pubmed/35956583 http://dx.doi.org/10.3390/polym14153069 |
work_keys_str_mv | AT lianbang estimationofbondstrengthandeffectivebondlengthforthedoublestrapjointbetweencarbonfiberreinforcedpolymercfrpplateandcorrodedsteelplate AT wanghao estimationofbondstrengthandeffectivebondlengthforthedoublestrapjointbetweencarbonfiberreinforcedpolymercfrpplateandcorrodedsteelplate AT lihan estimationofbondstrengthandeffectivebondlengthforthedoublestrapjointbetweencarbonfiberreinforcedpolymercfrpplateandcorrodedsteelplate AT kongdeliang estimationofbondstrengthandeffectivebondlengthforthedoublestrapjointbetweencarbonfiberreinforcedpolymercfrpplateandcorrodedsteelplate AT xushanhua estimationofbondstrengthandeffectivebondlengthforthedoublestrapjointbetweencarbonfiberreinforcedpolymercfrpplateandcorrodedsteelplate |